From 3011cbd7fa09c78b04a250d79d594f89c4e056ab Mon Sep 17 00:00:00 2001 From: Gabe Fierro Date: Wed, 22 May 2024 09:04:21 -0600 Subject: [PATCH] update 223p.ttl --- _static/223p.ttl | 5216 ++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 5216 insertions(+) create mode 100644 _static/223p.ttl diff --git a/_static/223p.ttl b/_static/223p.ttl new file mode 100644 index 0000000..835116a --- /dev/null +++ b/_static/223p.ttl @@ -0,0 +1,5216 @@ + "219V Line-Neutral Voltage" . + . + . + . + . + . + . + "219V Line-Neutral Voltage" . + . + "415V Line-Line Voltage" . + . + . + . + . + . + . + "415V Line-Line Voltage" . + . + "Generator" . + . + _:dfa3b0e3830ddefcb491b2d7cdac9eb . + _:50a32f68d41052e79e5611550b9e622b . + . + . + "An energy transducer that transforms non-electric energy into electric energy." . + "Role-Heating" . + . + . + . + . + "Role-Heating" . + "Power over Ethernet" . + . + _:38ed484f44885055ee9dbb7ffc4d6ca3 . + _:3c12b196f6b59823f073353b14a59e8f . + _:a6ecfcced590ee0eb66e7ad265774eb1 . + . + . + . + "This class has enumerated subclasses of Power over Ethernet." . + _:948e19725528b0bd793d11d7a4ba249f . + _:46bc4ee0ca3c1ab71d0968925ced71eb . + "Concept" . + "true"^^ . + . + _:25ca38abc2f19df3627a7b7bd4a91f70 . + _:b26ba634b5147f7631e4c6bdc6b0c1a7 . + . + . + "All classes defined in the 223 standard are subclasses of s223:Concept." . + "Electromagnetic Wave" . + . + . + . + . + "This class has enumerated subclasses of electromagnetic energy at any frequency range." . + "Valve" . + . + . + . + "A device to regulate or stop the flow of fluid in a pipe or a duct by throttling." . + "EnumerationKind Numerical" . + . + . + _:71f6b6ed3e6d1d51c7a545330a0e4a24 . + _:51f4f236abf807e9798ec9292adfe522 . + _:76ddc1b8ad3394271f05d23b3e437f9 . + . + . + . + "Numerical enumeration kinds are used to support the definitions of the Electricity medium. The enumerations instances in these classes have names that are recognizable by humans but are just a string for a computer application. To avoid the need to parse strings, each of these enumeration kinds have properties associated with the enumeration that represent electrical phase, voltage, and frequency. The purpose of these properties is to enable a machine to query them and obtain the same information that a person would associate with the sting" . + . + "347V Voltage" . + . + . + . + . + . + . + "347V Voltage" . + . + "347"^^ . + "Domain-Fire" . + . + . + . + . + "The domain Fire represents equipment used to provide fire detection and protection within a building. Example equipment that might be fall within a Fire domain include smoke detectors, alarm annunciators, and emergency public address systems. " . + "3810V Voltage" . + . + . + . + . + . + . + "3810V Voltage" . + . + "3810"^^ . + "Object Name" . + . + "The Object_Name property of the object being referenced. For example, for the object name of an Analog Value Object, see ASHRAE 135-2020 Clause 12.4.2." . + "Electrical Phase Identifier C" . + . + . + . + . + "The value of the associated Property identifies the electrical phase C of the Connection." . + "DCNegativeVoltage-6.0V" . + . + . + . + . + . + . + "DCNegativeVoltage-6.0V" . + . + "EnumerationKind Aspect" . + . + . + . + . + "This class has enumerated subclasses usually used to specify the context of a s223:Property. The following table lists all of the defined enumerations for Aspect. \n Some Aspect enumerations have subclasses for more specific use. Those subclasses are not shown in the table but each of them are defined in `s223:Aspect-DayOfWeek` - `s223:Aspect-ElectricalVoltagePhases`. \n The following table lists all of the defined enumerations for Aspect." . + "240V Line-Neutral Voltage" . + . + . + . + . + . + . + "240V Line-Neutral Voltage" . + . + "Dimensionless Number of Electrical Phases" . + . + . + . + . + . + "This class has enumerated instances of number of electrical phases. The s223:hasNumberOfElectricalPhases relation points to one of the values of this enumeration." . + . + "Aspect-ServiceFactor" . + . + . + . + . + "The service factor of something characterized by a dimensionless value of this Property." . + "Aspect-Latent" . + . + . + . + . + "The latent value of something characterized by this Property." . + "Dimensioned Line-Line Voltage" . + . + . + . + _:99c3481fa82c191bc6e5050664fcd759 . + . + . + . + "This class has enumerated instances of common line-line voltages." . + . + "Light sensor" . + . + . + . + "A LightSensor is a specialization of a Sensor that observes a QuantifiableObservableProperty that represents a luminance measurement." . + "Electrical Phase Identifier B" . + . + . + . + . + "The value of the associated Property identifies the electrical phase B of the Connection." . + "Aspect-Deadband" . + . + . + . + . + "Aspect-Deadband" . + "DCNegativeVoltage-190.0V" . + . + . + . + . + . + . + "DCNegativeVoltage-190.0V" . + . + "Particulate-PM10.0" . + . + . + . + . + "Particulate-PM10.0" . + "AC-6600VLL-3810VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + "AC-6600VLL-3810VLN-1Ph-60Hz" . + . + "Numerical-DCVoltage" . + . + . + . + _:7d1869db5fb5be9eb41bb27f0f4d9d72 . + . + . + . + "This class has enumerated instances of common positive and negative voltages, plus zero volts." . + . + "Concentration sensor" . + . + . + . + "A ConcentrationSensor is a specialization of a Sensor that observes a QuantifiableObservableProperty that represents the concentration of a substance in a medium." . + "Binary True" . + . + . + . + . + "Binary True" . + "AC-208VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-208VLN-1Ph-60Hz" . + . + "EnumerationKind Phase" . + . + . + . + . + "This class has enumerated subclasses of thermodynamic phase, i.e. states of matter." . + "Heat Recovery" . + . + . + . + . + "Heat Recovery" . + "has connection point" . + . + "The relation hasConnectionPoint is part of a pair of relations that bind a Connectable thing to a ConnectionPoint. It is the inverse of the relation isConnectionPointOf (see `s223:isConnectionPointOf`)." . + . + "Inverter" . + . + _:ab0bca7c1c0522f3fb41282e88e3181e . + _:204d21e0961486f298b55ac6cbfb88c2 . + . + . + "An electric energy converter that changes direct electric current to alternating current." . + "Abstract sensor" . + "true"^^ . + . + _:1aa69977ba2e5234b9e5c13aa5b0af88 . + _:ad69e14c6ae82acb4ab45651fb608dac . + . + . + "This is an abstract class that represents properties that are common to all sensor types." . + "Medium-Refrigerant" . + . + . + . + . + "This class has enumerated subclasses of commonly used refrigerants." . + "Coil" . + . + _:6be1b3d13402ef027b2dfae12a00d4fb . + _:1d630b704aa49026df640a762ff01dc1 . + . + . + "A cooling or heating element made of pipe or tube that may or may not be finned and formed into helical or serpentine shape." . + "Occupant motion sensor" . + . + . + . + "A subclass of OccupancySensor that observes motion within its sensing region." . + "Water-Chilled water" . + . + . + . + . + "Water-Chilled water" . + "Cooling" . + . + . + . + . + "Cooling" . + "Property Identifier" . + . + "The Object_Identifier property of the object being referenced. For example, for the object identifier of an Analog Value Object, see ASHRAE 135-2020 Clause 12.4.1." . + "AC-347VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-347VLN-1Ph-60Hz" . + . + "AC-240VLL-139VLN-1Ph-50Hz" . + . + . + . + . + . + . + . + "AC-240VLL-139VLN-1Ph-50Hz" . + . + "139V Voltage" . + . + . + . + . + . + . + "139V Voltage" . + . + "139"^^ . + "AC-120VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-120VLN-1Ph-60Hz" . + . + "Furnace" . + . + _:ae80952ade8b41cc229621215a735c59 . + _:eac701aaba858ad151222aa73c3045ae . + . + . + "An enclosed chamber or structure in which heat is produced, as by burning fuel or by converting electrical energy. " . + "Device Name" . + . + "The name of the BACnet device being referenced, more formally the Object_Name property of the device object within the BACnet device. See ASHRAE 135-2020 Clause 12.11.2." . + "Electricity Signal" . + . + . + . + . + "This class has enumerated subclasses of common communication protocols." . + "Occupant counter" . + . + . + . + "A subclass of OccupancySensor that counts the population within its sensing region." . + "48V-Neg" . + . + . + . + . + . + . + "48V-Neg" . + "Fan coil unit" . + . + _:23c75ab36b68de61b07a7dca7661253d . + _:49ac683ec5d8215ef862106ef137e1fe . + _:bc17bec80be7a538d214f5b526ed068 . + _:2baf90bd33f4cff2ad7eedef7c709feb . + _:dba040fbb1018caba907c2cc8bb65865 . + . + . + "A device consisting of a heat exchanger (coil) and a fan to regulate the temperature of one or more spaces." . + "Aspect-StartupValue" . + . + . + . + . + "The startup value of something characterized by this Property." . + "DCNegativeVoltage-5.0V" . + . + . + . + . + . + . + "DCNegativeVoltage-5.0V" . + . + "Aspect-Manufacturer" . + . + . + . + . + "The value of the associated Property identifies the manufacturer." . + "380V-Pos" . + . + . + . + . + . + . + "380V-Pos" . + "AC-600VLL-1Ph-60Hz" . + . + . + . + . + . + . + "AC-600VLL-1Ph-60Hz" . + . + "3V-Neg-3V-Pos" . + . + . + . + . + . + . + "3V-Neg-3V-Pos" . + "Domain-Electrical" . + . + . + . + . + "The domain Electrical represents equipment used to provide electrical power within a building. Example equipment that might fall within an Electrical domain include breaker panels, switchgear, photovoltaic panels, and generators. " . + "Electrical Phase Identifier ABC" . + . + . + . + . + "The value of the associated Property identifies the electrical phase ABC of the Connection." . + "Temp sensor" . + . + . + . + "A TemperatureSensor is a specialization of a Sensor that observes a QuantifiableObservableProperty that represents a temperature measurement." . + "208V Line-Neutral Voltage" . + . + . + . + . + . + . + "208V Line-Neutral Voltage" . + . + "has Property" . + . + "The relation hasProperty associates any 223 Concept with a Property." . + "Aspect-CatalogNumber" . + . + . + . + . + "The value of the associated Property identifies the catalog number." . + "connects to" . + . + "The relation connectsTo binds a Connection to a Connectable thing to a Connection with an implied directionality. A connectsTo B indicates a flow from A to B." . + "EM-Light" . + . + . + . + . + "The EM-Light class has enumerated subclasses of what are considered visible or near-visible light." . + "AC-415VLL-240VLN-1Ph-50Hz" . + . + . + . + . + . + . + . + "AC-415VLL-240VLN-1Ph-50Hz" . + . + "Sensor" . + . + . + . + "A Sensor observes an ObservableProperty (see `s223:ObservableProperty`) which may be quantifiable (see `s223:QuantifiableObservableProperty`), such as a temperature, flowrate, or concentration, or Enumerable (see `s223:EnumeratedObservableProperty`), such as an alarm state or occupancy state." . + _:a463dbde6f441f265243bc4ce7ba8ca3 . + _:9f6a31ce14ef231026f0744757616eeb . + _:b23fc45068a73f424d43a686acebc . + _:cf813a89a634ce5b6f7e3141ea94fa9 . + "Created with TopBraid Composer" . + "AC-380VLL-219VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + "AC-380VLL-219VLN-1Ph-60Hz" . + . + "Function" . + . + _:956abe7694c40cbadf3866ccc6008ec4 . + _:78f3339dd3b49b6b4e52799e2486224 . + . + . + "A Function is used to model transfer and/or transformation of information (i.e. Property). It has relations to input Properties and output Properties. The actual algorithms that perform the transformations are described in CDL and are out of scope of the 223 standard." . + "ConnectionPoint" . + "true"^^ . + . + _:8499b286735736c879329fc2b181e2f3 . + _:d6e17fbe7f08173e50b901aeefe80ecd . + _:24eeba9675ec2715e70a5acc9e82f618 . + _:facbc2485a830f5d88e6cb077183c381 . + _:6401c5f8f09e0cfe2dbcecfbdec2e88d . + _:b47b63dfccb019eb813769a282cc6b46 . + _:978377bbe56b757b9b5b376bab5fd5d2 . + _:9fcfe8651b217d03632c0a71d5dc83d0 . + _:eb672900d92f5273b1f24407c88124a4 . + . + . + "\nA ConnectionPoint is an abstract modeling construct used to represent the fact that one connectable thing can be connected to another connectable thing using a Connection. It is the abstract representation of the flange, wire terminal, or other physical feature where a connection is made. Equipment, DomainSpaces and Junctions can have one or more ConnectionPoints (see `s223:Connectable`).\n\nA ConnectionPoint is constrained to relate to a specific medium such as air, water, or electricity which determines what other things can be connected to it. For example, constraining a ConnectionPoint to be for air means it cannot be used for an electrical connection.\n\nA ConnectionPoint belongs to exactly one connectable thing (see `s222:Connectable').\n\nConnectionPoints are represented graphically in this standard by a triangle with the point indicating a direction of flow, or a diamond in the case of a bidirectional flow as shown in Figure 6-1. \n\n![Graphical Representation of a ConnectionPoint.](figures/Figure_5-2_Graphical_Depiciton_of_Connection_Points.svg)\n\n " . + "Property Array Index" . + . + "If the property identified is of datatype array, this optional property of type Unsigned shall indicate the array index of\nthe element of the property referenced by the ReadProperty service or the Read Access Specification of the ReadPropertyMultiple service. If the bacnet:property-array-index is omitted, this shall mean that the entire\narray shall be referenced. See ASHRAE 135-2020 Clause 15.5.1.1.3 and Clause 15.7.1.1.1." . + "220V Voltage" . + . + . + . + . + . + . + "220V Voltage" . + . + "220"^^ . + "AC-400VLL-1Ph-50Hz" . + . + . + . + . + . + . + "AC-400VLL-1Ph-50Hz" . + . + "Connectable" . + "true"^^ . + . + _:18fe7900b9011f367e3422222a76891a . + _:c184ba3ff668a0f15d9c378c95b1d33 . + _:3a75deb0bfd118eb82b540d901e24b06 . + _:315b9c3fd5f37c7ea685b8dd832e4191 . + _:25b1700cb5fc47e1006c1aba3c714d11 . + _:765da9cb0adf91cf37fddd0af4dbe240 . + . + . + "Connectable is an abstract class representing a thing such as, Equipment (see `s223:Equipment`), DomainSpace (see `s223:DomainSpace`), or Junction (see `s223:Junction`) that can be connected via ConnectionPoints and Connections." . + "AC-4160VLL-3Ph-60Hz" . + . + . + . + . + . + . + "AC-4160VLL-3Ph-60Hz" . + . + "Speed" . + . + . + . + . + "This class has enumerated subclasses of speed settings of High, Medium, Low (plus Off)." . + "Aspect-Setpoint" . + . + . + . + . + "Aspect-Setpoint" . + "Aspect-StandardConditions" . + . + . + . + . + "Indicates the Property applies under standard conditions (such as standard temperature and pressure)." . + "Junction" . + . + _:5ac071980192450900deac330ce933e9 . + . + . + "A Junction is a modeling construct used when a branching point within a Connection (see `s223:Connection`) is of significance, such as specifying the observation location of a Sensor. When a Junction is used, what might have been modeled as a single, branched Connection is separated into three or more separate Connections, all tied together with the Junction and its associated ConnectionPoints." . + "60 Hertz" . + . + . + . + . + . + "60 Hertz" . + . + "60"^^ . + "Single Duct Terminal." . + . + _:221ae96653a94bccfd47900e94ff542f . + . + . + "An air-terminal unit assembly having one ducted air inlet and a damper for regulating the airflow rate." . + "Medium-Water" . + . + . + . + . + "This class has enumerated subclasses of water and aqueous solutions in various states." . + "5V" . + . + . + . + . + . + . + "This class has enumerated instances of all polarities of 5 volt electricity." . + "Tuesday" . + . + . + . + . + "Tuesday" . + "AC-240VLL-3Ph-50Hz" . + . + . + . + . + . + . + "AC-240VLL-3Ph-50Hz" . + . + "AC-240VLL-208VLN-120VLN-3Ph-60Hz" . + . + . + . + . + . + . + . + . + "AC-240VLL-208VLN-120VLN-3Ph-60Hz" . + . + "Role-Secondary" . + . + . + . + . + "Role-Secondary" . + "Role-Relief" . + . + . + . + . + "Role-Relief" . + "abstract" . + . + "If the relation abstract has a value of true, the associated class cannot be instantiated. " . + . + "connected through" . + . + "The relation connectedThrough associates a Connectable with a Connection." . + "Low" . + . + . + . + . + "Low" . + "DCVoltage-DCZero voltage" . + . + . + . + . + . + . + "DCVoltage-DCZero voltage" . + . + "Refrigerant-R-22" . + . + . + . + . + "Refrigerant-R-22" . + "observes" . + . + "The relation observes binds a sensor to one ObservableProperty `see s223:ObservableProperty` which is used by the sensor to generate a measurement value (ex. a temperature) or a simple observation of a stimulus causing a reaction (a current binary switch that closes a dry contact when a fan is powered on)." . + "Domain-Plumbing" . + . + . + . + . + "The domain Plumbing