Merge pull request #389 from rordenlab/development
Browse files Browse the repository at this point in the history
Development
  • Loading branch information
neurolabusc authored Mar 31, 2020
2 parents f54be46 + ab26453 commit 110dc88
Show file tree
Hide file tree
Showing 17 changed files with 1,089 additions and 274 deletions.
3 changes: 2 additions & 1 deletion .travis.yml
Original file line number Diff line number Diff line change
Expand Up @@ -27,7 +27,8 @@ before_install:
- git submodule update --init --depth=3 dcm_qa_uih

script:
- mkdir build && cd build && cmake -DBATCH_VERSION=ON -DUSE_OPENJPEG=ON -DUSE_JPEGLS=true -DZLIB_IMPLEMENTATION=Cloudflare .. && make && cd -
# - mkdir build && cd build && cmake -DBATCH_VERSION=ON -DUSE_OPENJPEG=ON -DUSE_JPEGLS=true -DZLIB_IMPLEMENTATION=Cloudflare .. && make && cd -
- mkdir build && cd build && cmake -DBATCH_VERSION=OFF -DUSE_OPENJPEG=ON -DUSE_JPEGLS=true -DZLIB_IMPLEMENTATION=Cloudflare .. && make && cd -
- export PATH=$PWD/build/bin:$PATH
- cd dcm_qa && ./batch.sh && cd -
- cd dcm_qa_nih && ./batch.sh && cd -
Expand Down
32 changes: 23 additions & 9 deletions FILENAMING.md
Original file line number Diff line number Diff line change
Expand Up @@ -13,34 +13,46 @@ You request the output file name with the `-f` argument. For example, consider y
- %e=echo number (from 0018,0086)
- %f=folder name (name of folder containing first DICOM)
- %i=ID of patient (from 0010,0020)
- %j=seriesInstanceUID (from 0020,000E)
- %k=studyInstanceUID (from 0020,000D)
- %j=series instance UID (from 0020,000E)
- %k=study instance UID (from 0020,000D)
- %l=local procedure step description (from 0040,0254)
- %m=manufacturer short name (from 0008,0070: GE, Ph, Si, To, UI, NA)
- %n=name of patient (from 0010,0010)
- %o=mediaObjectInstanceUID (0002,0003)*
- %p=protocol name (from 0018,1030)
- %r=instance number (from 0020,0013)
- %r=instance number (from 0020,0013)*
- %s=series number (from 0020,0011)
- %t=time of study (from 0008,0020 and 0008,0030)
- %u=acquisition number (from 0020,0012)
- %v=vendor long name (from 0008,0070: GE, Philips, Siemens, Toshiba, UIH, NA)
- %x=study ID (from 0020,0010)
- %y=youth in series: GE RawDataRunNumber ([0019,10A2](https://github.com/rordenlab/dcm2niix/issues/359)) else TemporalPosition ([0020,0100](https://github.com/rordenlab/dcm2niix/issues/357))*
- %z=sequence name (from 0018,0024)

* Attributes listed above with an asterisk (*) are likely to vary within a series, and are typically not useful for DICOM to NIfTI conversion (where all images from a series are stacked together). These attributes can be useful for [renaming](RENAMING.md) DICOM images

## File Name Post-fixes: Image Disambiguation

In general dcm2niix creates images with 3D dimensions, or 4 dimensions when the 4th dimension is time (fMRI) or gradient number (DWI). It will use the following extensions to disambiguate additional dimensions from the same series:
In general dcm2niix creates images with 3D dimensions, or 4 dimensions when the 4th dimension is time (fMRI) or gradient number (DWI). However, DICOM images can include additional dimensions, e.g. a multiple-echo sequence would generate separate images for each echo. By default dcm2niix will use the following extensions to the file names in order to disambiguate additional dimensions from the same series:

- _cNx.._cNz where C* refers to the coil name (typically only seen for uncombined data, where a separate image is generated for each antenna)
- _e1..eN echo number for multi-echo sequences
- _Eq is commonly seen in [CT scans](https://github.com/neurolabusc/dcm_qa_ct). For example, CT scans of the brain often have many slices closely packed near the brain stem and only a few slices spread far apart near the top of the head. Variable between-slice spacing is rarer in MRI, and if you see this from a MRI sequence you should ensure that [all of the acquired slices have been provided to dcm2niix](https://neurostars.org/t/field-mapping-siemens-scanners-dcm2niix-output-2-bids/2075/7). NIfTI asumes all 2D slices that form a 3D stack are equidistant. Therefore, dcm2niix reslices the input data to generate an equidistant volume.
- _ph phase map
- _iN appended image number for non-parallel slices
- _imaginary imaginary component of complex image
- _MoCo is appended to the ProtocolName if Image Type (0008,0008) includes the term 'MOCO'. This helps disambiguate Siemens fMRI runs where both motion corrected and raw data is stored for a single session.
- _real real component of complex image
- _phMag rare case where phase and magnitude are saved as the 4th dimension
- _t If the trigger delay time (0020,9153 or 0018,1060) is non-zero, it will be recorded in the file name. For example, the files "T1_t178.nii" and "T1_t511" suggests that the T1 scan was acquired with two cardiac trigger delays (178 and 511ms after the last R-peak).
- _ADC Philips specific case. A DWI image where derived isotropic, ADC or trace volume was appended to the series. Since this image will disrupt subsequent processing, and because subsequent processing (dwidenoise, topup, eddy) will yield better derived images, dcm2niix will also create an additional image without this volume. Therefore, the _ADC file should typically be discarded. If you want dcm2niix to discard these useless derived images, use the ignore feature ('-i y').
- _Eq is specific to [CT scans](https://www.nitrc.org/plugins/mwiki/index.php/dcm2nii:MainPage#Computed_Tomography_.28CT.2C_CAT.29). These scans can be acquired with variable distance between the slices of a 3D volume. NIfTI asumes all 2D slices that form a 3D stack are equidistant. Therefore, dcm2niix reslices the input data to generate an equidistant volume.
- _t If the trigger delay time (0020,9153) or trigger time (0018,1060) is non-zero, it will be recorded in the file name. For example, the files "T1_t178.nii" and "T1_t511" suggests that the T1 scan was acquired with two cardiac trigger delays (178 and 511ms after the last R-peak).
- _Tilt is specific to [CT scans](https://www.nitrc.org/plugins/mwiki/index.php/dcm2nii:MainPage#Computed_Tomography_.28CT.2C_CAT.29). These scans can be acquired with a gantry tilt that causes a skew that can not be stored in a NIfTI qForm. Therefore, the slices are resampled to remove the effect of tilt.
- _MoCo is appended to the ProtocolName if Image Type (0008,0008) includes the term 'MOCO'. This helps disambiguate Siemens fMRI runs where both motion corrected and raw data is stored for a single session.

Some post-fixes are specific to Philips DICOMs
- _ADC Philips specific case. A DWI image where derived isotropic, ADC or trace volume was appended to the series. Since this image will disrupt subsequent processing, and because subsequent processing (dwidenoise, topup, eddy) will yield better derived images, dcm2niix will also create an additional image without this volume. Therefore, the _ADC file should typically be discarded. If you want dcm2niix to discard these useless derived images, use the ignore feature ('-i y').
- _Raw Philips XX_* DICOMs (Raw Data Storage).
- _PS Philips PS_* DICOMs (Grayscale Softcopy Presentation State).

If you do not want post-fixes, run dcm2niix in the terse mode (`--terse`). In this mode, most post-fixes will be omitted. Beware that this mode can have name clashes, and images from a series may over write each other.

## File Name Conflicts

Expand All @@ -64,4 +76,6 @@ dcm2niix will attempt to write your image using the naming scheme you specify wi
| (vertical bar or pipe)
? (question mark)
* (asterisk)
```
```

Be warned that dcm2niix will copy all allowed characters verbatim, which can cause problems for some other tools. Consider this [sample dataset](https://github.com/neurolabusc/dcm_qa_nih/tree/master/In/20180918GE/mr_0004) where the DICOM Protocol Name (0018,1030) is 'Axial_EPI-FMRI_(Interleaved_I_to_S)'. The parentheses ("round brackets") may cause other tools issues. Consider converting this series with the command 'dcm2niix -f %s_%p ~/DICOM' to create the file '4_Axial_EPI-FMRI_(Interleaved_I_to_S).nii'.If you now run the command 'fslhd 4_Axial_EPI-FMRI_(Interleaved_I_to_S).nii' you will get the error '-bash: syntax error near unexpected token `(''. Therefore, it is often a good idea to use double quotes to specify the names of files. In this example 'fslhd "4_Axial_EPI-FMRI_(Interleaved_I_to_S).nii"' will work correctly.
12 changes: 11 additions & 1 deletion GE/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -20,6 +20,15 @@ If neither Trigger Time (DICOM 0018,1060) or RTIA Timer (0021,105E) store slice

This private element of the DICOM header is used to determine the phase encoding polarity. Specifically, we need to know the "Ky traversal direction" (top-down, or bottom up) and the phase encoding polarity. Unfortunately, this data is stored in a complicated, proprietary structure, that has changed with different releases of GE software. [Click here to see the definition for this structure](https://github.com/ScottHaileRobertson/GE-MRI-Tools/blob/master/GePackage/%2BGE/%2BPfile/%2BHeader/%2BRDB15/rdbm.h).