represents equipment used to provide domestic water within or outside a building. Example equipment that might fall within a Plumbing domain includes water meters, domestic hot water tanks, and sinks." . + "actuates" . + . + "The relation actuates binds an Actuator to the Equipment that it actuates. The Equipment will have the ActuatableProperty that commands the Actuator (see `s223:actuatedByProperty`)." . + "2V Voltage" . + . + . + . + . + . + . + "2V Voltage" . + . + "2"^^ . + "Substance-CO2" . + . + . + . + . + "Substance-CO2" . + "AC-3300VLL-1900VLN-3Ph-60Hz" . + . + . + . + . + . + . + . + "AC-3300VLL-1900VLN-3Ph-60Hz" . + . + "DCPositiveVoltage-3.0V" . + . + . + . + . + . + . + "DCPositiveVoltage-3.0V" . + . + "AC-240VLL-120VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + "AC-240VLL-120VLN-1Ph-60Hz" . + . + "Modulated 0-10V" . + . + . + . + . + "Modulated 0-10V" . + "Aspect-Electrical phase identifier" . + . + . + . + . + "The value of the associated Property identifies the electrical phase of the Connection." . + "Friday" . + . + . + . + . + "Friday" . + "AC-3300VLL-1900VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + "AC-3300VLL-1900VLN-1Ph-60Hz" . + . + "Heating coil" . + . + _:d52d5ebf82e9586318e7c244d31e5c01 . + . + . + "A coil that provides heating." . + "Light-Infrared" . + . + . + . + . + "Light-Infrared" . + "Aspect-Threshold" . + . + . + . + . + "The threshold value of something characterized by this Property." . + "AC-208VLL-1Ph-60Hz" . + . + . + . + . + . + . + "AC-208VLL-1Ph-60Hz" . + . + "231V Voltage" . + . + . + . + . + . + . + "231V Voltage" . + . + "231"^^ . + "has input" . + . + "The relation hasInput is used to relate a Function (see `s223:Function`) to a Property (see `s223:Property`) that is used as input." . + "48V" . + . + . + . + . + . + . + "This class has enumerated instances of all polarities of 48 volt electricity." . + "Particulate-PM1.0" . + . + . + . + . + "Particulate-PM1.0" . + "Motion-True" . + . + . + . + . + "Motion-True" . + "Aspect-Loss" . + . + . + . + . + "The magnitude of loss of something characterized by this Property." . + "Unoccupied" . + . + . + . + . + "Unoccupied" . + "Illuminance sensor" . + . + . + . + "A subclass of LightSensor that observes the level of illuminance." . + "Electricity-Earth" . + . + . + . + . + "Electricity-Earth" . + "Role-Condenser" . + . + . + . + . + "Role-Condenser" . + "AC-208VLL-120VLN-3Ph-60Hz" . + . + . + . + . + . + . + . + "AC-208VLL-120VLN-3Ph-60Hz" . + . + "BACnetExternalReference" . + . + . + . + "BACnetExternalReference is a subclass of ExternalReference that contains BACnet protocol parameter values necessary to associate a property with a value." . + "AC-139VLN-1Ph-50Hz" . + . + . + . + . + . + . + "AC-139VLN-1Ph-50Hz" . + . + "Three Phase AC Electricity" . + . + . + . + . + . + "Three Phase AC Electricity" . + . + "3"^^ . + "127V Voltage" . + . + . + . + . + . + . + "127V Voltage" . + . + "127"^^ . + "Run status" . + . + . + . + . + "This class is a more general form of EnumerationKind-OnOff, allowing for additional status values beyond on or off." . + "DCPositiveVoltage-380.0V" . + . + . + . + . + . + . + "DCPositiveVoltage-380.0V" . + . + "Electric outlet" . + . + _:cc5482412827252a4345ebdd4691ecac . + _:eb8ccad4fd958c6f4dd86b719d014b4a . + . + . + "A device to which a piece of electrical equipment can be connected in order to provide it with electricity" . + "Direction-Bidirectional" . + . + . + . + . + "One of the set of enumeration values for the hasDirection property used to characterize the direction of flow associated with an instance of a ConnectionPoint. The value Bidirectional indicates that the flow direction is not fixed in one direction. It depends on the status of some other part of the system, such as a valve position, that is expected to change during operation." . + "Electrical Phase Identifier CA" . + . + . + . + . + "The value of the associated Property identifies the electrical phase CA of the Connection." . + "AC-240VLL-3Ph-60Hz" . + . + . + . + . + . + . + "AC-240VLL-3Ph-60Hz" . + . + "Aspect-Delta" . + . + . + . + . + "Used to signify the associated Property has a delta (difference) value." . + "AC-6600VLL-3810VLN-3Ph-60Hz" . + . + . + . + . + . + . + . + "AC-6600VLL-3810VLN-3Ph-60Hz" . + . + "DCPositiveVoltage-190.0V" . + . + . + . + . + . + . + "DCPositiveVoltage-190.0V" . + . + "Medium" . + . + . + . + . + "Medium" . + "connected to" . + . + "The relation connectedTo indicates that connectable things are connected with a specific flow direction. A is connectedTo B, means a directionality beginning at A and ending at B. The inverse direction is indicated by connectedFrom (see `s223:connectedFrom`)." . + . + . + "Unknown" . + . + . + . + . + "Unknown" . + "6000V Line-Line Voltage" . + . + . + . + . + . + . + "6000V Line-Line Voltage" . + . + "connects at" . + . + "The connectsAt relation binds a Connection to a specific ConnectionPoint. See Figure x.y." . + . + "Created with TopBraid Composer" . + "Role-Load" . + . + . + . + . + "Role-Load" . + "Priority for Writing" . + . + "This parameter shall be an integer in the range 1..16, which indicates the priority assigned to the WriteProperty service. If an attempt\nis made to write to a commandable property without specifying the bacnet:priority-for-writing, a default priority of 16 (the lowest priority) shall\nbe assumed. If an attempt is made to write to a property that is not commandable with a specified priority, the priority shall be\nignored. See ASHRAE 135-2020 Clause 15.9.1.1.5." . + "has external reference" . + . + "The relation hasExternalReference is used to relate a Property to an external telemetry source." . + "Aspect-Year" . + . + . + . + . + "The value of the associated Property identifies the year of manufacture." . + "Flow sensor" . + . + . + . + "A FlowSensor is a specialization of a Sensor that produces an ObservableProperty that is quantifiable and represents a flow measurement." . + "Aspect-Total" . + . + . + . + . + "The total amount of something characterized by this Property." . + "DCNegativeVoltage-24.0V" . + . + . + . + . + . + . + "DCNegativeVoltage-24.0V" . + . + "AC-190VLL-1Ph-50Hz" . + . + . + . + . + . + . + "AC-190VLL-1Ph-50Hz" . + . + "AC-240VLL-1Ph-60Hz" . + . + . + . + . + . + . + "AC-240VLL-1Ph-60Hz" . + . + "5770V Line-Neutral Voltage" . + . + . + . + . + . + . + "5770V Line-Neutral Voltage" . + . + "120V Voltage" . + . + . + . + . + . + . + "120V Voltage" . + . + "120"^^ . + "Unknown" . + . + . + . + . + "Unknown" . + "Light-Visible" . + . + . + . + . + "Light-Visible" . + "Occupant presence sensor" . + . + . + . + "A subclass of OccupancySensor that observes presence within its sensing region." . + "has Medium" . + . + "The relation hasMedium is used to indicate what medium is flowing through the connection (e.g., air, water, electricity). The possible values are defined in EnumerationKind-Medium (see `s223:EnumerationKind-Medium`)." . + "Open" . + . + . + . + . + "Open" . + "Enumeration kind" . + . + _:7b59e4fbc1fa4bd2030bd4cef5c08b92 . + . + . + . + "This is the encapsulating class for all EnumerationKinds. \n EnumerationKinds define the (closed) set of permissible values for a given purpose. \n For example, the DayOfWeek EnumerationKind enumerates the days of the week and allows no other values.\n \nEnumerationKinds are arranged in a tree hierarchy, with the root class named EnumerationKind. Each subclass is named starting with its immediate superclass, followed by a hyphen and a name that is unique among the sibling superclasses. \nCertain validation constraints exist in the standard that evaluate compatibility of EnumerationKinds. \nTwo values are deemed compatible if they are the same or if one is a direct ancestor (or descendant) of the other." . + "Electrical Phase Identifier A" . + . + . + . + . + "The value of the associated Property identifies the electrical phase A of the Connection." . + "Direction" . + . + . + . + . + "This class has enumerated subclasses of Bidirectional, Inlet and Outlet used to qualify ConnectionPoints." . + "Electric meter" . + . + . + . + "A device that measures the properties of electric energy." . + "Dimensioned Line-Neutral Voltage" . + . + . + . + _:890122351aab8f5bdf001683d63658a3 . + . + . + . + "This class has enumerated instances of common line-neutral voltages." . + . + "240V Line-Line Voltage" . + . + . + . + . + . + . + "240V Line-Line Voltage" . + . + "6V-Pos" . + . + . + . + . + . + . + "6V-Pos" . + "Electrical resistance heater" . + . + _:d4c16a91f90b66540807bc03acbf1ec6 . + _:bf101fdfdde1fbe9e6354db90d59a95f . + . + . + "Resistance heaters provide electrical resistance heating, for example an electric heating coil within a Fan Coil Unit." . + "Off" . + . + . + . + . + "Off" . + "AC-6000VLL-3460VLN-3Ph-60Hz" . + . + . + . + . + . + . + . + "AC-6000VLL-3460VLN-3Ph-60Hz" . + . + "AC-380VLL-3Ph-60Hz" . + . + . + . + . + . + . + "AC-380VLL-3Ph-60Hz" . + . + "Closed" . + . + . + . + . + "Closed" . + "Role" . + . + . + . + . + "This class has enumerated subclasses of roles played by entities, such as cooling, generator, relief, return." . + "Role-Controller" . + . + . + . + . + "Role-Controller" . + "Aspect-Efficiency" . + . + . + . + . + "The efficiency of something characterized by a dimensionless value of this Property." . + "Pump" . + . + _:fee9f9bc11856aa4548096c0dd4fa271 . + _:64a1d56976bd07bb0dcc1826a61d508d . + . + . + "A machine for imparting energy to a fluid, drawing a fluid into itself through an entrance port, and forcing the fluid out through an exhaust port." . + "AC-3300VLL-1Ph-60Hz" . + . + . + . + . + . + . + "AC-3300VLL-1Ph-60Hz" . + . + "has aspect" . + . + "hasAspect is used to establish the context of a Property. The value must be an instance of EnumerationKind. For example, if a Property has a Temperature value of 45.3, the hasAspect relation is used to state what that represents, such as a Temperature limit during working hours, etc. A Property can have any number of hasAspect relations, as needed to establish the context." . + "Domain-PhysicalSecurity" . + . + . + . + . + "The domain Security represents equipment that provides physical access control within or outside a building. Example equipment that might fall within a PhysicalSecurity domain include cameras, keycard sensors, and biometric scanners." . + "Unknown" . + . + . + . + . + "Unknown" . + "Medium-Oil" . + . + . + . + . + "This class has enumerated subclasses of oil." . + "AC-480VLL-277VLN-3Ph-60Hz" . + . + . + . + . + . + . + . + "AC-480VLL-277VLN-3Ph-60Hz" . + . + "380V-Neg" . + . + . + . + . + . + . + "380V-Neg" . + "has frequency" . + . + "The relation hasFrequency is used to identify the frequency of an AC electricity enumeration kind. " . + "6600V Line-Line Voltage" . + . + . + . + . + . + . + "6600V Line-Line Voltage" . + . + "1730V Voltage" . + . + . + . + . + . + . + "1730V Voltage" . + . + "1730"^^ . + "DCNegativeVoltage-380.0V" . + . + . + . + . + . + . + "DCNegativeVoltage-380.0V" . + . + "Actuator" . + . + _:57d2eaa39462db87a80b58f10b5d5653 . + _:687223cd00d53160697fd0dc639dab72 . + . + . + "A piece of equipment, either electrically, pneumatically, or hydraulically operated, that makes a change in the physical world, such as the position of a valve or damper." . + "Aspect-SerialNumber" . + . + . + . + . + "The value of the associated Property identifies the serial number." . + "480V Voltage" . + . + . + . + . + . + . + "480V Voltage" . + . + "480"^^ . + "has setpoint" . + . + "This relation binds a control setpoint to the quantifiable property indicating the desired value which the control process is trying to maintain." . + "24V-Neg-24V-Pos" . + . + . + . + . + . + . + "24V-Neg-24V-Pos" . + "415V Voltage" . + . + . + . + . + . + . + "415V Voltage" . + . + "415"^^ . + "Battery" . + . + . + . + "A container consisting of one or more cells, in which chemical energy is converted into electricity and used as a source of power." . + "Terminal Unit" . + . + _:c66e2c13a5c4f119d9efd20a8ac67bbe . + _:9614d22eb75aefc47f9df60333e0569c . + . + . + "An air terminal that modulates the volume of air delivered to a space." . + "Three way valve" . + . + _:ad669fa2e1a8422424d3c754efcd0e9f . + . + . + "A Valve that can divert a fluid in one of three directions." . + "Domain Space" . + . + _:5bcb35f83726ddaedfa64c093d443cde . + . + . + "A DomainSpace is a member (or component) of a Zone and is associated with a Domain such as Lighting, HVAC, PhysicalSecurity, etc. Physical spaces enclose Domain spaces." . + "Radiator" . + . + _:282431aa52007b83d1b2bfc5c4965982 . + . + . + "A radiator provides heating to a room using electricity, steam or water (e.g., electric baseboard heaters)." . + "Motion-False" . + . + . + . + . + "Motion-False" . + "240V Voltage" . + . + . + . + . + . + . + "240V Voltage" . + . + "240"^^ . + "Door" . + . + _:69b0fb1cad311ddd74866bb096e7b56d . + . + . + "A hinged, sliding, or revolving barrier at the entrance to a building or room." . + "Ethernet switch" . + . + _:db9653614ef3f0ea08f5e95cf9864534 . + _:c28effc05f4c161db34d4d2fb6f44967 . + . + . + "A type of network hardware that connects cabled devices, such as computers and Wi-Fi access points, in an Ethernet LAN so they can communicate with each other and to the internet." . + "Electricity DC" . + . + . + _:323b635d5d3193a8bc4a95abbff38b3f . + . + . + . + "This class has enumerated instances of all DC forms of electricity." . + "Binary Unknown" . + . + . + . + . + "Binary Unknown" . + "190V-Neg-190V-Pos" . + . + . + . + . + . + . + "190V-Neg-190V-Pos" . + "Day of week-Weekday" . + "Weekday" . + . + . + . + . + "This class defines the EnumerationKind values of Monday, Tuesday, Wednesday, Thursday, and Friday" . + "Created with TopBraid Composer" . + "4160V Voltage" . + . + . + . + . + . + . + "4160V Voltage" . + . + "4160"^^ . + "has measurement resolution" . + . + "The hasMeasurementResolution relation is used to link to a numerical property whose value indicates the smallest recognizable change in engineering units that the sensor can indicate. " . + "executes" . + . + "The relation executes is used to specify that a Controller (see `s223:Controller`) is responsible for the execution of a Function (see `s223:Function`). " . + "Medium-NaturalGas" . + . + . + . + . + "This class has enumerated subclasses of natural gas in various states." . + "AC-240VLL-139VLN-3Ph-50Hz" . + . + . + . + . + . + . + . + "AC-240VLL-139VLN-3Ph-50Hz" . + . + "231V Line-Neutral Voltage" . + . + . + . + . + . + . + "231V Line-Neutral Voltage" . + . + "hasVoltage" . + . + "The relation hasVoltage is used to identify the voltage of an electricity enumeration kind. " . + "3V Voltage" . + . + . + . + . + . + . + "3V Voltage" . + . + "3"^^ . + "A reference to the unit of measure of a QuantifiableProperty of interest." . + "Aspect-Nominal" . + . + . + . + . + "The nominal level of something characterized by this Property." . + "On" . + . + . + . + . + "On" . + "380V Line-Line Voltage" . + . + . + . + . + . + . + "380V Line-Line Voltage" . + . + "Enumerable Property" . + . + _:98751a5d4737bda38d40f8c1d5a5edd3 . + . + . + "An EnumerableProperty is a property with an enumerated (fixed) set of possible values." . + "Aspect-Maximum" . + . + . + . + . + "The maximum allowable level of something characterized by this Property." . + "5V-Pos" . + . + . + . + . + . + . + "5V-Pos" . + "Cooling coil" . + . + _:6fa6788f50eb19c2b148183a50796025 . + . + . + "A coil that provides cooling." . + "Signal IEC14908" . + . + . + . + . + "Signal IEC14908" . + "AC-10000VLL-5770VLN-3Ph-60Hz" . + . + . + . + . + . + . + . + "AC-10000VLL-5770VLN-3Ph-60Hz" . + . + "Correlated color temperature sensor" . + . + . + . + "A subclass of LightSensor that observes the color of light." . + "mapsTo" . + . + "The relation mapsTo is used to associate a ConnectionPoint of a Connectable to a corresponding ConnectionPoint of the one containing it (see `pub:equipment-containment`). The associated ConnectionPoints must have the same direction (see `s223:EnumerationKind-Direction`) and compatiable medium Substance-Medium." . + "Filter" . + . + _:fa8db41929dc52d5ef03d91ecf8c705b . + _:28bdf94752599f1f309d8c490974181 . + . + . + "A device that removes contaminants from gases or liquids." . + "Binary False" . + . + . + . + . + "Binary False" . + "AC-240VLL-208VLN-120VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + . + "AC-240VLL-208VLN-120VLN-1Ph-60Hz" . + . + "Aspect-Sensible" . + . + . + . + . + "The sensible value of something characterized by this