## Multi-Echo EPI Sequences

Current GE software (DV26.0_R03_1831.b) running research multi-echo sequences create invalid DICOM images. The required public [EchoTime (0018,0081)](https://dicom.innolitics.com/ciods/mr-image/mr-image/00180081) attribute lists the shortest echo time for the series, rather than the actual echo time for the given DICOM image. The public tag [EchoNumber (0018,0086)](https://dicom.innolitics.com/ciods/mr-image/mr-image/00180086) reports `1` for all echoes. These limitations in GE's DICOM images disrupt dcm2niix's image conversion. Hopefully future product sequences will generate valid DICOM data. In the meantime, [issue 359](https://github.com/rordenlab/dcm2niix/issues/359) provides a kludge for image conversion.


## Imkage Interpolation

Some sequences allow the user to interpolate images in plane (e.g. saving a 2D 64x64 EPI image as 128x128) or between slices (e.g. saving a 126 slice T1-weighted image as 252 images). The resulting files require much more disk space, add no new information, are slower to process and can [disrupt some tools](https://mrtrix.readthedocs.io/en/latest/reference/commands/mrdegibbs.html). Users are strongly discouraged from interpolating raw data. However, dcm2niix should correctly detect this interpolation, resolving apparent discrepancies between tags (0020,1002; 0021,104F; 0054,0081). [Issue 355](https://github.com/rordenlab/dcm2niix/issues/355) provides details.

## Total Readout Time

One often wants to determine [echo spacing, bandwidth](https://support.brainvoyager.com/brainvoyager/functional-analysis-preparation/29-pre-processing/78-epi-distortion-correction-echo-spacing-and-bandwidth) and total read-out time for EPI data so they can be undistorted. Total readout time is influence by parallel acceleration factor, bandwidth, number of EPI lines, and partial Fourier. Not all of these parameters are available from the GE DICOM images, so a user needs to check the scanner console.
Expand All @@ -35,5 +44,6 @@ In addition to the public DICOM tags, previous versions of dcm2niix attempted to
## Sample Datasets

- [A validation dataset for dcm2niix commits](https://github.com/neurolabusc/dcm_qa_nih).
- [Slice timing validation](https://github.com/neurolabusc/dcm_qa_stc) for different varieties of GE EPI sequences.
- [Examples of phase encoding polarity, slice timing and diffusion gradients](https://github.com/nikadon/cc-dcm2bids-wrapper/tree/master/dicom-qa-examples/).
- The dcm2niix (wiki)[https://www.nitrc.org/plugins/mwiki/index.php/dcm2nii:MainPage] includes examples of diffusion data, slice timing, and other variations.
- The dcm2niix [wiki](https://www.nitrc.org/plugins/mwiki/index.php/dcm2nii:MainPage) includes examples of diffusion data, slice timing, and other variations.
26 changes: 24 additions & 2 deletions Philips/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -72,15 +72,37 @@ Private Tags

For modern Philips DICOMs, the current version of dcm2niix uses Dimension Index Values (0020,9157) to determine gradient number, which can also be found in (2005,1413). However, while 2005,1413 is always indexed from one, this is not necessarily the case for 0020,9157. For example, the ADNI DWI dataset for participant 018_S_4868 has values of 2005,1413 that range from 1..36 for the 36 directions, while 0020,9157 ranges from 2..37. The current version of dcm2niix compensates for this by re-indexing the values of 0020,9157 after all the volumes have been read.

For acquiring DWI data, you can adjust your setup with from the Philips console. Specifically, in Contrast one selects Diffusion mode to DTI and adjusts the directional resolution. Options for directional resolution are `Low` which acquires 6 directions (P,M,S, plus 3 oblique), `Medium` (15 directions), `High` (32 directions) and `Opt x` where x is a number from 6 - 128 directions. DTI Elite users can also select `From File`. This will import the text file named E:\Export\dti_vectors_input.txt. This text file has a simple format. The first line is optional and is the name of the scheme - this line should not begin with a number. If the file contains a b=0 vector, it must be the first line of the file. The following lines specify the direction and bvalues. If you want to acquire more than one b=0 volume, each must specify a unique direction. One can only process these custom files with Philips FiberTrak if the same directions have been obtained for all b-values. Here is an example file that obeys these rules:

```
MyCustomDirections
0.000 0.000 1.000 0
0.049 -0.919 -0.391 1000
0.726 0.301 -0.618 1000
-0.683 0.255 -0.684 1000
0.845 -0.502 -0.186 1000
-0.73 -0.619 -0.288 1000
-0.051 0.039 0.998 1000
-0.018 0.871 -0.491 1000
-0.444 0.494 0.747 1000
-0.989 -0.086 -0.116 1000
1.000 0.000 0.000 0
```

## Missing Information.

Philips DICOMs do not contain all the information desired by many neuroscientists. Due to this, the [BIDS](http://bids.neuroimaging.io/) files created by dcm2niix are impoverished relative to data from other vendors. This reflects a limitation in the Philips DICOMs, not dcm2niix.

[Slice timing correction](https://www.mccauslandcenter.sc.edu/crnl/tools/stc) can account for some variability in fMRI datasets. Unfortunately, Philips DICOM data [does not encode slice timing information](https://neurostars.org/t/heudiconv-no-extraction-of-slice-timing-data-based-on-philips-dicoms/2201/4). Therefore, dcm2niix is unable to populate the "SliceTiming" BIDS field. However, one can typically infer slice timing by recording the [mode and number of packages](https://en.wikibooks.org/w/index.php?title=SPM/Slice_Timing&stable=0#Philips_scanners) reported for the sequence on the scanner console.
[Slice timing correction](https://www.mccauslandcenter.sc.edu/crnl/tools/stc) can account for some variability in fMRI datasets. Unfortunately, Philips DICOM data [does not encode slice timing information](https://neurostars.org/t/heudiconv-no-extraction-of-slice-timing-data-based-on-philips-dicoms/2201/4). Therefore, dcm2niix is unable to populate the "SliceTiming" BIDS field. However, one can typically infer slice timing by recording the [mode and number of packages](https://en.wikibooks.org/w/index.php?title=SPM/Slice_Timing&stable=0#Philips_scanners) reported for the sequence on the scanner console or the [sequence PDF](http://adni.loni.usc.edu/wp-content/uploads/2017/09/ADNI-3-Basic-Philips-R5.pdf). For precise timing, it is also worth knowing if equidistant "temporal slice spacing" is set and whether "prospect. motion corr." is on or off (if on, a short delay occurs between volumes).

Likewise, the BIDS tag "PhaseEncodingDirection" allows tools like [eddy](https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/eddy) and [TOPUP](https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/topup) to undistort images. While the Philips DICOM header distinguishes the phase encoding axis (e.g. anterior-posterior vs left-right) it does not encode the polarity (A->P vs P->A).

Another value desirable for TOPUP is the "TotalReadoutTime". Again, one can not calculate this from Philips DICOMs. If you do decide to calculate this using values from the MRI console, be aware that the [FSL definition](https://github.com/rordenlab/dcm2niix/issues/130) is not intuitive for scans with interpolation, partial Fourier, parallel imaging, etc. However, it should be pointed out that the "TotalReadoutTime" only inlfuences TOPUP's calibrated validation images that are typically ignored. The data used in subsequent steps will not be influenced by this value.
Another value desirable for TOPUP is the "TotalReadoutTime". Again, one can not confidently calculate this from Philips DICOMs (though on can [appoximate it if you make a few assumptions](https://github.com/nipreps/sdcflows/issues/5)). If you do decide to calculate this using values from the MRI console, be aware that the [FSL definition](https://github.com/rordenlab/dcm2niix/issues/130) is not intuitive for scans with interpolation, partial Fourier, parallel imaging, etc. However, it should be pointed out that the "TotalReadoutTime" only influences TOPUP's calibrated validation images that are typically ignored. The data used in subsequent steps will not be influenced by this value.

## Partial Volumes

NIfTI expects all 3D volumes of a 4D series to have the same number of series (e.g. a time series of 3D fMRI volumes, or a diffusion set with 3D volumes with different gradients applied). If a fMRI sequence is aborted part way through, it is possible that a Philips scanner will only save part of the final volume. An example would be where the total slices (9970) does not equal Dynamics (290) x slices (35) = 10150. Current versions of dcm2niix expect complete volumes. You can repair your data using the console or a Python script, as discussed in [issue 357](https://github.com/rordenlab/dcm2niix/issues/357). To resolve this situation by hand you could also [rename](RENAMING.md) your DICOM files with a call like `./dcm2niix -r y -f %t/%s_%p_%4y_%2r.dcm ~/out 0020,0100`. In this example, the [`%4y`](FILENAMING.md) parameter adds the volume (Temporal Position, 0020,0100) to the filename, allowing you to identify volumes with missing slices.

## Non-Image DICOMs

Expand Down