Property." . + "AC-10000VLL-3Ph-60Hz" . + . + . + . + . + . + . + "AC-10000VLL-3Ph-60Hz" . + . + "AC-380VLL-1Ph-60Hz" . + . + . + . + . + . + . + "AC-380VLL-1Ph-60Hz" . + . + "HVAC operating mode" . + . + . + . + . + "HVACOperatingMode has enumerated subclasses of the policy under which the HVAC system or equipment is operating." . + "has observation location high" . + . + "The relation hasObservationLocationHigh associates a differential sensor to one of the topological locations where a differential property is observed (see `s223:observes`)." . + . + "AC-127VLN-1Ph-50Hz" . + . + . + . + . + . + . + "AC-127VLN-1Ph-50Hz" . + . + "Aspect-Phase angle" . + . + . + . + . + "Aspect-Phase angle" . + "Particulate" . + . + . + . + . + "This class has enumerated subclasses of particulates in various size ranges." . + "AC-190VLL-110VLN-3Ph-50Hz" . + . + . + . + . + . + . + . + "AC-190VLL-110VLN-3Ph-50Hz" . + . + "6V" . + . + . + . + . + . + . + "This class has enumerated instances of all polarities of 6 volt electricity." . + "AC-220VLL-127VLN-1Ph-50Hz" . + . + . + . + . + . + . + . + "AC-220VLL-127VLN-1Ph-50Hz" . + . + "Dimensioned Voltage" . + . + . + _:9799518702dcf5dbfeaf60f434848a42 . + _:cdec220def885a96fb042136f7138694 . + . + . + . + "This class has enumerated instances of common voltages." . + . + "Dimensioned Frequency" . + . + . + _:bb9d76456086a4a0ca491564a237b887 . + _:49d08b7aba86edbcbcc6576d723500f7 . + . + . + . + "This class has enumerated instances of common electrical frequencies." . + . + "48V Voltage" . + . + . + . + . + . + . + "48V Voltage" . + . + "48"^^ . + "DCPositiveVoltage-12.0V" . + . + . + . + . + . + . + "DCPositiveVoltage-12.0V" . + . + "comment" . + . + "Description of constraints for s223." . + . + "AC-208VLL-3Ph-60Hz" . + . + . + . + . + . + . + "AC-208VLL-3Ph-60Hz" . + . + "50 Hertz" . + . + . + . + . + . + "50 Hertz" . + . + "50"^^ . + "encloses" . + . + "The relation encloses is used to indicate that a domain space (see: `s223:DomainSpace`) can be found inside a physical space (see `s223:PhysicalSpace`). " . + "AC-240VLN-1Ph-50Hz" . + . + . + . + . + . + . + "AC-240VLN-1Ph-50Hz" . + . + "12V-Neg" . + . + . + . + . + . + . + "12V-Neg" . + "AC-4160VLL-2400VLN-3Ph-60Hz" . + . + . + . + . + . + . + . + "AC-4160VLL-2400VLN-3Ph-60Hz" . + . + "139V Line-Neutral Voltage" . + . + . + . + . + . + . + "139V Line-Neutral Voltage" . + . + "220V Line-Line Voltage" . + . + . + . + . + . + . + "220V Line-Line Voltage" . + . + "Window" . + . + _:8d4cbd571611ce5fc68f858fd8625329 . + _:3250e3df89b16ee3056dd73a8b3b22fc . + . + . + "A daylight opening on a vertical or nearly vertical area of a room envelope." . + "connects through" . + . + "The relation connectedThrough binds a Connectable thing to a Connection without regard to the direction of flow. It is used to discover what connection links two connectable things." . + . + "Two way valve" . + . + _:a55b6296a3d5a6a5fab831b5267fc513 . + _:888a9ee0ada7fbffddddda0e9ac8db91 . + . + . + "A Valve that can divert a fluid in one of two directions." . + "380V Voltage" . + . + . + . + . + . + . + "380V Voltage" . + . + "380"^^ . + "Aspect-Nominal Frequency" . + . + . + . + . + "The value of the associated Property identifies the nominal frequency of the medium" . + "A Thermal Energy Storage System" . + . + _:43d9eecac85a3bedb97d80571d96fd4a . + . + . + "A device that stores thermal energy." . + "Aspect-High limit" . + . + . + . + . + "Aspect-High limit" . + "ExternalReference" . + "true"^^ . + . + . + . + "ExternalReference is an abstract class that represents a thing that contains API or protocol parameter values necessary to associate a property with a value." . + "Aspect-Rated" . + . + . + . + . + "The rated value of something characterized by this Property." . + "AC-190VLL-110VLN-1Ph-50Hz" . + . + . + . + . + . + . + . + "AC-190VLL-110VLN-1Ph-50Hz" . + . + "Boiler" . + . + _:1ee8ef6dd5c14e8b99794a1cb46a9572 . + _:27102dcaae5d96598105e82b70815b46 . + . + . + "A closed, pressure vessel that uses fuel or electricity for heating water or other fluids to supply steam or hot water for heating, humidification, or other applications." . + "480V Line-Line Voltage" . + . + . + . + . + . + . + "480V Line-Line Voltage" . + . + "Day of Week" . + . + . + . + . + "This class has enumerated subclasses of Monday, Tuesday, Wednesday, Thursday, Friday, Saturday and Sunday. The Weekend and Weekday EnumerationKinds define subsets of this EnumerationKind for Mon-Fri and Sat,Sun, respectively" . + "Humidistat" . + . + . + . + "An automatic control device used to maintain humidity at a fixed or adjustable setpoint." . + "4160V Line-Line Voltage" . + . + . + . + . + . + . + "4160V Line-Line Voltage" . + . + "Medium-Glycol" . + . + . + . + . + "Medium-Glycol" . + "AC-3460VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-3460VLN-1Ph-60Hz" . + . + "has domain" . + . + "The relation hasDomain is used to indicate what domain a Zone or DomainSpace pertains to (e.g. HVAC, lighting, electrical, etc.). Possible values are defined in EnumerationKind-Domain (see `s223:EnumerationKind-Domain`)." . + "Role-Generator" . + . + . + . + . + "Role-Generator" . + "10000V Voltage" . + . + . + . + . + . + . + "10000V Voltage" . + . + "10000"^^ . + "Ventilating" . + . + . + . + . + "Ventilating" . + "Gas-Super heated" . + . + . + . + . + "Gas-Super heated" . + "is connection point of" . + . + "The relation isConnectionPointOf is part of a pair of relations that bind a ConnectionPoint to a Connectable thing. It is the inverse of the relation hasConnectionPoint (see `s223:hasConnectionPoint`)." . + . + "of medium" . + . + "The relation ofMedium is used to associate a Property with a specific Medium." . + "object-identifier" . + . + "The Object_Identifier property of the object being referenced. For example, for the object identifier of an Analog Value Object, see ASHRAE 135-2020 Clause 12.4.1." . + "Fume hood" . + . + _:1c64d4406c3b1bf3c4c1f41c4117e571 . + _:4657d03dd1f55d64cffd056a1c018225 . + . + . + "A fume-collection device mounted over a work space, table, or shelf and serving to conduct unwanted gases away from an area." . + "Bidirectional Connection Point" . + . + . + . + "A BidirectionalConnectionPoint is a predefined subclass of ConnectionPoint. Using a BidirectionalConnectionPoint implies that the flow direction is not fixed in one direction. It depends on the status of some other part of the system, such as a valve position, that is expected to change during operation (see `s223:Direction-Bidirectional`) or to model energy transfer occurring without specific flow direction." . + "0V Voltage" . + . + . + . + . + . + . + "0V Voltage" . + . + "0"^^ . + "AC-220VLL-127VLN-3Ph-50Hz" . + . + . + . + . + . + . + . + "AC-220VLL-127VLN-3Ph-50Hz" . + . + "24V" . + . + . + . + . + . + . + "This class has enumerated instances of all polarities of 24 volt electricity." . + "AC-600VLL-347VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + "AC-600VLL-347VLN-1Ph-60Hz" . + . + "VariableFrequencyDrive" . + . + _:d83615ca483e69a5cedb2cafbead31b2 . + _:282dbe68c0360b160ddf4e36b93795d4 . + _:cc2b0acccb3b90185b994a5e1a6457d8 . + . + . + "An electronic device that varies its output frequency to vary the rotating speed of a motor, given a fixed input frequency. Used with fans or pumps to vary the flow in the system as a function of a maintained pressure." . + "has output" . + . + "The relation hasOutput is used to relate a Function (see `s223:Function`) to a Property (see `s223:Property`) that is calculated by the Function." . + "Role-Evaporator" . + . + . + . + . + "Role-Evaporator" . + "ElectricalVoltagePhases-BNLineNeutralVoltage" . + . + . + . + . + "Identifies the Line-to-neutral voltage is between phases B and N" . + "Enumerated actuatable property" . + . + . + . + . + "An EnumeratedActuatableProperty is a property with an enumerated (fixed) set of possible values that can be changed (actuated)." . + "Chiller" . + . + _:7fada94c9952b1f0c4416eadb44beaf3 . + _:41c88ec2cf6e8bd578a710dd80c3ddcb . + . + . + "A refrigerating machine used to transfer heat from fluids." . + "ElectricalVoltagePhases-CNLineNeutralVoltage" . + . + . + . + . + "Identifies the Line-to-neutral voltage is between phases C and N" . + "Liquid-Sub cooled" . + . + . + . + . + "Liquid-Sub cooled" . + "110V Voltage" . + . + . + . + . + . + . + "110V Voltage" . + . + "110"^^ . + "cnx" . + . + "The cnx relation is a symmetric property used to associate adjacent entities in a connection path (comprised of Equipment-ConnectionPoint-Connection-ConnectionPoint-Equipment sequences)." . + "CoolOnly" . + . + . + . + . + "CoolOnly" . + "AC-3000VLL-1730VLN-3Ph-60Hz" . + . + . + . + . + . + . + . + "AC-3000VLL-1730VLN-3Ph-60Hz" . + . + "hasRole" . + . + "The relation hasRole is used to indicate the role of an Equipment, Connection, ConnectionPoint, or System within a building (e.g., a heating coil will be associated with Role-Heating). Possible values are defined in EnumerationKind-Role (see `s223:EnumerationKind-Role`)." . + "AC-480VLL-277VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + "AC-480VLL-277VLN-1Ph-60Hz" . + . + "5V-Neg" . + . + . + . + . + . + . + "5V-Neg" . + "Aspect-Minimum" . + . + . + . + . + "The minimum allowable level of something characterized by this Property." . + "has member" . + . + "The relation hasMember associates a System with its component Equipment and/or Systems." . + "Electric transformer" . + . + _:ab14a3fae5b0f6558b9746935dccffa9 . + _:e32f3d917da2a5c8d943e7b9917ec10a . + . + . + "A piece of electrical equipment used to convert alternative current (AC) electric power from one voltage to another voltage." . + "DCNegativeVoltage-3.0V" . + . + . + . + . + . + . + "DCNegativeVoltage-3.0V" . + . + "48V-Pos" . + . + . + . + . + . + . + "48V-Pos" . + "Phase-Vapor" . + . + . + . + . + "Phase-Vapor" . + "1900V Voltage" . + . + . + . + . + . + . + "1900V Voltage" . + . + "1900"^^ . + "277V Line-Neutral Voltage" . + . + . + . + . + . + . + "277V Line-Neutral Voltage" . + . + "Role-Exhaust" . + . + . + . + . + "Role-Exhaust" . + "6000V Voltage" . + . + . + . + . + . + . + "6000V Voltage" . + . + "6000"^^ . + "Physical Space" . + . + _:1f6bda95f292f112ba7c4bf4c985a40d . + _:b8efa4f4f705f2e84c1caf51207bd84c . + . + . + "A PhysicalSpace is an architectural concept representing a room, a collection of rooms such as a floor, a part of a room, or any physical space that might not even be thought of as a room, such as a patio space or a roof." . + "Signal EIA485" . + . + . + . + . + "Signal EIA485" . + "Weekend" . + "Day of week-Weekend" . + . + . + . + . + "This class defines the EnumerationKind values of Saturday and Sunday" . + "Role-Primary" . + . + . + . + . + "Role-Primary" . + "Refrigerant-R-410A" . + . + . + . + . + "Refrigerant-R-410A" . + "EnumerationKind Binary" . + . + . + . + . + "This class has enumerated subclasses of True, False and Unknown used to describe the possible values of a binary property" . + "Window shade" . + . + . + . + "A window covering that can be moved to block out or allow in light. " . + "AC-231VLN-1Ph-50Hz" . + . + . + . + . + . + . + "AC-231VLN-1Ph-50Hz" . + . + "Aspect-Face" . + . + . + . + . + "The value of the associated Property identifies a property related to a face, e.g. Coil Face Velocity." . + "AC-208VLL-120VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + "AC-208VLL-120VLN-1Ph-60Hz" . + . + "Inlet Connection Point" . + . + _:f2c980d77abab96bb85c5ac404298ea9 . + . + . + "An InletConnectionPoint indicates that a substance must flow into the equipment or domain space at this connection point and cannot flow the other direction. An IntletConnectionPoint is a subclass of ConnectionPoint." . + "Aspect-Command" . + . + . + . + . + "Aspect-Command" . + "Role-Cooling" . + . + . + . + . + "Role-Cooling" . + "Role-Economizer" . + . + . + . + . + "Role-Economizer" . + "Aspect-Alarm" . + . + . + . + . + "Aspect-Alarm" . + "3460V Line-Neutral Voltage" . + . + . + . + . + . + . + "3460V Line-Neutral Voltage" . + . + "24V Voltage" . + . + . + . + . + . + . + "24V Voltage" . + . + "24"^^ . + "AC-2400VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-2400VLN-1Ph-60Hz" . + . + "AC-600VLL-3Ph-60Hz" . + . + . + . + . + . + . + "AC-600VLL-3Ph-60Hz" . + . + "277V Voltage" . + . + . + . + . + . + . + "277V Voltage" . + . + "277"^^ . + "AC-600VLL-347VLN-3Ph-60Hz" . + . + . + . + . + . + . + . + "AC-600VLL-347VLN-3Ph-60Hz" . + . + "Heat exchanger" . + . + _:c3ffe00ca344b5b6810a537a92608c56 . + _:9457936fcefe4db1c5d1f28f95e5ebe4 . + . + . + "A component intended to transfer heat from one medium to another while keeping the two media separate." . + "AC-480VLL-3Ph-60Hz" . + . + . + . + . + . + . + "AC-480VLL-3Ph-60Hz" . + . + "connected from" . + . + "The relation connectedFrom means that connectable things are connected with a specific flow direction. B is connectedFrom A, means a directionality beginning at A and ending at B. The inverse direction is indicated by connectedTo (see `s223:connectedTo`)." . + . + . + "Electrical Phase Identifier BC" . + . + . + . + . + "The value of the associated Property identifies the electrical phase BC of the Connection." . + "Domain-Lighting" . + . + . + . + . + "The domain Lighting represents equipment used to provide illumination within or outside a building. Example equipment that might fall within a Lighting domain includes luminaires, daylight sensors, and movable sun shades." . + "5V Voltage" . + . + . + . + . + . + . + "5V Voltage" . + . + "5"^^ . + "208V Voltage" . + . + . + . + . + . + . + "208V Voltage" . + . + "208"^^ . + "Zone group" . + . + _:cc9ade4ead3f887a27d67e3d6ed62839 . + _:61d82b7fda6687cc316c9035426c045b . + . + . + "A ZoneGroup is a logical grouping (collection) of Zones for some functional or system reason, to identify a domain of control, such as a Lighting Zone, or a heating zone." . + "24V-Pos" . + . + . + . + . + . + . + "24V-Pos" . + "AC-190VLL-3Ph-50Hz" . + . + . + . + . + . + . + "AC-190VLL-3Ph-50Hz" . + . + "Occupancy sensor" . + . + . + . + "An OccupancySensor is a subclass of a Sensor that observes a Property that represents measurement of occupancy in a space." . + "Aspect-Model" . + . + . + . + . + "The value of the associated Property identifies the model." . + "Medium" . + . + . + . + . + "This class has enumerated subclasses of a physical substance or anything that allows for the transfer of energy or information." . + "DCNegativeVoltage-2.5V" . + . + . + . + . + . + . + "DCNegativeVoltage-2.5V" . + . + "Radiant panel" . + . + _:fc51b951887184991ca68635f10efde9 . + . + . + "A heating or cooling surface that delivers 50% or more of its heat transfer by radiation." . + "Occupied" . + . + . + . + . + "Occupied" . + "Aspect-WetBulb" . + . + . + . + . + "The associated Property is a WetBulb temperature." . + "Fan" . + . + _:b0e292bf6bf32692d6a8462950127d88 . + _:e82c3066043810296918ff783ece4dab . + . + . + "A machine used to create flow within a gas such as air. " . + "AC-415VLL-240VLN-3Ph-50Hz" . + . + . + . + . + . + . + . + "AC-415VLL-240VLN-3Ph-50Hz" . + . + "ElectricalVoltagePhases-ANLineNeutralVoltage" . + . + . + . + . + "Identifies the Line-to-neutral voltage is between phases A and N" . + "DCPositiveVoltage-5.0V" . + . + . + . + . + . + . + "DCPositiveVoltage-5.0V" . + . + "Occupancy Presence" . + . + . + . + . + "This class has enumerated subclasses indicating whether physical presence is detected or not." . + "EnumerationKind Domain" . + . + . + . + . + "A Domain represents a categorization of building services or specialization used to characterize equipment or spaces in a building. Example domains include HVAC, Lighting, and Plumbing." . + "inverse of" . + . + "The relation inverseOf is a modeling construct to associate relations that are inverses of one another, such as connectedTo and connectedFrom." . + "A reference to the QuantityKind of a QuantifiableProperty of interest, e.g. quantitykind:Temperature." . + "contains" . + . + "The relation contains associates a PhysicalSpace or a piece of Equipment to a PhysicalSpace or another piece of Equipment, respectively." . + "has electrical phase" . + . + "The relation hasElectricalPhase is used to indicate the electrical phase identifier or the relevant electrical phases for a voltage difference for AC electricity inside a Connection." . + "AC-219VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-219VLN-1Ph-60Hz" . + . + "24V Line-Neutral Voltage" . + . + . + . + . + . + . + "24V Line-Neutral Voltage" . + . + "Steam" . + . + . + . + . + "Steam" . + "219V Voltage" . + . + . + . + . + . + . + "219V Voltage" . + . + "219"^^ . + "Compressor" . + . + _:d3008d253380e98d3a5274e4bbb5e232 . + _:edcb7c59d4b8d83d1aeafbb941403398 . + . + . + "A device for mechanically increasing the pressure of a gas." . + "AC-3000VLL-3Ph-60Hz" . + . + . + . + . + . + . + "AC-3000VLL-3Ph-60Hz" . + . + "has zone" . + . + "The relation hasZone is used to associate a ZoneGroup with the Zones that make up that ZoneGroup." . + "Outlet Connection Point" . + . + _:383d85ed5dfc61c58a2b3d6584181429 . + . + . + "An OutletConnectionPoint indicates that a substance must flow out of a Connectable (see 's223:Connectable') at this connection point and cannot flow in the other direction. An OutletConnectionPoint is a predefined subclass of ConnectionPoint." . + "12V" . + . + . + . + . + . + . + "This class has enumerated instances of all polarities of 12 volt electricity." . + "System" . + . + _:acf271b522b7f713d4920c33e9729e93 . + _:a103f74164f4edc05d87afe301a0eba3 . + . + . + "A System is a logical grouping (collection) of Equipment for some functional or system reason, such as a chilled water system, or HVAC system. A System does not participate in Connections." . + "Actuatable Property" . + . + . + . + "This class describes non-numeric properties of which real-time value can be modified by a user or a machine outside of the model." . + "DC Positive Voltage" . + . + . + . + . + . + . + "This class has enumerated instances of common positive voltages." . + . + "has number of electrical phases" . + . + "The relation hasNumberOfElectricalPhases is used to identify the number of electrical phases in an AC electricity enumeration kind. " . + "AC-10000VLL-1Ph-60Hz" . + . + . + . + . + . + . + "AC-10000VLL-1Ph-60Hz" . + . + "ElectricalVoltagePhases-ABLineLineVoltage" . + . + . + . + . + "Identifies the Line-to-line voltage is between phases A and B" . + "5770V Voltage" . + . + . + . + . + . + . + "5770V Voltage" . + . + "5770"^^ . + "Differential sensor" . + . + _:30ccced4086eb369393fde9e47890b97 . + . + . + "A sensor that measures the difference of a quantity between any two points in the system." . + _:e965591ed789adde0f1a115daea9db6a . + _:391acaf117a9469339fb0e23a1d83ca7 . + "Off" . + . + . + . + . + "Off" . + "ElectricalVoltagePhases-BCLineLineVoltage" . + . + . + . + . + "Identifies the Line-to-line voltage is between phases B and C" . + "Electricity" . + . + . + . + . + "This class has enumerated subclasses of all forms of electricity, including AC and DC." . + "AC-6000VLL-1Ph-60Hz" . + . + . + . + . + . + . + "AC-6000VLL-1Ph-60Hz" . + . + "Direction-Outlet"@en . + "Direction-Sortie"@fr . + . + . + . + . + "One member of the enumerated valid values to characterize the hasDirection property. It is an instance of the Direction class." . + "Aspect-Fault" . + . + . + . + . + "Aspect-Fault" . + "Presence-True" . + . + . + . + . + "Presence-True" . + "Turbine" . + . + _:81ea9795d9ceb83ac304bb0849a7e121 . + _:55f2000eaab60457da36ffd0c3231da8 . + . + . + "An energy transducer that converts mechanical energy into electric energy." . + "Property" . + . + _:2361862d313a24a7ae4ffefe8b3ef144 . + _:dddd9aa44f14625f247d6fcb8d41a69f . + _:8745e4b0372e5cc028c6024dfa19a16e . + _:36e7a18ce65cc04f24d4a67f6820a4c6 . + _:c2844109db8c8de4e55368b90bc553c6 . + _:471ac808d07065ea3dca6e53e251bcce . + . + . + "An attribute, quality, or characteristic of a feature of interest.\n\nThe Property class is the parent of all variations of a property, which are:\nActuatableProperty - parent of subclass of properties that can be modified by user or machine outside of the model (typically command);\nObservableProperty - parent of subclass of properties that can not be modified by user or machine outside of the model (typically measures);\nEnumerableProperty - parent of subclass of properties defined by EnumerationKind;\nQuantifiableProperty - parent of subclass of properties defined by numerical values.\n\nAnd their different associations :\nQuantifiableActuatableProperty,\nQuantifiableObservableProperty,\nEnumeratedObservableProperty,\nEnumeratedActuatableProperty.\n\nA QuantifiableProperty (or subClass thereof) must always be associated with a Unit and a QuantityKind, either explicitly from the Property, or through the associated Value. If the Unit is defined, the SHACL reasoner (if invoked) will figure out and assert the QuantityKind (the most general version).\n\nEnumerable properties must be associated with an EnumerationKind.\n" . + "AC-6600VLL-1Ph-60Hz" . + . + . + . + . + . + . + "AC-6600VLL-1Ph-60Hz" . + . + "AC-1730VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-1730VLN-1Ph-60Hz" . + . + "Air handling unit" . + . + _:ffc0d00dd61f654337d4e55ea6b3fb20 . + _:fe7166b35c6b720555082502b1575e89 . + . + . + "An assembly consisting of sections containing a fan or fans and other necessary equipment to perform one or more of the following functions: circulating, filtration, heating, cooling, heat recovery, humidifying, dehumidifying, and mixing of air. It is usually connected to an air-distribution system." . + "1730V Line-Neutral Voltage" . + . + . + . + . + . + . + "1730V Line-Neutral Voltage" . + . + "400V Line-Line Voltage" . + . + . + . + . + . + . + "400V Line-Line Voltage" . + . + "Position" . + . + . + . + . + "This class has enumerated subclasses of position such as closed or open." . + "AC-400VLL-3Ph-50Hz" . + . + . + . + . + . + . + "AC-400VLL-3Ph-50Hz" . + . + "HeatPump" . + . + _:2ae2b20100f422f7e964a96285a78bb7 . + _:b9ffa77955bdd15854905fff5b8fb9f9 . + . + . + "A device that can heat or cool by transferring thermal energy using a reversible refrigeration cycle." . + "190V Voltage" . + . + . + . + . + . + . + "190V Voltage" . + . + "190"^^ . + "AC-1900VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-1900VLN-1Ph-60Hz" . + . + "Role-Expansion" . + . + . + . + . + "Role-Expansion" . + "6V-Neg-6V-Pos" . + . + . + . + . + . + . + "6V-Neg-6V-Pos" . + "DCPositiveVoltage-48.0V" . + . + . + . + . + . + . + "DCPositiveVoltage-48.0V" . + . + "Role-Supply" . + . + . + . + . + "Role-Supply" . + "Presence-False" . + . + . + . + . + "Presence-False" . + "Electric breaker" . + . + _:a60fc713d7026579a20ada5031a727a8 . + . + . + "A piece of equipment designed to open the circuit automatically at a predetermined overcurrent without damage to itself (when properly applied within its rating)." . + "Fan Powered Air Terminal" . + . + _:f6e04ecf33c99bd3d7f949834eb8e332 . + . + . + "An air terminal containing a fan. Airflow may pass through or be parallel to the fan. These units may also have supplemental heating or cooling." . + "1900V Line-Neutral Voltage" . + . + . + . + . + . + . + "1900V Line-Neutral Voltage" . + . + "EM-Microwave" . + . + . + . + . + "EM-Microwave" . + "Power Over Ethernet Switch" . + . + _:776ce7e710880528030c442aac307913 . + _:2af4a987609a65fb221c0b0f30739534 . + _:34b430d7ff7c0f3bf5aad4ce56fac27e . + . + . + "A type of network hardware that connects and is capable of powering cabled devices, such as computers and Wi-Fi access points, in an Ethernet LAN so they can communicate with each other and to the internet." . + "Aspect-PowerFactor" . + . + . + . + . + "The power factor of something characterized by a dimensionless value of this Property." . + "OnOff enumeration" . + . + . + . + . + "This class has enumerated subclasses of states of either on or off." . + "Zone" . + . + _:bad220b3bb315bf684949169a4616319 . + _:8233c4ec3e3faf9dd3a32113f1069dec . + . + . + "A Zone is a logical grouping (collection) of domain spaces for some functional or system reason, to identify a domain of control, such as a Lighting Zone, or a heating zone" . + "Role-Return" . + . + . + . + . + "Role-Return" . + "Electricity-Neutral" . + . + . + . + . + "Electricity-Neutral" . + "Electric wire" . + . + _:f8f382c3f67e4995ce1b8535741ce96d . + _:fe5bcb89d2d196a84884f55f415db583 . + . + . + "An ElectricWire is a subclass of Connection, that represents one or more electrical conductors used to convey electricity." . + "Quantifiable Actuatable Property" . + . + . + . + . + "This class is for quantifiable properties of which numerical values are specified to be modifiable by a user or a machine outside of the model, like a setpoint." . + "6V-Neg" . + . + . + . + . + . + . + "6V-Neg" . + "Outdoor physical space" . + . + . + . + "An OutdoorPhysicalSpace is a subclass of PhysicalSpace to represent any physical spaces outside of a facility where, for example, ambient properties might be measured (within a suitably defined DomainSpace)." . + "of substance" . + . + "The relation ofSubstance is used to associate a Property with a specific Substance." . + "Occupancy Motion" . + . + . + . + . + "This class has enumerated subclasses indicating whether motion is detected or not." . + "Quantifiable Observable Property" . + . + . + . + . + "This class is for quantifiable properties of which numerical values cannot be modified by a user or a machine outside of the model, but only observed, like a temperature reading or a voltage measure." . + "hasValue" . + . + "hasValue is used to contain a fixed value that is part of a 223 model, rather than a computed, measured, or externally derived variable." . + "has observation location" . + . + "The relation hasObservationLocation associates a sensor to the topological location where it is observing the property (see `s223:observes`). The observation location can be a Connectable (see `s223:Connectable`), Connection (see `s223:Connection`), or ConnectionPoint (see `s223:ConnectioPoint`)." . + "AC-24VLN-1Ph-50Hz" . + . + . + . + . + . + . + "AC-24VLN-1Ph-50Hz" . + . + "Damper" . + . + _:e12925c55579ef2e80a4f393624214a6 . + _:70e08e39a71adad65aaa1468988f27b0 . + . + . + "An element inserted into an air-distribution system or element of an air-distribution system permitting modification of the air resistance of the system and consequently changing the airflow rate or shutting off the airflow." . + "3000V Line-Line Voltage" . + . + . + . + . + . + . + "3000V Line-Line Voltage" . + . + "AC-415VLL-3Ph-50Hz" . + . + . + . + . + . + . + "AC-415VLL-3Ph-50Hz" . + . + "347V Line-Neutral Voltage" . + . + . + . + . + . + . + "347V Line-Neutral Voltage" . + . + "AC-6600VLL-3Ph-60Hz" . + . + . + . + . + . + . + "AC-6600VLL-3Ph-60Hz" . + . + "3460V Voltage" . + . + . + . + . + . + . + "3460V Voltage" . + . + "3460"^^ . + "3810V Line-Neutral Voltage" . + . + . + . + . + . + . + "3810V Line-Neutral Voltage" . + . + "Controller" . + . + _:ee627d763ba6d47412a056eda1597a6f . + . + . + "A device for regulation of a system or component in normal operation, which executes a Function." . + "AC-4160VLL-2400VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + "AC-4160VLL-2400VLN-1Ph-60Hz" . + . + "AC-6000VLL-3Ph-60Hz" . + . + . + . + . + . + . + "AC-6000VLL-3Ph-60Hz" . + . + "connects from" . + . + "The relation connectsFrom binds a Connectable thing to a Connection with an implied directionality. B connectsFrom A indicates a flow from A to B." . + "Luminaire" . + . + _:25f4fd727753f32c48558851fec54400 . + _:a6877983d4d3f2df269e573b7e841896 . + . + . + "A complete lighting unit consisting of a lamp or lamps together with the housing designed to distribute the light, position and protect the lamps, and connect the lamps to the power supply." . + "Phase-Gas" . + . + . + . + . + "This class has enumerated subclasses of gas in various thermodynamic states." . + "AC-110VLN-1Ph-50Hz" . + . + . + . + . + . + . + "AC-110VLN-1Ph-50Hz" . + . + "Monday" . + . + . + . + . + "Monday" . + "Domain-Refrigeration" . + . + . + . + . + "The domain Refrigeration represents equipment used to provide cooling for a purpose other than space conditioning in a building." . + "Heating" . + . + . + . + . + "Heating" . + "110V Line-Neutral Voltage" . + . + . + . + . + . + . + "110V Line-Neutral Voltage" . + . + "Aspect-Standby" . + . + . + . + . + "The standby value of something characterized by this Property." . + "AC-24VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-24VLN-1Ph-60Hz" . + . + "Water-GlycolSolution" . + . + _:bf03f822d9618cc2561f96fd68963092 . + _:bcbb80f3b4303e46d075ca4b4a3ea897 . + _:beafdb1f2b27923f90a613548785a008 . + . + . + . + "This class has enumerated subclasses of water-glycol solutions in various concentrations." . + _:990119f7e78559dcb8c5059333b6670f . + _:7c54fb947753c917efc4b06ce9aafcf1 . + "Wednesday" . + . + . + . + . + "Wednesday" . + "Role-Discharge" . + . + . + . + . + "Role-Discharge" . + "Light-Ultraviolet" . + . + . + . + . + "Light-Ultraviolet" . + "has Physical Location" . + . + "The relation hasPhysicalLocation is used to indicate the PhysicalSpace (see `s223:PhysicalSpace`) where a piece of Equipment (see `s223:Equipment`) is located." . + "400V Voltage" . + . + . + . + . + . + . + "400V Voltage" . + . + "400"^^ . + "Saturday" . + . + . + . + . + "Saturday" . + "AC-400VLL-231VLN-1Ph-50Hz" . + . + . + . + . + . + . + . + "AC-400VLL-231VLN-1Ph-50Hz" . + . + "GlycolSolution-15Percent" . + . + . + . + . + "GlycolSolution-15Percent" . + _:ca089b7c4de3d9f294c6f5d90cd27d5c . + _:498e492a215af6cb76fbc11069f7d55e . + "3000V Voltage" . + . + . + . + . + . + . + "3000V Voltage" . + . + "3000"^^ . + "Enumerated observable property" . + . + . + . + . + "An EnumeratedObservableProperty is a property with an enumerated (fixed) set of possible values that cannot be changed (can only be observed)." . + "Signal-Modulated" . + . + . + . + . + "This class has enumerated subclasses of electric signals at various voltage ranges." . + "AC-480VLL-1Ph-60Hz" . + . + . + . + . + . + . + "AC-480VLL-1Ph-60Hz" . + . + "2.5V-Neg-2.5V-Pos" . + . + . + . + . + . + . + "2.5V-Neg-2.5V-Pos" . + "AC-3000VLL-1Ph-60Hz" . + . + . + . + . + . + . + "AC-3000VLL-1Ph-60Hz" . + . + "Photovoltaic module" . + . + _:c028fdd68f11aa336cd1e8455ca792ec . + _:3877bf4e809b8ee3acc4879105d028cd . + . + . + "A piece of equipment that converts sunlight into electricity." . + "2400V Voltage" . + . + . + . + . + . + . + "2400V Voltage" . + . + "2400"^^ . + "GlycolSolution-30Percent" . + . + . + . + . + "GlycolSolution-30Percent" . + _:68ad8506b6d0800c285962f12d36b2f7 . + _:bce65c594669063d2855e16eed0c3be9 . + "Off" . + . + . + . + . + "Off" . + "12V Voltage" . + . + . + . + . + . + . + "12V Voltage" . + . + "12"^^ . + "Observable Property" . + . + . + . + "This class describes non-numeric properties of which real-time value cannot be modified by a user or a machine outside of the model. Sensor readings are typically observable properties as their values naturally fluctuate, but are not meant to be modified by a user." . + "Role-Recirculating" . + . + . + . + . + "Role-Recirculating" . + "AC-5770VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-5770VLN-1Ph-60Hz" . + . + "Solar thermal collector" . + . + _:f2d7ece86a3c3a0a5ca58bf2e0768a86 . + _:85cb6f45c193d67f2e8c20f6c724bdb6 . + . + . + "A device that converts sunlight into thermal energy." . + "EM-RF" . + . + . + . + . + "EM-RF" . + "Electricity AC" . + . + . + . + _:e9d57840edc601830f5bd2626dad6c9f . + _:5b21e101d839343f42340562b13f2315 . + _:eaa53d454ba56f5ac47f59e4e56c13c3 . + . + . + . + "This class has enumerated instances of all AC forms of electricity." . + . + "120V Line-Neutral Voltage" . + . + . + . + . + . + . + "120V Line-Neutral Voltage" . + . + "DC Negative Voltage" . + . + . + . + . + . + . + "This class has enumerated instances of common negative voltages." . + . + "Motor" . + . + _:6c63e3be6fe841a65e312db5b1d9ddf . + . + . + "A machine in which power is applied to do work by the conversion of various forms of energy into mechanical force and motion." . + "Auto" . + . + . + . + . + "Auto" . + "12V-Neg-12V-Pos" . + . + . + . + . + . + . + "12V-Neg-12V-Pos" . + "Particulate-PM2.5" . + . + . + . + . + "Particulate-PM2.5" . + "Medium-Air" . + . + . + . + . + "This class has enumerated subclasses of Air in various states." . + "AC-380VLL-219VLN-3Ph-60Hz" . + . + . + . + . + . + . + . + "AC-380VLL-219VLN-3Ph-60Hz" . + . + "HeatOnly" . + . + . + . + . + "HeatOnly" . + "FanOnly" . + . + . + . + . + "FanOnly" . + "DCNegativeVoltage-48.0V" . + . + . + . + . + . + . + "DCNegativeVoltage-48.0V" . + . + "DCPositiveVoltage-24.0V" . + . + . + . + . + . + . + "DCPositiveVoltage-24.0V" . + . + "has observation location low" . + . + "The relation hasObservationLocationLow associates a differential sensor to one of the topological locations where a differential property is observed (see `s223:observes`)." . + . + "Off" . + . + . + . + . + "Off" . + "AC-3000VLL-1730VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + "AC-3000VLL-1730VLN-1Ph-60Hz" . + . + "Direction-Inlet"@en . + . + . + . + . + "One of the set of enumeration values for the hasDirection property used to characterize the direction of flow associated with an instance of a ConnectionPoint. The value Inlet indicates that the direction of flow is into the Equipment." . + "Substance-Soot" . + . + . + . + . + "Substance-Soot" . + "Active" . + . + . + . + . + "Active" . + "Symmetric property" . + . + . + . + "A SymmetricProperty is modeling construct used to define symmetric behavior for certain properties in the standard such as cnx and connected." . + "Dehumidifying" . + . + . + . + . + "Dehumidifying" . + "Humidity sensor" . + . + . + . + "A HumiditySensor is a specialization of a Sensor that observes a QuantifiableObservableProperty that represents a humidity measurement. " . + "3300V Voltage" . + . + . + . + . + . + . + "3300V Voltage" . + . + "3300"^^ . + "commanded by Property" . + . + "The relation actuatedByProperty binds an Actuator to the ActuatableProperty that it responds to. This Property will be owned by the equipment that it actuates (see `s223:actuates`)." . + "Device Identifier" . + . + "The Object_Identifier property of the device object within the BACnet device. See ASHRAE 135-2020 Clause 12.11.1." . + "Signal USB" . + . + . + . + . + "Signal USB" . + "Domain-Occupancy" . + . + . + . + . + "The domain Occupancy represents equipment used to determine if people are present in a space or count the number of people in a space." . + "Water-Hot water" . + . + . + . + . + "Water-Hot water" . + "connected" . + . + . + "The relation connected indicates that two connectable things are connected without regard to any directionality of a process flow. " . + "ElectricalVoltagePhases-CALineLineVoltage" . + . + . + . + . + "Identifies the Line-to-line voltage is between phases C and A" . + "Modulated 4-20mA" . + . + . + . + . + "Modulated 4-20mA" . + "2400V Line-Neutral Voltage" . + . + . + . + . + . + . + "2400V Line-Neutral Voltage" . + . + "AC-6000VLL-3460VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + "AC-6000VLL-3460VLN-1Ph-60Hz" . + . + "Particulate sensor" . + . + _:782e44e2f0542c955b72e4bae93b4650 . + . + . + "A ParticulateSensor is a specialization of a Sensor that observes a QuantifiableObservableProperty that represents a particulate concentration measurement." . + "Single Phase AC Electricity" . + . + . + . + . + . + "Single Phase AC Electricity" . + . + "1"^^ . + "Humidifier" . + . + . + . + "A piece of equipment to add moisture to a gas such as air." . + "Phase-Liquid" . + . + . + . + . + "This class has enumerated subclasses of liquid in various thermodynamic states." . + "AC-3300VLL-3Ph-60Hz" . + . + . + . + . + . + . + "AC-3300VLL-3Ph-60Hz" . + . + "Aspect-DryBulb" . + . + . + . + . + "The associated Property is a DryBulb temperature." . + "10000V Line-Line Voltage" . + . + . + . + . + . + . + "10000V Line-Line Voltage" . + . + "600V Voltage" . + . + . + . + . + . + . + "600V Voltage" . + . + "600"^^ . + "DCPositiveVoltage-6.0V" . + . + . + . + . + . + . + "DCPositiveVoltage-6.0V" . + . + "DCPositiveVoltage-2.5V" . + . + . + . + . + . + . + "DCPositiveVoltage-2.5V" . + . + "Sunday" . + . + . + . + . + "Sunday" . + "6600V Voltage" . + . + . + . + . + . + . + "6600V Voltage" . + . + "6600"^^ . + "12V-Pos" . + . + . + . + . + . + . + "12V-Pos" . + "Domain-HVAC" . + . + . + . + . + "The domain HVAC represents equipment used to provide space conditioning and ventilation within a building. Example equipment that might fall within an HVAC domain include fans, pumps, air-handling units, and variable air volume boxes. " . + "Thermostat" . + . + . + . + "An automatic control device used to maintain temperature at a fixed or adjustable setpoint." . + "AC-240VLL-1Ph-50Hz" . + . + . + . + . + . + . + "AC-240VLL-1Ph-50Hz" . + . + "127V Line-Neutral Voltage" . + . + . + . + . + . + . + "127V Line-Neutral Voltage" . + . + "AC-3810VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-3810VLN-1Ph-60Hz" . + . + "Pressure sensor" . + . + . + . + "A PressureSensor is a specialization of a Sensor that observes a QuantifiableObservableProperty that represents a pressure measurement." . + "HVAC operating status" . + . + . + . + . + "HVACOperatingStatus has enumerated subclasses of the HVAC system/equipment operating status." . + "Chilled beam" . + . + _:ff3ad289ed1e44b3924027ab7f357fab . + _:a9c6455a615bb66c955580e954327e5 . + _:a523440f57370b4f362942074714c1fe . + . + . + "A structure with a colder surface temperature where air passes through, and air movement is induced in the room to achieve cooling. Cooling medium is generally water." . + "Phase-Solid" . + . + . + . + . + "Phase-Solid" . + "Aspect-Effectiveness" . + . + . + . + . + "This class enumerates the possible states of effectiveness" . + "High" . + . + . + . + . + "High" . + "AC-4160VLL-1Ph-60Hz" . + . + . + . + . + . + . + "AC-4160VLL-1Ph-60Hz" . + . + "has domain space" . + . + "The relation hasDomainSpace is used to associate a Zone with the DomainSpace(s) that make up that Zone." . + "Electrical Phase Identifier AB" . + . + . + . + . + "The value of the associated Property identifies the electrical phase AB of the Connection." . + "Dual duct air terminal." . + . + . + _:dcf6d4c24612142f8dc4798163790b02 . + . + . + "A dual duct air terminal mixes two independent sources of primary air." . + "Substance" . + . + _:90e34a75456cb45f8b72d3d36e81c7d2 . + . + . + . + "This class has enumerated subclasses of the substances that are consumed, produced, transported, sensed, controlled or otherwise interacted with (e.g. water, air, etc.)." . + "Unknown" . + . + . + . + . + "Unknown" . + "Quantifiable Property" . + . + . + _:5b0571e4b9ae8a06d321771736411e62 . + _:3af606ef989ada86800dcd4e2b5dae4b . + _:95302b2acdbf4eaff70d310aeaf97f19 . + . + . + "This class is for quantifiable values that describe an object (System, Equipment, etc.) that are typically static (hasValue). That is, they are neither measured nor specified in the course of operations." . + "AC-10000VLL-5770VLN-1Ph-60Hz" . + . + . + . + . + . + . + . + "AC-10000VLL-5770VLN-1Ph-60Hz" . + . + "Substance-CO" . + . + . + . + . + "Substance-CO" . + . + "Created with TopBraid Composer" . + "Duct" . + . + . + . + "A Duct is a subclass of Connection, that represents a conduit through which air is conveyed." . + "Domain-ConveyanceSystems" . + . + . + . + . + "The domain ConveyanceSystems represents equipment used to move people or things from one place in a building to another. Example equipment that might fall within a ConveyanceSystems domain include elevators, escalators, and conveyer belts." . + "6V Voltage" . + . + . + . + . + . + . + "6V Voltage" . + . + "6"^^ . + "Equipment" . + . + _:c95bd65215e4f928ae9f64cdc28c0859 . + _:faf83c9e65765582e57bcf9221c5b426 . + _:6ae15f291b925142ba177942af03803e . + _:f2e019faf42fcdf80c919249127c95a6 . + _:46812907fd0fa7541e988fa73b443666 . + . + . + "\nAn Equipment is the modeling construct used to represent a mechanical device designed to accomplish a specific task, \nor a complex device that contains component pieces of Equipment. Unlike a System, Equipment can have ConnectionPoints and participate \nin the flow of one or more kinds of Medium. Examples of possible equipment include a Pump, Fan, HeatExchanger, Luminaire, \nTemperatureSensor, FlowSensor or more complex examples such as a chilled water plant.\nThe graphical depiction of Equipment used in this standard is a rounded cornered rectangle as show in Figure 5-1.\n\n![Graphical Depiction of Equipment.](figures/Figure_5-1Graphical_Depiciton_of_Equipment.svg)\n " . + "Aspect-Low limit" . + . + . + . + . + "Aspect-Low limit" . + "24V-Neg" . + . + . + . + . + . + . + "24V-Neg" . + "has thermodynamic phase" . + . + "The relation hasThermodynamicPhase is used to indicate the thermodynamic phase of the Medium inside a Connection." . + "Occupancy status" . + . + . + . + . + "This class has enumerated subclasses of occupancy status, i.e. the state of being used or occupied. Some Occupancy enumerations have subclasses for more specific use." . + "has enumeration kind" . + . + "The relation hasEnumerationKind associates an EnumerableProperty with a class of enumeration values. This is used to, for example, identify what kind of substance is transported along a Connection or which day of the week a setpoint is active." . + "AC-220VLL-3Ph-50Hz" . + . + . + . + . + . + . + "AC-220VLL-3Ph-50Hz" . + . + "AC-220VLL-1Ph-50Hz" . + . + . + . + . + . + . + "AC-220VLL-1Ph-50Hz" . + . + "Domain-Networking" . + . + . + . + . + "The domain Networking represents equipment used to provide information technology communication for a building." . + "On" . + . + . + . + . + "On" . + "AC-400VLL-231VLN-3Ph-50Hz" . + . + . + . + . + . + . + . + "AC-400VLL-231VLN-3Ph-50Hz" . + . + "600V Line-Line Voltage" . + . + . + . + . + . + . + "600V Line-Line Voltage" . + . + "has constituent" . + . + "The relation hasConstituent is used to indicate what substances constitute a material. The possible values are defined in EnumerationKind-Substance (see `s223:EnumerationKind-Substance`)." . + "380V" . + . + . + . + . + . + . + "This class has enumerated instances of all polarities of 380 volt electricity." . + "DCNegativeVoltage-12.0V" . + . + . + . + . + . + . + "DCNegativeVoltage-12.0V" . + . + "AC-415VLL-1Ph-50Hz" . + . + . + . + . + . + . + "AC-415VLL-1Ph-50Hz" . + . + "Pipe" . + . + . + . + "A Pipe is a subclass of Connection, that represents a hollow cylinder of metal or other material used to convey a Medium." . + "Duv sensor" . + . + . + . + "A subclass of LightSensor that observes the deviation of the light spectrum from pure blackbody." . + "3300V Line-Line Voltage" . + . + . + . + . + . + . + "3300V Line-Line Voltage" . + . + "Cooling tower" . + . + _:2ff289a7236f40b979caa174c1385867 . + _:dfe5e8bdfb3e2a78d754d4023229a6d1 . + . + . + "A heat transfer device in which atmospheric air cools warm water, generally by direct contact via evaporation." . + "Thursday" . + . + . + . + . + "Thursday" . + "190V Line-Line Voltage" . + . + . + . + . + . + . + "190V Line-Line Voltage" . + . + "Aspect-Electrical Voltage Phases" . + . + . + . + . + "This class enumerates the relevant electrical phases for a voltage difference for AC electricity inside a Connection." . + "AC-277VLN-1Ph-60Hz" . + . + . + . + . + . + . + "AC-277VLN-1Ph-60Hz" . + . + "Connection" . + . + _:297ae959e6f1fd67be6f2cd69c71eb38 . + _:59ce820ed314c86968b68dcdf29686a . + _:432e06ca6e8d6b058d7f9128591c4366 . + _:88d9d839119ffb8a63eb25ff4188ae34 . + _:200f69533a7838a9e5c2a5965e20e147 . + _:1e7f4fd378689e508fa386218911397d . + _:871195daec5d6a53f7b1eac6fcadd922 . + . + . + "A Connection is the modeling construct used to represent a physical thing (e.g., pipe, duct, or wire) that is used to convey some Medium (e.g., water, air, or electricity), or a virtual connection to convey electromagnetic radiation (e.g. light or wifi signal) between two connectable things. All Connections have two or more ConnectionPoints bound to either Equipment (see `s223:Equipment`), DomainSpace (see `s223:DomainSpace`), or Junction (see `s223:Junction`) See Figure 6-2. If the direction of flow is constrained, that constraint is indicated by using one or more InletConnectionPoints (see `s223:InletConnectionPoint`) to represent the inflow points and OutletConnectionPoints (see `s223:OutletConnectionPoint`) to represent the outflow points.\n \nA Connection may contain branches or intersections. These may be modeled using Junctions if it is necessary to identify a specific intersection. (see `s223:Junction`).\n\n![Graphical Depiction of Connection.](figures/Figure_5-3_Connection.svg)\n" . + "208V Line-Line Voltage" . + . + . + . + . + . + . + "208V Line-Line Voltage" . + . + "Off" . + . + . + . + . + "Off" . + "Class" . + . + . + . + "This is a modeling construct. All classes defined in the 223 standard are instances of s223:Class rather than owl:Class." . + "Signal Ethernet" . + . + . + . + . + "Signal Ethernet" . +_:f6e04ecf33c99bd3d7f949834eb8e332 . +_:f6e04ecf33c99bd3d7f949834eb8e332 _:f4840bae71c5c644e589750b9c71a280 . +_:f6e04ecf33c99bd3d7f949834eb8e332 "A FanPoweredTerminal must be associated with at least one Fan by using the relation contains." . +_:f6e04ecf33c99bd3d7f949834eb8e332 "1"^^ . +_:f6e04ecf33c99bd3d7f949834eb8e332 "1"^^ . +_:71f6b6ed3e6d1d51c7a545330a0e4a24 . +_:71f6b6ed3e6d1d51c7a545330a0e4a24 . +_:71f6b6ed3e6d1d51c7a545330a0e4a24 "An EnumerationKind-Numerical must be associated with at least one QuantityKind using the relation hasQuantityKind." . +_:71f6b6ed3e6d1d51c7a545330a0e4a24 "1"^^ . +_:1fd50bcac54113ccc4ca352d03a3860e . +_:1fd50bcac54113ccc4ca352d03a3860e _:58c651d63fe7c32bcd9db4bac457f4c0 . +_:ff2455033f89fa0891f48b239f9862bc . +_:ff2455033f89fa0891f48b239f9862bc _:f615cfd3983bb68d815e7786423b3f72 . +_:78261b5183a880c23749a0c4339134af . +_:6b8e6dc753e1bb2cfbc4a403fd6fc69b . +_:6b8e6dc753e1bb2cfbc4a403fd6fc69b _:90167de3152c17f1c899809c4ac01651 . +_:25f4fd727753f32c48558851fec54400 . +_:25f4fd727753f32c48558851fec54400 _:72c1f39a0eddd170f1eada49e1aa272d . +_:25f4fd727753f32c48558851fec54400 "A Luminaire shall have at least one outlet using the medium EM-Light." . +_:25f4fd727753f32c48558851fec54400 "1"^^ . +_:25f4fd727753f32c48558851fec54400 "1"^^ . +_:5b0571e4b9ae8a06d321771736411e62 . +_:5b0571e4b9ae8a06d321771736411e62 "s223: A QuantifiableProperty must be associated with at least one QuantityKind using the relation hasQuantityKind." . +_:5b0571e4b9ae8a06d321771736411e62 . +_:5b0571e4b9ae8a06d321771736411e62 "A QuantifiableProperty must be associated with at least one QuantityKind using the relation hasQuantityKind." . +_:5b0571e4b9ae8a06d321771736411e62 "1"^^ . +_:990119f7e78559dcb8c5059333b6670f "Unspecified" . +_:990119f7e78559dcb8c5059333b6670f . +_:990119f7e78559dcb8c5059333b6670f . +_:990119f7e78559dcb8c5059333b6670f . +_:990119f7e78559dcb8c5059333b6670f . +_:ae80952ade8b41cc229621215a735c59 . +_:ae80952ade8b41cc229621215a735c59 _:1846be8a2d082f645ab7d5e3ddca6505 . +_:ae80952ade8b41cc229621215a735c59 "A Furnace shall have at least one outlet using the medium Air." . +_:ae80952ade8b41cc229621215a735c59 "1"^^ . +_:ae80952ade8b41cc229621215a735c59 "1"^^ . +_:dcf6d4c24612142f8dc4798163790b02 . +_:dcf6d4c24612142f8dc4798163790b02 _:c4214af0abbb5beca9379d5d01821698 . +_:dcf6d4c24612142f8dc4798163790b02 "A DualDuctTerminal shall have at least two inlets using the medium Air." . +_:dcf6d4c24612142f8dc4798163790b02 "2"^^ . +_:dcf6d4c24612142f8dc4798163790b02 "2"^^ . +_:c3ffe00ca344b5b6810a537a92608c56 . +_:c3ffe00ca344b5b6810a537a92608c56 . +_:c3ffe00ca344b5b6810a537a92608c56 "If the relation hasRole is present it must associate the HeatExchanger with a EnumerationKind-Role." . +_:9877b89127935c910b355862d14bc93d . +_:22ec97cf643b6108574d2ae5246df358 . +_:22ec97cf643b6108574d2ae5246df358 . +_:948e19725528b0bd793d11d7a4ba249f "Unspecified" . +_:948e19725528b0bd793d11d7a4ba249f . +_:948e19725528b0bd793d11d7a4ba249f . +_:57d2eaa39462db87a80b58f10b5d5653 . +_:57d2eaa39462db87a80b58f10b5d5653 . +_:57d2eaa39462db87a80b58f10b5d5653 "If the relation actuates is present it must associate the Actuator with a Equipment." . +_:fca3ee78a59606175a5f5c58dc814224 . +_:fca3ee78a59606175a5f5c58dc814224 _:7c20ffa07b6ad02f778eed39f002b0f7 . +_:ab0bca7c1c0522f3fb41282e88e3181e . +_:ab0bca7c1c0522f3fb41282e88e3181e _:f5cf8bc08a5c64ca7c023523b0d28d52 . +_:ab0bca7c1c0522f3fb41282e88e3181e "An Inverter shall have at least one outlet using the medium Electricity-AC." . +_:ab0bca7c1c0522f3fb41282e88e3181e "1"^^ . +_:ab0bca7c1c0522f3fb41282e88e3181e "1"^^ . +_:b81743758ff9978924b3932cd554bb05 _:62fd1f774b4dfac01ba6a8e1334941cd . +_:198fb87dfd7cc9b9dbecfba86c857f06 . +_:198fb87dfd7cc9b9dbecfba86c857f06 . +_:be2f2a44666b1c9f94e8939cebf62765 _:fcb7d3116df6bd1302e0ae2aab11a003 . +_:be2f2a44666b1c9f94e8939cebf62765 _:a5ffb6a87f3ee8ca58ec615fff43b551 . +_:4a6c14a5915338c79d51cb0d573ea3cf . +_:4a6c14a5915338c79d51cb0d573ea3cf _:5a9a7dc845aadb26061d0b0f0d2b1059 . +_:d1ef7b42cca02f81978c4ece6646de8 . +_:d1ef7b42cca02f81978c4ece6646de8 . +_:d1ef7b42cca02f81978c4ece6646de8 "One of the constituents of PoE must be Ethernet." . +_:e9d57840edc601830f5bd2626dad6c9f . +_:e9d57840edc601830f5bd2626dad6c9f . +_:e9d57840edc601830f5bd2626dad6c9f "An electricity AC medium must have a frequency" . +_:e9d57840edc601830f5bd2626dad6c9f "1"^^ . +_:b28378600bd46643d04d2f864df09328 . +_:b28378600bd46643d04d2f864df09328 _:6e3479cf2caf67ad840d852fd2a007a6 . +_:5b21e101d839343f42340562b13f2315 . +_:5b21e101d839343f42340562b13f2315 "An electricity AC medium must have a voltage." . +_:5b21e101d839343f42340562b13f2315 _:f61f5d19a6227622e709587b13b154bf . +_:5b21e101d839343f42340562b13f2315 "1"^^ . +_:a6877983d4d3f2df269e573b7e841896 . +_:a6877983d4d3f2df269e573b7e841896 _:ef6d9401760da680fe75f1c933458565 . +_:a6877983d4d3f2df269e573b7e841896 "A Luminaire shall have at least one inlet using the medium Electricity." . +_:a6877983d4d3f2df269e573b7e841896 "1"^^ . +_:a6877983d4d3f2df269e573b7e841896 "1"^^ . +_:33db8cf03fb49a250e5895a1b5088205 _:1162af531f24bd6fd5d8b8e2ae5b80fb . +_:81ea9795d9ceb83ac304bb0849a7e121 . +_:81ea9795d9ceb83ac304bb0849a7e121 . +_:81ea9795d9ceb83ac304bb0849a7e121 "A Turbine shall have at least one outlet using the medium Electricity." . +_:81ea9795d9ceb83ac304bb0849a7e121 "1"^^ . +_:81ea9795d9ceb83ac304bb0849a7e121 _:eb057ab8226ecfea2882af6de48ff9e5 . +_:68ad8506b6d0800c285962f12d36b2f7 "Glycol conc" . +_:68ad8506b6d0800c285962f12d36b2f7 . +_:68ad8506b6d0800c285962f12d36b2f7 . +_:68ad8506b6d0800c285962f12d36b2f7 . +_:68ad8506b6d0800c285962f12d36b2f7 . +_:68ad8506b6d0800c285962f12d36b2f7 "30"^^ . +_:ca089b7c4de3d9f294c6f5d90cd27d5c "Glycol conc" . +_:ca089b7c4de3d9f294c6f5d90cd27d5c . +_:ca089b7c4de3d9f294c6f5d90cd27d5c . +_:ca089b7c4de3d9f294c6f5d90cd27d5c . +_:ca089b7c4de3d9f294c6f5d90cd27d5c . +_:ca089b7c4de3d9f294c6f5d90cd27d5c "15"^^ . +_:c028fdd68f11aa336cd1e8455ca792ec . +_:c028fdd68f11aa336cd1e8455ca792ec _:e7f846f90db5b85d96b780ebd1705b97 . +_:c028fdd68f11aa336cd1e8455ca792ec "An PhotovoltaicModule must have at least one inlet using the medium EM-Light." . +_:c028fdd68f11aa336cd1e8455ca792ec "1"^^ . +_:c028fdd68f11aa336cd1e8455ca792ec "1"^^ . +_:134d2824c4419ac89ea2165f6ae35ef3 . +_:134d2824c4419ac89ea2165f6ae35ef3 . +_:134d2824c4419ac89ea2165f6ae35ef3 "A Sensor must be associated with exactly 1 of QuantifiableObservableProperty or EnumeratedObservableProperty using the relation observes." . +_:134d2824c4419ac89ea2165f6ae35ef3 "1"^^ . +_:134d2824c4419ac89ea2165f6ae35ef3 "1"^^ . +_:2e6eaeceb84feca056596416246b178b . +_:2e6eaeceb84feca056596416246b178b . +_:32b6feff9dbe82491197d4acd5f0d418 . +_:32b6feff9dbe82491197d4acd5f0d418 . +_:32b6feff9dbe82491197d4acd5f0d418 "One of the constituents of a Water-GlycolSolution must be Medium-Water." . +_:5c356b80419b2eec751643315596108c . +_:2361862d313a24a7ae4ffefe8b3ef144 . +_:2361862d313a24a7ae4ffefe8b3ef144 . +_:2361862d313a24a7ae4ffefe8b3ef144 "If the relation hasAspect is present, it must associate the Property with an EnumerationKind." . +_:18fe7900b9011f367e3422222a76891a . +_:18fe7900b9011f367e3422222a76891a . +_:18fe7900b9011f367e3422222a76891a "If the relation connected is present it must associate the Connectable with a Connectable." . +_:18fe7900b9011f367e3422222a76891a "SymmetricConnectableToConnectableShape" . +_:fd2aeb5a8c51bdabeb7f2f19a80b863a . +_:fd2aeb5a8c51bdabeb7f2f19a80b863a . +_:3af606ef989ada86800dcd4e2b5dae4b . +_:3af606ef989ada86800dcd4e2b5dae4b . +_:3af606ef989ada86800dcd4e2b5dae4b "s223: A QuantifiableProperty must be associated with at least one Unit using the relation hasUnit." . +_:3af606ef989ada86800dcd4e2b5dae4b . +_:3af606ef989ada86800dcd4e2b5dae4b "A QuantifiableProperty must be associated with at least one Unit using the relation hasUnit." . +_:3af606ef989ada86800dcd4e2b5dae4b "1"^^ . +_:38ed484f44885055ee9dbb7ffc4d6ca3 . +_:38ed484f44885055ee9dbb7ffc4d6ca3 . +_:38ed484f44885055ee9dbb7ffc4d6ca3 "There must be at least two Properties that characterize the constituents of Power over Ethernet." . +_:38ed484f44885055ee9dbb7ffc4d6ca3 "2"^^ . +_:1aa69977ba2e5234b9e5c13aa5b0af88 . +_:1aa69977ba2e5234b9e5c13aa5b0af88 . +_:1aa69977ba2e5234b9e5c13aa5b0af88 "An AbstractSensor must be associated with exactly one ObservableProperty using the relation observes." . +_:1aa69977ba2e5234b9e5c13aa5b0af88 "1"^^ . +_:1aa69977ba2e5234b9e5c13aa5b0af88 "1"^^ . +_:e4ea2785e2693bdf93b78b256c5ea050 _:46fa56f66107af8a46f162f3f852840e . +_:e4ea2785e2693bdf93b78b256c5ea050 _:243b218e66e4b92119b04af8d01d20b . +_:309dedbd78bb9b9d193c510c10bb469a _:b4791d5544102ab47bc74763fb8f1b3b . +_:b0e292bf6bf32692d6a8462950127d88 . +_:b0e292bf6bf32692d6a8462950127d88 _:d5fd5582e3e8ee34d2986e513d3f525b . +_:b0e292bf6bf32692d6a8462950127d88 "A Fan shall have at least one inlet using the medium Air." . +_:b0e292bf6bf32692d6a8462950127d88 "1"^^ . +_:b0e292bf6bf32692d6a8462950127d88 "1"^^ . +_:1f761faeff16fdbe0f496f248b4ea878 . +_:1f761faeff16fdbe0f496f248b4ea878 _:c5b5c88da965894e8072dba041389c59 . +_:9dc0a9c97be700ac1f7bcd220749eea9 . +_:9dc0a9c97be700ac1f7bcd220749eea9 . +_:e965591ed789adde0f1a115daea9db6a _:be2f2a44666b1c9f94e8939cebf62765 . +_:e965591ed789adde0f1a115daea9db6a _:5fb821d6a0a26ddfdd9b9ecd790a5a65 . +_:c95889bc4445eb27d9fd83524e3ecb85 . +_:c95889bc4445eb27d9fd83524e3ecb85 . +_:c5b5c88da965894e8072dba041389c59 _:fbcc130cef713d84a3d95394e21ae6ad . +_:3877bf4e809b8ee3acc4879105d028cd . +_:3877bf4e809b8ee3acc4879105d028cd _:1f761faeff16fdbe0f496f248b4ea878 . +_:3877bf4e809b8ee3acc4879105d028cd "An PhotovoltaicModule shall have at least one outlet using the medium Electricity." . +_:3877bf4e809b8ee3acc4879105d028cd "1"^^ . +_:3877bf4e809b8ee3acc4879105d028cd "1"^^ . +_:bb1577bcf2d8b653f68dc3214bb0f34 . +_:bb1577bcf2d8b653f68dc3214bb0f34 . +_:bb1577bcf2d8b653f68dc3214bb0f34 "One of the constituents of a Water-GlycolSolution must be Medium-Glycol." . +_:8fcce3264757cbb422671b44fee9dee . +_:8fcce3264757cbb422671b44fee9dee . +_:3f00d64f1ce1823bcc6ab86716f2f1d0 . +_:3f00d64f1ce1823bcc6ab86716f2f1d0 . +_:cc9ade4ead3f887a27d67e3d6ed62839 . +_:cc9ade4ead3f887a27d67e3d6ed62839 "s223: A ZoneGroup must be associated with at least one Zone using the relation hasZone." . +_:cc9ade4ead3f887a27d67e3d6ed62839 . +_:cc9ade4ead3f887a27d67e3d6ed62839 "A ZoneGroup must be associated with at least one Zone using the relation hasZone." . +_:cc9ade4ead3f887a27d67e3d6ed62839 "1"^^ . +_:1ee8ef6dd5c14e8b99794a1cb46a9572 . +_:1ee8ef6dd5c14e8b99794a1cb46a9572 _:cee8b7ad6f12c6f1e67bacbb18156453 . +_:1ee8ef6dd5c14e8b99794a1cb46a9572 "A Boiler shall have at least one outlet using the medium Water." . +_:1ee8ef6dd5c14e8b99794a1cb46a9572 "1"^^ . +_:1ee8ef6dd5c14e8b99794a1cb46a9572 "1"^^ . +_:d52d5ebf82e9586318e7c244d31e5c01 . +_:d52d5ebf82e9586318e7c244d31e5c01 . +_:d52d5ebf82e9586318e7c244d31e5c01 "A heating coil must be related to the role 'Role-Heating' using the relation 'hasRole'." . +_:d52d5ebf82e9586318e7c244d31e5c01 "1"^^ . +_:a855ac793627d2d83563a3b96fffc38a . +_:a855ac793627d2d83563a3b96fffc38a _:33d3c725c2e685d00c51c8e9c4ca3e . +_:e9ad08ac8292a46744ae8131053ea707 _:fd2aeb5a8c51bdabeb7f2f19a80b863a . +_:7fada94c9952b1f0c4416eadb44beaf3 . +_:7fada94c9952b1f0c4416eadb44beaf3 _:f0753d2614467f1c6ef341dafdd0a48f . +_:7fada94c9952b1f0c4416eadb44beaf3 "A Chiller shall have at least one inlet using the medium Water." . +_:7fada94c9952b1f0c4416eadb44beaf3 "1"^^ . +_:7fada94c9952b1f0c4416eadb44beaf3 "1"^^ . +_:5adac3eafc9b6113b17a15ac6f9ddddb _:a7d9430efd13a713cfa3f04957db368a . +_:eaa53d454ba56f5ac47f59e4e56c13c3 . +_:eaa53d454ba56f5ac47f59e4e56c13c3 . +_:eaa53d454ba56f5ac47f59e4e56c13c3 "An electricity AC medium must have a number of electrical phases." . +_:eaa53d454ba56f5ac47f59e4e56c13c3 "1"^^ . +_:e9f45fa42723dde6b5aec375efd03ba0 _:cb222ed8a00712ef05ad278dadccae29 . +_:2682b861a152094e936eb1f5561b55 _:db41305265e9e477ecde7deedf1f5773 . +_:d5fd5582e3e8ee34d2986e513d3f525b . +_:d5fd5582e3e8ee34d2986e513d3f525b _:d65a5d56f3822a1dbe8f073922a61c3e . +_:d8fc1cb6e3b52f75be0c34ca34fe7596 . +_:fe7462fe1e3c83b43da1fd809e4ed55f _:1fd50bcac54113ccc4ca352d03a3860e . +_:fe7462fe1e3c83b43da1fd809e4ed55f _:feae27801a522fd06eb92e99e1225c43 . +_:129898ffa8193b87bca9d8375bf5c2b . +_:129898ffa8193b87bca9d8375bf5c2b _:bc67586b701df3822b6c6efd44b90f46 . +_:2338c23bfe24ce6479a6f5e8d16dbb30 . +_:6b6bb7bd06df16720ac6f9b942c5c084 _:bb1577bcf2d8b653f68dc3214bb0f34 . +_:6b6bb7bd06df16720ac6f9b942c5c084 _:466de7655987cee55a73e2884aba8e29 . +_:6fa6788f50eb19c2b148183a50796025 . +_:6fa6788f50eb19c2b148183a50796025 . +_:6fa6788f50eb19c2b148183a50796025 "A cooling coil must be related to the role 'Role-Cooling' using the relation 'hasRole'." . +_:6fa6788f50eb19c2b148183a50796025 "1"^^ . +_:d3008d253380e98d3a5274e4bbb5e232 . +_:d3008d253380e98d3a5274e4bbb5e232 _:c1cc1d3db370ba27cf55f71c6fcaf3ed . +_:d3008d253380e98d3a5274e4bbb5e232 "A Compressor shall have at least one inlet." . +_:d3008d253380e98d3a5274e4bbb5e232 "1"^^ . +_:d3008d253380e98d3a5274e4bbb5e232 "1"^^ . +_:f01077899fe376410cc4a07e5ff882c2 . +_:f01077899fe376410cc4a07e5ff882c2 . +_:c4f550b6b8f13455f3e0bce84222820c . +_:c4f550b6b8f13455f3e0bce84222820c _:421f967b825e0f8b07e1c59fa3fd9272 . +_:a0e0e7d217bc1acc9c9ae241695aaf27 . +_:a0e0e7d217bc1acc9c9ae241695aaf27 _:d8fc1cb6e3b52f75be0c34ca34fe7596 . +_:a55b6296a3d5a6a5fab831b5267fc513 . +_:a55b6296a3d5a6a5fab831b5267fc513 _:9f9eba976390bc7ea5cf11ef0f724d4d . +_:a55b6296a3d5a6a5fab831b5267fc513 "A TwoWayValve shall have at least one outlet." . +_:a55b6296a3d5a6a5fab831b5267fc513 "1"^^ . +_:a55b6296a3d5a6a5fab831b5267fc513 "1"^^ . +_:db31657720e710779bf647f5b9fb465d . +_:db31657720e710779bf647f5b9fb465d _:93e730cdd7c302128e3b63f8479c4d6f . +_:daaad51b1c141b833f45c6246d075ccf _:fcac579569ab26f0d656cb966ebd4848 . +_:d3fcc33f1747b12bca9ca14e7bdf57c5 . +_:d3fcc33f1747b12bca9ca14e7bdf57c5 _:2b7af2df6fe6800238363b6b8949342b . +_:54dceda577190e4943006c5c2d33af9b _:6dc32855ccc2d33fe259e6d3cd417770 . +_:1c64d4406c3b1bf3c4c1f41c4117e571 . +_:1c64d4406c3b1bf3c4c1f41c4117e571 _:ff07f3f3dfc150bfb82905f739b8f148 . +_:1c64d4406c3b1bf3c4c1f41c4117e571 "A FumeHood shall have at least one outlet using the medium Air." . +_:1c64d4406c3b1bf3c4c1f41c4117e571 "1"^^ . +_:1c64d4406c3b1bf3c4c1f41c4117e571 "1"^^ . +_:ff3ad289ed1e44b3924027ab7f357fab . +_:ff3ad289ed1e44b3924027ab7f357fab _:2b324b43f968b3f887f5c518136f6ef4 . +_:ff3ad289ed1e44b3924027ab7f357fab "A ChilledBeam must be associated with the Role-Cooling using the relation hasRole" . +_:ff3ad289ed1e44b3924027ab7f357fab "1"^^ . +_:ff3ad289ed1e44b3924027ab7f357fab "1"^^ . +_:c4b5c77a022e1e7acfa6ebddf5fc9b1 . +_:c4b5c77a022e1e7acfa6ebddf5fc9b1 . +_:f615cfd3983bb68d815e7786423b3f72 _:d0437a2a792f386ee9b6a354f0cae9de . +_:2f413619bb5e1ddc4762c5fe54b9158 . +_:2f413619bb5e1ddc4762c5fe54b9158 "A Pump shall have at least one outlet using the medium Water, Oil or Refrigerant." . +_:2f413619bb5e1ddc4762c5fe54b9158 "A Pump shall have at least one outlet using the medium Water, Oil or Refrigerant." . +_:2f413619bb5e1ddc4762c5fe54b9158 _:4a62341ee641b11a8c4f139d912289a0 . +_:9799518702dcf5dbfeaf60f434848a42 . +_:9799518702dcf5dbfeaf60f434848a42 . +_:9799518702dcf5dbfeaf60f434848a42 "A Numerical-Voltage must have a Quantity Kind of Voltage" . +_:2c93adab8312e21fe0673f111f13c724 . +_:2c93adab8312e21fe0673f111f13c724 _:15e54beab70574778e52e8706f8066d9 . +_:96a3ca395015cf4b21b35e2764010a11 . +_:96a3ca395015cf4b21b35e2764010a11 . +_:96a3ca395015cf4b21b35e2764010a11 "A Sensor must be associated with exactly 1 of Connectable, Connection, or ConnectionPoint using the relation hasObservationLocation." . +_:96a3ca395015cf4b21b35e2764010a11 "1"^^ . +_:96a3ca395015cf4b21b35e2764010a11 "1"^^ . +_:3c86e61ef03ace1cbddfba43c0126d9c _:22863055bb6ea4c02d4f5acbb485e8c8 . +_:3c86e61ef03ace1cbddfba43c0126d9c _:406775bde1ee60f147fa1796a81ca46 . +_:2d64af558958f03e8186306ca1fe9e2a _:d1ef7b42cca02f81978c4ece6646de8 . +_:c95bd65215e4f928ae9f64cdc28c0859 . +_:c95bd65215e4f928ae9f64cdc28c0859 . +_:c95bd65215e4f928ae9f64cdc28c0859 "If the relation hasRole is present it must associate the Equipment with a EnumerationKind-Role." . +_:e82c3066043810296918ff783ece4dab . +_:e82c3066043810296918ff783ece4dab _:66ddde6175277f698f49b3651ead3539 . +_:e82c3066043810296918ff783ece4dab "A Fan shall have at least one outlet using the medium Air." . +_:e82c3066043810296918ff783ece4dab "1"^^ . +_:e82c3066043810296918ff783ece4dab "1"^^ . +_:7432046153f89dcfc8e0a5ab047e9a5 _:5baf2ba5ab97c565dfd971d8f0d25d1 . +_:7432046153f89dcfc8e0a5ab047e9a5 _:d7944c84c2f7eacb65982fe8f76adb0 . +_:2ff289a7236f40b979caa174c1385867 . +_:2ff289a7236f40b979caa174c1385867 _:8d866d483bbfce590b26bfc7234a9bf1 . +_:2ff289a7236f40b979caa174c1385867 "A CoolingTower shall have at least one inlet using the medium Water." . +_:2ff289a7236f40b979caa174c1385867 "1"^^ . +_:2ff289a7236f40b979caa174c1385867 "1"^^ . +_:5a9a7dc845aadb26061d0b0f0d2b1059 _:b32dff744d5f86294edc06836f4b72e1 . +_:77067067615d9e709317f18bb402d021 . +_:77067067615d9e709317f18bb402d021 _:221008f9b49bfd16dd4d1425a5ff7a1e . +_:46fa56f66107af8a46f162f3f852840e . +_:46fa56f66107af8a46f162f3f852840e _:5a766cc8ee89fdabeceed2714a8534b3 . +_:c184ba3ff668a0f15d9c378c95b1d33 . +_:c184ba3ff668a0f15d9c378c95b1d33 . +_:c184ba3ff668a0f15d9c378c95b1d33 "If the relation connectedFrom is present it must associate the Connectable with a Connectable." . +_:221008f9b49bfd16dd4d1425a5ff7a1e _:3f00d64f1ce1823bcc6ab86716f2f1d0 . +_:297ae959e6f1fd67be6f2cd69c71eb38 . +_:297ae959e6f1fd67be6f2cd69c71eb38 . +_:297ae959e6f1fd67be6f2cd69c71eb38 "If the relation connectsAt is present it must associate the Connection with a ConnectionPoint." . +_:2e2b461b88062b1edb991a241c132d31 _:1fede9e470b89e3ebf0534c63a133f93 . +_:6be1b3d13402ef027b2dfae12a00d4fb . +_:6be1b3d13402ef027b2dfae12a00d4fb _:920b7adfe90bf25c7918b7efd612541 . +_:6be1b3d13402ef027b2dfae12a00d4fb "A Coil shall have at least one outlet using the medium Air." . +_:6be1b3d13402ef027b2dfae12a00d4fb "1"^^ . +_:6be1b3d13402ef027b2dfae12a00d4fb "1"^^ . +_:d6fded8c5ce9e53fde5c9b1198f4e30c _:b7f26381783b809028f7d993d0909ec . +_:2b7af2df6fe6800238363b6b8949342b _:198fb87dfd7cc9b9dbecfba86c857f06 . +_:bf03f822d9618cc2561f96fd68963092 . +_:bf03f822d9618cc2561f96fd68963092 _:b19c54017ec3cc6e8afc3c518579da40 . +_:bf03f822d9618cc2561f96fd68963092 "One of the constituents of a Water-GlycolSolution must be Medium-Water." . +_:bf03f822d9618cc2561f96fd68963092 "1"^^ . +_:dfa3b0e3830ddefcb491b2d7cdac9eb . +_:dfa3b0e3830ddefcb491b2d7cdac9eb "A Generator must be associated with at least one ConnectionPoint using the relation hasConnectionPoint." . +_:dfa3b0e3830ddefcb491b2d7cdac9eb "1"^^ . +_:197eab5f05c10e413dbca46892d1ab55 . +_:197eab5f05c10e413dbca46892d1ab55 . +_:a5c5eed038b52e57ef355abdc64d430e . +_:a5c5eed038b52e57ef355abdc64d430e _:814850207be73f30bf87363ee773ad51 . +_:d69df34daaae75473a27d0147b398250 _:2e6eaeceb84feca056596416246b178b . +_:12c7b3d01fedb258cd1004fab20d7214 . +_:12c7b3d01fedb258cd1004fab20d7214 . +_:da0ff443374babf86c84fe5277370923 _:6e14243b479f73d8bf2c5dbb3432d18b . +_:da0ff443374babf86c84fe5277370923 _:3e84c32cc8d9c4c5b4d3734ceb95c07a . +_:e12925c55579ef2e80a4f393624214a6 . +_:e12925c55579ef2e80a4f393624214a6 _:fca3ee78a59606175a5f5c58dc814224 . +_:e12925c55579ef2e80a4f393624214a6 "Does this need to allow bidirectional connection points?" . +_:e12925c55579ef2e80a4f393624214a6 "A Damper shall have at least one inlet using the medium Air." . +_:e12925c55579ef2e80a4f393624214a6 "1"^^ . +_:e12925c55579ef2e80a4f393624214a6 "1"^^ . +_:920b7adfe90bf25c7918b7efd612541 . +_:920b7adfe90bf25c7918b7efd612541 _:2682b861a152094e936eb1f5561b55 . +_:1fede9e470b89e3ebf0534c63a133f93 . +_:1fede9e470b89e3ebf0534c63a133f93 . +_:252cc98a22db34128df832a79414e15c . +_:252cc98a22db34128df832a79414e15c . +_:2ffebd6c5239e8a2343b663ff752cb8a . +_:2ffebd6c5239e8a2343b663ff752cb8a . +_:e17a9c0100ba71a41fe04f89b8d305cf . +_:e17a9c0100ba71a41fe04f89b8d305cf . +_:e17a9c0100ba71a41fe04f89b8d305cf "A DifferentialSensor must be associated with exactly 1 of Connectable, Connection, or ConnectionPoint using the relation hasObservationLocationHigh." . +_:e17a9c0100ba71a41fe04f89b8d305cf "1"^^ . +_:e17a9c0100ba71a41fe04f89b8d305cf "1"^^ . +_:5bcb35f83726ddaedfa64c093d443cde . +_:5bcb35f83726ddaedfa64c093d443cde "s223: A DomainSpace must be associated with exactly one EnumerationKind-Domain using the relation hasDomain." . +_:5bcb35f83726ddaedfa64c093d443cde . +_:5bcb35f83726ddaedfa64c093d443cde "A DomainSpace must be associated with exactly one EnumerationKind-Domain using the relation hasDomain." . +_:5bcb35f83726ddaedfa64c093d443cde "1"^^ . +_:5bcb35f83726ddaedfa64c093d443cde "1"^^ . +_:edcb7c59d4b8d83d1aeafbb941403398 . +_:edcb7c59d4b8d83d1aeafbb941403398 _:2338c23bfe24ce6479a6f5e8d16dbb30 . +_:edcb7c59d4b8d83d1aeafbb941403398 "A Compressor shall have at least one outlet." . +_:edcb7c59d4b8d83d1aeafbb941403398 "1"^^ . +_:edcb7c59d4b8d83d1aeafbb941403398 "1"^^ . +_:dddd9aa44f14625f247d6fcb8d41a69f . +_:dddd9aa44f14625f247d6fcb8d41a69f . +_:dddd9aa44f14625f247d6fcb8d41a69f "If the relation hasExternalReference is present it must associate the Property with an ExternalReference." . +_:c4214af0abbb5beca9379d5d01821698 . +_:c4214af0abbb5beca9379d5d01821698 _:b732fe1b929244df82a44e5cc4eff80e . +_:f821023c0475f46618d7712ab9f2d0bc . +_:f821023c0475f46618d7712ab9f2d0bc . +_:58c651d63fe7c32bcd9db4bac457f4c0 _:5d167efefa366f35fceed8da46770a8 . +_:ba444d29daeef1bca023979960a4c969 . +_:ba444d29daeef1bca023979960a4c969 . +_:65607bc361b8adebaef61f46dc5601f6 . +_:65607bc361b8adebaef61f46dc5601f6 _:d990352c73865e62b736b09bcd14eb9a . +_:2ae2b20100f422f7e964a96285a78bb7 . +_:2ae2b20100f422f7e964a96285a78bb7 _:4ca02e8f56b5e92d0e11e2ac39202b8d . +_:2ae2b20100f422f7e964a96285a78bb7 "A HeatPump shall have at least one outlet using the medium Air." . +_:2ae2b20100f422f7e964a96285a78bb7 "1"^^ . +_:2ae2b20100f422f7e964a96285a78bb7 "1"^^ . +_:814850207be73f30bf87363ee773ad51 . +_:27102dcaae5d96598105e82b70815b46 . +_:27102dcaae5d96598105e82b70815b46 _:f783af3c66dc1d73596845c13c43e886 . +_:27102dcaae5d96598105e82b70815b46 "A Boiler shall have at least one inlet using the medium Water." . +_:27102dcaae5d96598105e82b70815b46 "1"^^ . +_:27102dcaae5d96598105e82b70815b46 "1"^^ . +_:a17ab4009e12878182c8631defba1119 _:5a6e05708e73741a85af8142121dadf1 . +_:a0ef80cec8e2465264ef4d1da0dcc96e . +_:a0ef80cec8e2465264ef4d1da0dcc96e _:e6c0d3cf88a3a64464b79f3cdbe5d740 . +_:e2ffed26cca3d36ea50fe6201cd8c163 . +_:e2ffed26cca3d36ea50fe6201cd8c163 . +_:e2ffed26cca3d36ea50fe6201cd8c163 "A DifferentialSensor must be associated with exactly 1 of Connectable, Connection, or ConnectionPoint using the relation hasObservationLocationHigh." . +_:e2ffed26cca3d36ea50fe6201cd8c163 "1"^^ . +_:e2ffed26cca3d36ea50fe6201cd8c163 "1"^^ . +_:782e44e2f0542c955b72e4bae93b4650 . +_:782e44e2f0542c955b72e4bae93b4650 . +_:782e44e2f0542c955b72e4bae93b4650 "If the relation ofSubstance is present it must associate the ParticulateSensor with a Substance-Particulate." . +_:a89097597f06c21439871a6f70df432d . +_:a89097597f06c21439871a6f70df432d . +_:faf83c9e65765582e57bcf9221c5b426 . +_:faf83c9e65765582e57bcf9221c5b426 . +_:faf83c9e65765582e57bcf9221c5b426 "If the relation hasPhysicalLocation is present it must associate the Equipment with a PhysicalSpace." . +_:8745e4b0372e5cc028c6024dfa19a16e . +_:8745e4b0372e5cc028c6024dfa19a16e "s223: A Property can be associated with at most one EnumerationKind-Substance using the relation ofSubstance." . +_:8745e4b0372e5cc028c6024dfa19a16e . +_:8745e4b0372e5cc028c6024dfa19a16e "A Property can be associated with at most one EnumerationKind-Substance using the relation ofSubstance." . +_:8745e4b0372e5cc028c6024dfa19a16e "1"^^ . +_:97360db3691af175b659a31b4a0e85c3 . +_:97360db3691af175b659a31b4a0e85c3 _:64cc609da9e0520d3d83e5e33bd700a5 . +_:8b9e613340cab2a7282079a2e20f8652 _:a165d9ff93358a8dfa5059f4f5f5ae93 . +_:8b9e613340cab2a7282079a2e20f8652 _:3093fac8bca5ce4a3a02a2ad8cc9143a . +_:679307a4b6f5178c3bf4879c5e300c80 . +_:679307a4b6f5178c3bf4879c5e300c80 _:7a5a77390394b6392fa07983e2fc2cd5 . +_:687223cd00d53160697fd0dc639dab72 . +_:687223cd00d53160697fd0dc639dab72 . +_:687223cd00d53160697fd0dc639dab72 "An Actuator must be associated with at least one ActuatableProperty using the relation actuatedByProperty." . +_:687223cd00d53160697fd0dc639dab72 "1"^^ . +_:b23fc45068a73f424d43a686acebc "qudt" . +_:b23fc45068a73f424d43a686acebc "http://qudt.org/schema/qudt/"^^ . +_:48583ebe8481b17bdc757c8d085ad412 _:b9142f83756c17e4a42f67d457c7abf1 . +_:db41305265e9e477ecde7deedf1f5773 . +_:db41305265e9e477ecde7deedf1f5773 . +_:a60fc713d7026579a20ada5031a727a8 . +_:a60fc713d7026579a20ada5031a727a8 _:305e636661c7b6b84c7f06ccd201ac98 . +_:a60fc713d7026579a20ada5031a727a8 "An ElectricBreaker shall have at least one outlet using the medium Electricity." . +_:a60fc713d7026579a20ada5031a727a8 "1"^^ . +_:a60fc713d7026579a20ada5031a727a8 "1"^^ . +_:fcb7d3116df6bd1302e0ae2aab11a003 . +_:fcb7d3116df6bd1302e0ae2aab11a003 _:eeb9808d0013f248f132c5ee764c2efc . +_:64cc609da9e0520d3d83e5e33bd700a5 _:d1c59a4fa40d3f0cb093b1d173c3a91a . +_:eeb9808d0013f248f132c5ee764c2efc _:4bce6ab433630c7ded5ca989ff6ed3f7 . +_:a7d9430efd13a713cfa3f04957db368a . +_:a7d9430efd13a713cfa3f04957db368a . +_:b4791d5544102ab47bc74763fb8f1b3b . +_:b4791d5544102ab47bc74763fb8f1b3b . +_:41c88ec2cf6e8bd578a710dd80c3ddcb . +_:41c88ec2cf6e8bd578a710dd80c3ddcb _:c4f550b6b8f13455f3e0bce84222820c . +_:41c88ec2cf6e8bd578a710dd80c3ddcb "A Chiller shall have at least one outlet using the medium Water." . +_:41c88ec2cf6e8bd578a710dd80c3ddcb "1"^^ . +_:41c88ec2cf6e8bd578a710dd80c3ddcb "1"^^ . +_:16c4dc01f6bca255b7d92234c12e447 . +_:16c4dc01f6bca255b7d92234c12e447 . +_:8499b286735736c879329fc2b181e2f3 "true"^^ . +_:8499b286735736c879329fc2b181e2f3 "s223: A ConnectionPoint must be associated with at most one Connection using the cnx relation" . +_:8499b286735736c879329fc2b181e2f3 . +_:8499b286735736c879329fc2b181e2f3 _:37c2b264e5606e0102e078224eff02a3 . +_:8499b286735736c879329fc2b181e2f3 "A ConnectionPoint must be associated with at most one Connection using the cnx relation" . +_:8499b286735736c879329fc2b181e2f3 "1"^^ . +_:d6e17fbe7f08173e50b901aeefe80ecd . +_:d6e17fbe7f08173e50b901aeefe80ecd "s223: A ConnectionPoint can be associated with at most one other ConnectionPoint using the relation mapsTo" . +_:d6e17fbe7f08173e50b901aeefe80ecd . +_:d6e17fbe7f08173e50b901aeefe80ecd "A ConnectionPoint can be associated with at most one other ConnectionPoint using the relation mapsTo" . +_:d6e17fbe7f08173e50b901aeefe80ecd "1"^^ . +_:5d167efefa366f35fceed8da46770a8 . +_:5d167efefa366f35fceed8da46770a8 . +_:a724e09a67cd607cc245c66e1932427f . +_:a724e09a67cd607cc245c66e1932427f _:de0d6f9e9d19d49a4842024d6e81b3a5 . +_:f4840bae71c5c644e589750b9c71a280 . +_:42db59df61615cd48d91e2fa6c47994e . +_:42db59df61615cd48d91e2fa6c47994e _:4dcee9feba87350a73797b76698783af . +_:e7f846f90db5b85d96b780ebd1705b97 . +_:e7f846f90db5b85d96b780ebd1705b97 _:84f62142f084f5b3878a6e7025c483e . +_:25ca38abc2f19df3627a7b7bd4a91f70 . +_:25ca38abc2f19df3627a7b7bd4a91f70 "s223: A Concept must be associated with at least one label using the relation label." . +_:25ca38abc2f19df3627a7b7bd4a91f70 . +_:25ca38abc2f19df3627a7b7bd4a91f70 "A Concept must be associated with at least one label using the relation label." . +_:25ca38abc2f19df3627a7b7bd4a91f70 "1"^^ . +_:e562bad29e14c68cbfd35696f6d99d13 _:7e84ec88f7021f496b6904090155eb47 . +_:e562bad29e14c68cbfd35696f6d99d13 _:9877b89127935c910b355862d14bc93d . +_:776ce7e710880528030c442aac307913 . +_:776ce7e710880528030c442aac307913 _:a63d0e545f4641fd0e26885d59bf7231 . +_:776ce7e710880528030c442aac307913 "A PowerOverEthernetSwitch shall have at least one inlet using the medium Electricity." . +_:776ce7e710880528030c442aac307913 "1"^^ . +_:bb9d76456086a4a0ca491564a237b887 . +_:bb9d76456086a4a0ca491564a237b887 . +_:bb9d76456086a4a0ca491564a237b887 "A Numerical-Frequency must have a Quantity Kind of Frequency" . +_:95302b2acdbf4eaff70d310aeaf97f19 . +_:95302b2acdbf4eaff70d310aeaf97f19 . +_:95302b2acdbf4eaff70d310aeaf97f19 "A QuantifiableProperty can be associated with a decimal value using the relation hasValue." . +_:bd0ca9e5db40b6ac7481af1a3f60043d _:89321268a76ac93b0401d3e44be0b9ae . +_:23c75ab36b68de61b07a7dca7661253d . +_:23c75ab36b68de61b07a7dca7661253d _:2c93adab8312e21fe0673f111f13c724 . +_:23c75ab36b68de61b07a7dca7661253d "A FanCoilUnit shall have at least one outlet using the medium Air." . +_:23c75ab36b68de61b07a7dca7661253d "1"^^ . +_:23c75ab36b68de61b07a7dca7661253d "1"^^ . +_:ec58719d75d64b6f0e7f1e10f0e7c2 . +_:3799d44e4797c05278a9fc260bfd4a55 . +_:3799d44e4797c05278a9fc260bfd4a55 _:a96233b73912c3dd39956f9ec3ce70cb . +_:79d2c172639ea183e9c175465e679f12 _:203ca0c2a79b6ce7bb5f3e0be5c18e07 . +_:3093fac8bca5ce4a3a02a2ad8cc9143a . +_:d1c59a4fa40d3f0cb093b1d173c3a91a . +_:d1c59a4fa40d3f0cb093b1d173c3a91a . +_:3c12b196f6b59823f073353b14a59e8f . +_:3c12b196f6b59823f073353b14a59e8f _:ed2f27439990714eae6c5804a3dc8c . +_:3c12b196f6b59823f073353b14a59e8f "One of the constituents of PoE must be Ethernet." . +_:3c12b196f6b59823f073353b14a59e8f "1"^^ . +_:288edac29e8c6a717bb0e0b545dd597b . +_:288edac29e8c6a717bb0e0b545dd597b . +_:956abe7694c40cbadf3866ccc6008ec4 . +_:956abe7694c40cbadf3866ccc6008ec4 . +_:956abe7694c40cbadf3866ccc6008ec4 "If the relation hasOutput is present it must associate a Function with a Property." . +_:c8dc541a26fe365ccf3161c7b994780d _:c95889bc4445eb27d9fd83524e3ecb85 . +_:4a62341ee641b11a8c4f139d912289a0 _:fe7462fe1e3c83b43da1fd809e4ed55f . +_:4a62341ee641b11a8c4f139d912289a0 _:33db8cf03fb49a250e5895a1b5088205 . +_:fddc6a19a56dabbeba79200e7d22c070 . +_:fddc6a19a56dabbeba79200e7d22c070 . +_:d0437a2a792f386ee9b6a354f0cae9de . +_:d0437a2a792f386ee9b6a354f0cae9de . +_:1f6bda95f292f112ba7c4bf4c985a40d . +_:1f6bda95f292f112ba7c4bf4c985a40d . +_:1f6bda95f292f112ba7c4bf4c985a40d "If the relation encloses is present it must associate the PhysicalSpace with a DomainSpace." . +_:a9c6455a615bb66c955580e954327e5 . +_:a9c6455a615bb66c955580e954327e5 _:2566147f4c5bd103ce3af497317b75ea . +_:a9c6455a615bb66c955580e954327e5 "A ChilledBeam shall have at least one inlet using the medium Water." . +_:a9c6455a615bb66c955580e954327e5 "1"^^ . +_:a9c6455a615bb66c955580e954327e5 "1"^^ . +_:f783af3c66dc1d73596845c13c43e886 . +_:f783af3c66dc1d73596845c13c43e886 _:ddec5155993615b1f6e3968cb860cf0d . +_:888a9ee0ada7fbffddddda0e9ac8db91 . +_:888a9ee0ada7fbffddddda0e9ac8db91 _:29a3d60b4039dd939173c3f9ff92f409 . +_:888a9ee0ada7fbffddddda0e9ac8db91 "A TwoWayValve shall have at least one inlet." . +_:888a9ee0ada7fbffddddda0e9ac8db91 "1"^^ . +_:888a9ee0ada7fbffddddda0e9ac8db91 "1"^^ . +_:df4bc6486690fb4aedc123459de77a94 _:26ecf1a740ad3916f3d6e724dc5f504b . +_:df4bc6486690fb4aedc123459de77a94 . +_:a920d56f1aa871a43d3257dcfb145e6b . +_:ccd8b6720490240c84be9d5cde61efa7 _:32b6feff9dbe82491197d4acd5f0d418 . +_:ccd8b6720490240c84be9d5cde61efa7 _:483b440fda3c68b321033e1e44c86eb2 . +_:ef6d9401760da680fe75f1c933458565 . +_:ef6d9401760da680fe75f1c933458565 _:ee4ebe3316d652b0bf6b99b1f171c094 . +_:5a6e05708e73741a85af8142121dadf1 . +_:5a6e05708e73741a85af8142121dadf1 . +_:6ae15f291b925142ba177942af03803e . +_:6ae15f291b925142ba177942af03803e . +_:6ae15f291b925142ba177942af03803e "If the relation actuatedByProperty is present it must associate the Equipment with a ActuatableProperty." . +_:43434f76d97d9380816ad548adf498b7 _:a5c5eed038b52e57ef355abdc64d430e . +_:43434f76d97d9380816ad548adf498b7 _:917e51c837f1e479d76a4079541b65d4 . +_:62fd1f774b4dfac01ba6a8e1334941cd . +_:62fd1f774b4dfac01ba6a8e1334941cd . +_:49ac683ec5d8215ef862106ef137e1fe . +_:49ac683ec5d8215ef862106ef137e1fe _:acd4ad17ae94230b43e9d4a4bbd18f87 . +_:49ac683ec5d8215ef862106ef137e1fe "A FanCoilUnit shall have at least one inlet using the medium Air." . +_:49ac683ec5d8215ef862106ef137e1fe "1"^^ . +_:49ac683ec5d8215ef862106ef137e1fe "1"^^ . +_:58891e0b0fa894b80ccb390305b4147b . +_:58891e0b0fa894b80ccb390305b4147b _:f2e2312a8222db1335ed62684fe7d070 . +_:5a80daf25f013cb7c3b488e985256d6 . +_:ddec5155993615b1f6e3968cb860cf0d _:802d7054559f8941ffe53631c569755 . +_:8d4cbd571611ce5fc68f858fd8625329 . +_:8d4cbd571611ce5fc68f858fd8625329 _:679307a4b6f5178c3bf4879c5e300c80 . +_:8d4cbd571611ce5fc68f858fd8625329 "A Window shall have at least one inlet using the medium Light." . +_:8d4cbd571611ce5fc68f858fd8625329 "1"^^ . +_:8d4cbd571611ce5fc68f858fd8625329 "1"^^ . +_:b32dff744d5f86294edc06836f4b72e1 . +_:b32dff744d5f86294edc06836f4b72e1 . +_:cf813a89a634ce5b6f7e3141ea94fa9 "quantitykind" . +_:cf813a89a634ce5b6f7e3141ea94fa9 "http://qudt.org/vocab/quantitykind/"^^ . +_:ad669fa2e1a8422424d3c754efcd0e9f . +_:ad669fa2e1a8422424d3c754efcd0e9f "A ThreeWayValve must have at least three ConnectionPoints using the relation hasConnectionPoint." . +_:ad669fa2e1a8422424d3c754efcd0e9f "3"^^ . +_:a523440f57370b4f362942074714c1fe . +_:a523440f57370b4f362942074714c1fe _:b28378600bd46643d04d2f864df09328 . +_:a523440f57370b4f362942074714c1fe "A ChilledBeam shall have at least one outlet using the medium Water." . +_:a523440f57370b4f362942074714c1fe "1"^^ . +_:a523440f57370b4f362942074714c1fe "1"^^ . +_:4ad35ae61e2024c8dd79fa4f0fc6781d . +_:4ad35ae61e2024c8dd79fa4f0fc6781d . +_:4ad35ae61e2024c8dd79fa4f0fc6781d "A DifferentialSensor must be associated with exactly 1 of Connectable, Connection, or ConnectionPoint using the relation hasObservationLocationLow." . +_:4ad35ae61e2024c8dd79fa4f0fc6781d "1"^^ . +_:4ad35ae61e2024c8dd79fa4f0fc6781d "1"^^ . +_:c6ea4a8f89ae6e117712b5ad34fbae24 _:88b8f718c634fe9b69eb3d1e3ba4cd2 . +_:66ddde6175277f698f49b3651ead3539 . +_:66ddde6175277f698f49b3651ead3539 _:5adac3eafc9b6113b17a15ac6f9ddddb . +_:483b440fda3c68b321033e1e44c86eb2 . +_:483b440fda3c68b321033e1e44c86eb2 . +_:483b440fda3c68b321033e1e44c86eb2 "The quantity kind of the constituent must be VolumeFraction." . +_:fa8db41929dc52d5ef03d91ecf8c705b . +_:fa8db41929dc52d5ef03d91ecf8c705b _:7066e24d05741dc4013b7f5f6c929bda . +_:fa8db41929dc52d5ef03d91ecf8c705b "A Filter shall have at least one inlet ConnectionPoint." . +_:fa8db41929dc52d5ef03d91ecf8c705b "1"^^ . +_:fa8db41929dc52d5ef03d91ecf8c705b "1"^^ . +_:1f2704e560ddcc85de8523b41bab6540 . +_:1f2704e560ddcc85de8523b41bab6540 _:219c5e28c16d20a292a9f2a85fb21d36 . +_:f8f382c3f67e4995ce1b8535741ce96d . +_:f8f382c3f67e4995ce1b8535741ce96d "If the relation hasElectricalPhase is present it must associate the ElectricWire with an ElectricalPhaseIdentifier or ElectricalVoltagePhases." . +_:f8f382c3f67e4995ce1b8535741ce96d _:43434f76d97d9380816ad548adf498b7 . +_:ed2f27439990714eae6c5804a3dc8c . +_:ed2f27439990714eae6c5804a3dc8c _:2d64af558958f03e8186306ca1fe9e2a . +_:31ea85fec81383339c6a8bc32b394c38 . +_:31ea85fec81383339c6a8bc32b394c38 . +_:acd4ad17ae94230b43e9d4a4bbd18f87 . +_:acd4ad17ae94230b43e9d4a4bbd18f87 _:7a05d78d3854318d55a6af02e5d75362 . +_:ee627d763ba6d47412a056eda1597a6f . +_:ee627d763ba6d47412a056eda1597a6f . +_:ee627d763ba6d47412a056eda1597a6f "If the relation executes is present it must associate the Controller with a Function." . +_:2755b05cc3f99ef4fa0965334d7d8793 . +_:fee9f9bc11856aa4548096c0dd4fa271 . +_:fee9f9bc11856aa4548096c0dd4fa271 _:129898ffa8193b87bca9d8375bf5c2b . +_:fee9f9bc11856aa4548096c0dd4fa271 "A Pump shall have at least one inlet using the medium Water, Oil or Refrigerant." . +_:fee9f9bc11856aa4548096c0dd4fa271 "1"^^ . +_:fee9f9bc11856aa4548096c0dd4fa271 "1"^^ . +_:99c3481fa82c191bc6e5050664fcd759 . +_:99c3481fa82c191bc6e5050664fcd759 . +_:99c3481fa82c191bc6e5050664fcd759 "An AC-Numerical-LineLineVoltage must have a voltage" . +_:99c3481fa82c191bc6e5050664fcd759 "1"^^ . +_:72c1f39a0eddd170f1eada49e1aa272d . +_:72c1f39a0eddd170f1eada49e1aa272d _:e9ad08ac8292a46744ae8131053ea707 . +_:26a31ddfcb00ef4aaf051012e960fe45 . +_:26a31ddfcb00ef4aaf051012e960fe45 _:2f413619bb5e1ddc4762c5fe54b9158 . +_:e0afb8176b645e0787919040a91259c6 _:4c1331fe6c270cdc19bb3d864fef20f0 . +_:13e9301f028eb951dbc389d4d76ba1ec . +_:13e9301f028eb951dbc389d4d76ba1ec . +_:13e9301f028eb951dbc389d4d76ba1ec "A Sensor must be associated with exactly 1 of Connectable, Connection, or ConnectionPoint using the relation hasObservationLocation." . +_:13e9301f028eb951dbc389d4d76ba1ec "1"^^ . +_:13e9301f028eb951dbc389d4d76ba1ec "1"^^ . +_:f2e019faf42fcdf80c919249127c95a6 . +_:f2e019faf42fcdf80c919249127c95a6 . +_:f2e019faf42fcdf80c919249127c95a6 "If the relation executes is present it must associate the Equipment with a Function." . +_:cdcf947789b0233367ecaa4480312e61 _:97db336542db167405cd5153146eee1d . +_:6917cf95fc3df4640d55f0d6d29b1d42 _:e2ffed26cca3d36ea50fe6201cd8c163 . +_:72aa6723f092566666a020c1f74b9113 _:d296b3209601f7994d769d34bfa76138 . +_:4dcee9feba87350a73797b76698783af _:a89097597f06c21439871a6f70df432d . +_:b7f26381783b809028f7d993d0909ec . +_:b7f26381783b809028f7d993d0909ec . +_:cb222ed8a00712ef05ad278dadccae29 . +_:cb222ed8a00712ef05ad278dadccae29 . +_:8d866d483bbfce590b26bfc7234a9bf1 . +_:8d866d483bbfce590b26bfc7234a9bf1 _:d3753dabf4c1499451a518ba07d66518 . +_:d3753dabf4c1499451a518ba07d66518 _:f2d16fa6b994cf328ec2c68b3ba62419 . +_:59ce820ed314c86968b68dcdf29686a . +_:59ce820ed314c86968b68dcdf29686a "s223: If the relation hasThermodynamicPhase is present it must associate the Connection with at most one EnumerationKind-Phase." . +_:59ce820ed314c86968b68dcdf29686a . +_:59ce820ed314c86968b68dcdf29686a "If the relation hasThermodynamicPhase is present it must associate the Connection with at most one EnumerationKind-Phase." . +_:59ce820ed314c86968b68dcdf29686a "1"^^ . +_:a6ecfcced590ee0eb66e7ad265774eb1 . +_:a6ecfcced590ee0eb66e7ad265774eb1 _:ae8b3960252883f6ee134769ec9bef44 . +_:a6ecfcced590ee0eb66e7ad265774eb1 "One of the constituents of PoE must be DC electrical power." . +_:a6ecfcced590ee0eb66e7ad265774eb1 "1"^^ . +_:d7944c84c2f7eacb65982fe8f76adb0 . +_:2af4a987609a65fb221c0b0f30739534 . +_:2af4a987609a65fb221c0b0f30739534 _:1543c07273c93fc67729bc52beeae6bb . +_:2af4a987609a65fb221c0b0f30739534 "A PowerOverEthernetSwitch shall have at least one outlet using the medium DC-48V." . +_:2af4a987609a65fb221c0b0f30739534 "1"^^ . +_:c1cc1d3db370ba27cf55f71c6fcaf3ed . +_:6e14243b479f73d8bf2c5dbb3432d18b . +_:6e14243b479f73d8bf2c5dbb3432d18b _:4375abb21156f3ec40568e9f5c6200a1 . +_:24eeba9675ec2715e70a5acc9e82f618 . +_:24eeba9675ec2715e70a5acc9e82f618 "s223: A ConnectionPoint must be associated with exactly one Substance-Medium using the relation hasMedium." . +_:24eeba9675ec2715e70a5acc9e82f618 . +_:24eeba9675ec2715e70a5acc9e82f618 "A ConnectionPoint must be associated with exactly one Substance-Medium using the relation hasMedium." . +_:24eeba9675ec2715e70a5acc9e82f618 "ConnectionPoint medium" . +_:24eeba9675ec2715e70a5acc9e82f618 "1"^^ . +_:24eeba9675ec2715e70a5acc9e82f618 "1"^^ . +_:51f4f236abf807e9798ec9292adfe522 . +_:51f4f236abf807e9798ec9292adfe522 . +_:51f4f236abf807e9798ec9292adfe522 . +_:51f4f236abf807e9798ec9292adfe522 "An EnumerationKind-Numerical must be associated with at least one Unit using the relation hasUnit." . +_:51f4f236abf807e9798ec9292adfe522 "1"^^ . +_:4bce6ab433630c7ded5ca989ff6ed3f7 . +_:4bce6ab433630c7ded5ca989ff6ed3f7 . +_:4bce6ab433630c7ded5ca989ff6ed3f7 "A DifferentialSensor must be associated with exactly 1 of Connectable, Connection, or ConnectionPoint using the relation hasObservationLocationLow." . +_:4bce6ab433630c7ded5ca989ff6ed3f7 "1"^^ . +_:4bce6ab433630c7ded5ca989ff6ed3f7 "1"^^ . +_:a463dbde6f441f265243bc4ce7ba8ca3 _:119044564bb04f492f7c3eae52cf79af . +_:a463dbde6f441f265243bc4ce7ba8ca3 _:f469177d63d0be8315ea7380178c1f7b . +_:30ccced4086eb369393fde9e47890b97 . +_:30ccced4086eb369393fde9e47890b97 _:7254df18c0ac28025b2c14f840d7bd4 . +_:30ccced4086eb369393fde9e47890b97 "A Differential Sensor must be defined in terms of the QuantityKind that is being measured." . +_:30ccced4086eb369393fde9e47890b97 "1"^^ . +_:362b6a303f1180c08b0124f7ef9f6b60 _:b5b1f29dd65231264db614415327b112 . +_:bad220b3bb315bf684949169a4616319 . +_:bad220b3bb315bf684949169a4616319 "s223: A Zone must be associated with at least one DomainSpace using the relation hasDomainSpace." . +_:bad220b3bb315bf684949169a4616319 . +_:bad220b3bb315bf684949169a4616319 "A Zone must be associated with at least one DomainSpace using the relation hasDomainSpace." . +_:bad220b3bb315bf684949169a4616319 "1"^^ . +_:ab14a3fae5b0f6558b9746935dccffa9 . +_:ab14a3fae5b0f6558b9746935dccffa9 _:d3fcc33f1747b12bca9ca14e7bdf57c5 . +_:ab14a3fae5b0f6558b9746935dccffa9 "An ElectricTransformer shall have at least one inlet using the medium Electricity." . +_:ab14a3fae5b0f6558b9746935dccffa9 "1"^^ . +_:ab14a3fae5b0f6558b9746935dccffa9 "1"^^ . +_:5b11044d8c0c764475656a2302560024 . +_:fe5bcb89d2d196a84884f55f415db583 . +_:fe5bcb89d2d196a84884f55f415db583 "s223: An ElectricWire must be associated with exactly one Medium-Electricity using the relation hasMedium." . +_:fe5bcb89d2d196a84884f55f415db583 . +_:fe5bcb89d2d196a84884f55f415db583 "An ElectricWire must be associated with exactly one Medium-Electricity using the relation hasMedium." . +_:fe5bcb89d2d196a84884f55f415db583 "1"^^ . +_:fe5bcb89d2d196a84884f55f415db583 "1"^^ . +_:440f6c6edd1488dfc93a88ff6a114e94 . +_:440f6c6edd1488dfc93a88ff6a114e94 . +_:69b0fb1cad311ddd74866bb096e7b56d . +_:69b0fb1cad311ddd74866bb096e7b56d _:97360db3691af175b659a31b4a0e85c3 . +_:69b0fb1cad311ddd74866bb096e7b56d "A Door shall have at least two bidirectional connection points using the medium Air." . +_:69b0fb1cad311ddd74866bb096e7b56d "2"^^ . +_:69b0fb1cad311ddd74866bb096e7b56d "2"^^ . +_:421f967b825e0f8b07e1c59fa3fd9272 _:1b27814b932b91e1e7322f0bd9b25f8 . +_:61d82b7fda6687cc316c9035426c045b . +_:61d82b7fda6687cc316c9035426c045b "s223: A ZoneGroup must be associated with exactly one EnumerationKind-Domain using the relation hasDomain." . +_:61d82b7fda6687cc316c9035426c045b . +_:61d82b7fda6687cc316c9035426c045b "A ZoneGroup must be associated with exactly one EnumerationKind-Domain using the relation hasDomain." . +_:61d82b7fda6687cc316c9035426c045b "1"^^ . +_:61d82b7fda6687cc316c9035426c045b "1"^^ . +_:28bdf94752599f1f309d8c490974181 . +_:28bdf94752599f1f309d8c490974181 _:a920d56f1aa871a43d3257dcfb145e6b . +_:28bdf94752599f1f309d8c490974181 "A Filter shall have at least one outlet." . +_:28bdf94752599f1f309d8c490974181 "1"^^ . +_:28bdf94752599f1f309d8c490974181 "1"^^ . +_:26ecf1a740ad3916f3d6e724dc5f504b . +_:26ecf1a740ad3916f3d6e724dc5f504b . +_:5a766cc8ee89fdabeceed2714a8534b3 _:11c3891175435ad2ec45e9fe12a45c5b . +_:802d7054559f8941ffe53631c569755 . +_:802d7054559f8941ffe53631c569755 . +_:f61f5d19a6227622e709587b13b154bf _:1684ec59400f66c29cca19c63d4ddd44 . +_:f61f5d19a6227622e709587b13b154bf _:3617ec7c7f850ace24ae62771f98c1f9 . +_:4080180b2636f557d12460afcd997aeb . +_:50a32f68d41052e79e5611550b9e622b . +_:50a32f68d41052e79e5611550b9e622b . +_:50a32f68d41052e79e5611550b9e622b "A Generator shall have at least one outlet using the medium Electricity." . +_:50a32f68d41052e79e5611550b9e622b "1"^^ . +_:50a32f68d41052e79e5611550b9e622b _:309dedbd78bb9b9d193c510c10bb469a . +_:305e636661c7b6b84c7f06ccd201ac98 . +_:305e636661c7b6b84c7f06ccd201ac98 _:766b541fa55821a783f3c63e86428bf9 . +_:b732fe1b929244df82a44e5cc4eff80e _:fddc6a19a56dabbeba79200e7d22c070 . +_:2de1b533e3ddfb3904a87944e514b6c9 _:197eab5f05c10e413dbca46892d1ab55 . +_:4ca02e8f56b5e92d0e11e2ac39202b8d . +_:4ca02e8f56b5e92d0e11e2ac39202b8d _:d6fded8c5ce9e53fde5c9b1198f4e30c . +_:9a06fa83d852ed9ce020cea04d84911b _:440f6c6edd1488dfc93a88ff6a114e94 . +_:32aefca0c68e9dcc3cfe2807b444ab74 . +_:32aefca0c68e9dcc3cfe2807b444ab74 . +_:32aefca0c68e9dcc3cfe2807b444ab74 "A Sensor must be associated with exactly 1 of QuantifiableObservableProperty or EnumeratedObservableProperty using the relation observes." . +_:32aefca0c68e9dcc3cfe2807b444ab74 "1"^^ . +_:32aefca0c68e9dcc3cfe2807b444ab74 "1"^^ . +_:42902de475c49b823c68508cabe14349 . +_:42902de475c49b823c68508cabe14349 . +_:422e59539b15fdcd75d985a066854a6d . +_:422e59539b15fdcd75d985a066854a6d _:ba24d74c3fdb56d5ed6dd698fb179562 . +_:a96233b73912c3dd39956f9ec3ce70cb _:9dc0a9c97be700ac1f7bcd220749eea9 . +_:432e06ca6e8d6b058d7f9128591c4366 . +_:432e06ca6e8d6b058d7f9128591c4366 . +_:432e06ca6e8d6b058d7f9128591c4366 "If the relation hasRole is present it must associate the Connection with an EnumerationKind-Role." . +_:b8efa4f4f705f2e84c1caf51207bd84c . +_:b8efa4f4f705f2e84c1caf51207bd84c . +_:b8efa4f4f705f2e84c1caf51207bd84c "If the relation contains is present it must associate the PhysicalSpace with a PhysicalSpace." . +_:7c20ffa07b6ad02f778eed39f002b0f7 _:2bd319fce4652882f67c1f0c1f6608d6 . +_:bc17bec80be7a538d214f5b526ed068 . +_:bc17bec80be7a538d214f5b526ed068 _:4c0348ab36904e46479589a86f9e0c64 . +_:bc17bec80be7a538d214f5b526ed068 "A FanCoilUnit must be associated with at least 1 Coil using the relation contains." . +_:bc17bec80be7a538d214f5b526ed068 "1"^^ . +_:bc17bec80be7a538d214f5b526ed068 "1"^^ . +_:facbc2485a830f5d88e6cb077183c381 . +_:facbc2485a830f5d88e6cb077183c381 "s223: A ConnectionPoint must be associated with exactly one Connectable using the relation isConnectionPointOf." . +_:facbc2485a830f5d88e6cb077183c381 . +_:facbc2485a830f5d88e6cb077183c381 "A ConnectionPoint must be associated with exactly one Connectable using the relation isConnectionPointOf." . +_:facbc2485a830f5d88e6cb077183c381 "ConnectionPointToEquipmentShape" . +_:facbc2485a830f5d88e6cb077183c381 "1"^^ . +_:facbc2485a830f5d88e6cb077183c381 "1"^^ . +_:90e34a75456cb45f8b72d3d36e81c7d2 . +_:90e34a75456cb45f8b72d3d36e81c7d2 . +_:90e34a75456cb45f8b72d3d36e81c7d2 "If the relation hasConstituent is present, it must associate an EnumerationKind-Substance with one or more Properties that identify and characterize those constituents." . +_:89321268a76ac93b0401d3e44be0b9ae . +_:89321268a76ac93b0401d3e44be0b9ae . +_:89321268a76ac93b0401d3e44be0b9ae "One of the constituents of PoE must be DC electrical power." . +_:cdec220def885a96fb042136f7138694 . +_:cdec220def885a96fb042136f7138694 . +_:cdec220def885a96fb042136f7138694 "A Numerical-Voltage must have a unit of Volts" . +_:f2d16fa6b994cf328ec2c68b3ba62419 . +_:f2d16fa6b994cf328ec2c68b3ba62419 . +_:3a0f31c4d3a235394485fa1fe34f1bf8 _:f821023c0475f46618d7712ab9f2d0bc . +_:77ff7c01b56527c965cc2f9135de97be _:22ec97cf643b6108574d2ae5246df358 . +_:34b430d7ff7c0f3bf5aad4ce56fac27e . +_:34b430d7ff7c0f3bf5aad4ce56fac27e _:422e59539b15fdcd75d985a066854a6d . +_:34b430d7ff7c0f3bf5aad4ce56fac27e "A PowerOverEthernetSwitch shall have at least two BidirectionalConnectionPoints using the medium Signal-Ethernet." . +_:34b430d7ff7c0f3bf5aad4ce56fac27e "2"^^ . +_:f3bdccc2913dd3b253841d02a317cc70 . +_:f3bdccc2913dd3b253841d02a317cc70 . +_:33d3c725c2e685d00c51c8e9c4ca3e _:25e261857ae23f79d102443bcb6d9b17 . +_:466de7655987cee55a73e2884aba8e29 . +_:466de7655987cee55a73e2884aba8e29 . +_:466de7655987cee55a73e2884aba8e29 "The quantity kind of the constituent must be VolumeFraction." . +_:de0d6f9e9d19d49a4842024d6e81b3a5 _:2cd5917cf22ca8f12eb56b10d6dcab2f . +_:a165d9ff93358a8dfa5059f4f5f5ae93 . +_:a165d9ff93358a8dfa5059f4f5f5ae93 _:ec58719d75d64b6f0e7f1e10f0e7c2 . +_:98fdca6f66c6305c252efe70af3ecd30 . +_:98fdca6f66c6305c252efe70af3ecd30 . +_:98fdca6f66c6305c252efe70af3ecd30 "A DifferentialSensor must be associated with exactly 1 of Connectable, Connection, or ConnectionPoint using the relation hasObservationLocationHigh." . +_:98fdca6f66c6305c252efe70af3ecd30 "1"^^ . +_:98fdca6f66c6305c252efe70af3ecd30 "1"^^ . +_:5ac071980192450900deac330ce933e9 . +_:5ac071980192450900deac330ce933e9 "s223: A Junction must be associated with exactly one EnumerationKind-Medium using the relation hasMedium." . +_:5ac071980192450900deac330ce933e9 . +_:5ac071980192450900deac330ce933e9 "A Junction must be associated with exactly one EnumerationKind-Medium using the relation hasMedium." . +_:5ac071980192450900deac330ce933e9 "1"^^ . +_:5ac071980192450900deac330ce933e9 "1"^^ . +_:219c5e28c16d20a292a9f2a85fb21d36 _:134d2824c4419ac89ea2165f6ae35ef3 . +_:7c54fb947753c917efc4b06ce9aafcf1 "Unspecified" . +_:7c54fb947753c917efc4b06ce9aafcf1 . +_:7c54fb947753c917efc4b06ce9aafcf1 . +_:7c54fb947753c917efc4b06ce9aafcf1 . +_:7c54fb947753c917efc4b06ce9aafcf1 . +_:9457936fcefe4db1c5d1f28f95e5ebe4 . +_:9457936fcefe4db1c5d1f28f95e5ebe4 "A heat exchanger shall have at least 4 connection points." . +_:9457936fcefe4db1c5d1f28f95e5ebe4 "4"^^ . +_:bc67586b701df3822b6c6efd44b90f46 . +_:bc67586b701df3822b6c6efd44b90f46 "A Pump shall have at least one inlet using the medium Water, Oil or Refrigerant." . +_:bc67586b701df3822b6c6efd44b90f46 "A Pump shall have at least one inlet using the medium Water, Oil or Refrigerant." . +_:bc67586b701df3822b6c6efd44b90f46 _:4e5cdde94039ec9b269867e29fc848a6 . +_:ef2cc4e44b5ebe9e45dd97294a918415 . +_:ef2cc4e44b5ebe9e45dd97294a918415 . +_:3a75deb0bfd118eb82b540d901e24b06 . +_:3a75deb0bfd118eb82b540d901e24b06 . +_:3a75deb0bfd118eb82b540d901e24b06 "If the relation hasConnectionPoint is present it must associate the Connectable with a ConnectionPoint." . +_:3a75deb0bfd118eb82b540d901e24b06 "EquipmentToConnectionPointShape" . +_:2baf90bd33f4cff2ad7eedef7c709feb . +_:2baf90bd33f4cff2ad7eedef7c709feb _:c9e4e4663c82b4060c4d94233734b460 . +_:2baf90bd33f4cff2ad7eedef7c709feb "A FanCoilUnit must at least have the role Role-Heating or Role-Cooling." . +_:2baf90bd33f4cff2ad7eedef7c709feb "1"^^ . +_:2baf90bd33f4cff2ad7eedef7c709feb "1"^^ . +_:ff07f3f3dfc150bfb82905f739b8f148 . +_:ff07f3f3dfc150bfb82905f739b8f148 _:cdcf947789b0233367ecaa4480312e61 . +_:88d9d839119ffb8a63eb25ff4188ae34 . +_:88d9d839119ffb8a63eb25ff4188ae34 . +_:88d9d839119ffb8a63eb25ff4188ae34 "If the relation connectsFrom is present it must associate the Connection with a Connectable." . +_:88d9d839119ffb8a63eb25ff4188ae34 "ConnectionToUpstreamConnectableShape" . +_:eac701aaba858ad151222aa73c3045ae . +_:eac701aaba858ad151222aa73c3045ae _:7b072d57514167d67fe9f9cfadf16e89 . +_:eac701aaba858ad151222aa73c3045ae "A Furnace shall have at least one inlet using the medium Air." . +_:eac701aaba858ad151222aa73c3045ae "1"^^ . +_:eac701aaba858ad151222aa73c3045ae "1"^^ . +_:200f69533a7838a9e5c2a5965e20e147 . +_:200f69533a7838a9e5c2a5965e20e147 . +_:200f69533a7838a9e5c2a5965e20e147 "s223: A Connection must have two or more cnx relations to ConnectionPoints" . +_:200f69533a7838a9e5c2a5965e20e147 . +_:200f69533a7838a9e5c2a5965e20e147 "A Connection must have two or more cnx relations to ConnectionPoints" . +_:200f69533a7838a9e5c2a5965e20e147 "2"^^ . +_:db9653614ef3f0ea08f5e95cf9864534 . +_:db9653614ef3f0ea08f5e95cf9864534 _:51de263df76cc82ba99f94c6e2bd0615 . +_:db9653614ef3f0ea08f5e95cf9864534 "An EthernetSwitch shall have at least one inlet using the medium Electricity." . +_:db9653614ef3f0ea08f5e95cf9864534 "1"^^ . +_:d4c16a91f90b66540807bc03acbf1ec6 . +_:d4c16a91f90b66540807bc03acbf1ec6 _:c23a62c9e2c9c9594543d712bb4fd042 . +_:d4c16a91f90b66540807bc03acbf1ec6 "A ResistanceHeater shall have at least one inlet using the medium Electricity." . +_:d4c16a91f90b66540807bc03acbf1ec6 "1"^^ . +_:d4c16a91f90b66540807bc03acbf1ec6 "1"^^ . +_:70e08e39a71adad65aaa1468988f27b0 . +_:70e08e39a71adad65aaa1468988f27b0 _:a47947f7c508dde3d1bdb57e5e3762a9 . +_:70e08e39a71adad65aaa1468988f27b0 "A Damper shall have at least one outlet using the medium Air." . +_:70e08e39a71adad65aaa1468988f27b0 "1"^^ . +_:70e08e39a71adad65aaa1468988f27b0 "1"^^ . +_:7e84ec88f7021f496b6904090155eb47 . +_:7e84ec88f7021f496b6904090155eb47 _:89981df6ed1f3dfee047766481b4167d . +_:9f9eba976390bc7ea5cf11ef0f724d4d . +_:f2d7ece86a3c3a0a5ca58bf2e0768a86 . +_:f2d7ece86a3c3a0a5ca58bf2e0768a86 _:3799d44e4797c05278a9fc260bfd4a55 . +_:f2d7ece86a3c3a0a5ca58bf2e0768a86 "A SolarThermalCollector shall have at least one inlet using the medium EM-Light." . +_:f2d7ece86a3c3a0a5ca58bf2e0768a86 "1"^^ . +_:f2d7ece86a3c3a0a5ca58bf2e0768a86 "1"^^ . +_:908a0ba1ec609e7248b97d7c5fce2abe . +_:908a0ba1ec609e7248b97d7c5fce2abe . +_:908a0ba1ec609e7248b97d7c5fce2abe "A DifferentialSensor must be associated with exactly 1 of Connectable, Connection, or ConnectionPoint using the relation hasObservationLocationLow." . +_:908a0ba1ec609e7248b97d7c5fce2abe "1"^^ . +_:908a0ba1ec609e7248b97d7c5fce2abe "1"^^ . +_:e32f3d917da2a5c8d943e7b9917ec10a . +_:e32f3d917da2a5c8d943e7b9917ec10a _:42db59df61615cd48d91e2fa6c47994e . +_:e32f3d917da2a5c8d943e7b9917ec10a "An ElectricTransformer shall have at least one outlet using the medium Electricity." . +_:e32f3d917da2a5c8d943e7b9917ec10a "1"^^ . +_:e32f3d917da2a5c8d943e7b9917ec10a "1"^^ . +_:2566147f4c5bd103ce3af497317b75ea . +_:2566147f4c5bd103ce3af497317b75ea _:3a0f31c4d3a235394485fa1fe34f1bf8 . +_:ba24d74c3fdb56d5ed6dd698fb179562 _:9e0437f98ffb3e24c0761ba7ba7ec843 . +_:7b072d57514167d67fe9f9cfadf16e89 . +_:7b072d57514167d67fe9f9cfadf16e89 _:9a06fa83d852ed9ce020cea04d84911b . +_:25e261857ae23f79d102443bcb6d9b17 . +_:25e261857ae23f79d102443bcb6d9b17 . +_:5fb821d6a0a26ddfdd9b9ecd790a5a65 _:4ad35ae61e2024c8dd79fa4f0fc6781d . +_:221ae96653a94bccfd47900e94ff542f . +_:221ae96653a94bccfd47900e94ff542f _:5a80daf25f013cb7c3b488e985256d6 . +_:221ae96653a94bccfd47900e94ff542f "A SingleDuctTerminal must be associated with at least one Damper using the relation contains." . +_:221ae96653a94bccfd47900e94ff542f "1"^^ . +_:221ae96653a94bccfd47900e94ff542f "1"^^ . +_:15e54beab70574778e52e8706f8066d9 _:f3bdccc2913dd3b253841d02a317cc70 . +_:6c63e3be6fe841a65e312db5b1d9ddf . +_:6c63e3be6fe841a65e312db5b1d9ddf _:a0ef80cec8e2465264ef4d1da0dcc96e . +_:6c63e3be6fe841a65e312db5b1d9ddf "A Motor shall have at least one inlet using the medium Electricity." . +_:6c63e3be6fe841a65e312db5b1d9ddf "1"^^ . +_:6c63e3be6fe841a65e312db5b1d9ddf "1"^^ . +_:f9ef661fc5d94407792f69d006c2903 . +_:f9ef661fc5d94407792f69d006c2903 _:7c49476a07e135bf05529304bf0f0046 . +_:22863055bb6ea4c02d4f5acbb485e8c8 . +_:22863055bb6ea4c02d4f5acbb485e8c8 _:78261b5183a880c23749a0c4339134af . +_:9e0437f98ffb3e24c0761ba7ba7ec843 . +_:9e0437f98ffb3e24c0761ba7ba7ec843 . +_:766b541fa55821a783f3c63e86428bf9 _:a39984eea61bab745adde9be490b4140 . +_:383d85ed5dfc61c58a2b3d6584181429 . +_:383d85ed5dfc61c58a2b3d6584181429 . +_:383d85ed5dfc61c58a2b3d6584181429 "If the relation mapsTo is present it must associate the OutletConnectionPoint with an OutletConnectionPoint." . +_:e6c0d3cf88a3a64464b79f3cdbe5d740 _:8fcce3264757cbb422671b44fee9dee . +_:7254df18c0ac28025b2c14f840d7bd4 _:ef2cc4e44b5ebe9e45dd97294a918415 . +_:7254df18c0ac28025b2c14f840d7bd4 . +_:4c1331fe6c270cdc19bb3d864fef20f0 . +_:4c1331fe6c270cdc19bb3d864fef20f0 . +_:2b324b43f968b3f887f5c518136f6ef4 . +_:fe638124251c4666edeb655dee22ee3c . +_:fe638124251c4666edeb655dee22ee3c . +_:6401c5f8f09e0cfe2dbcecfbdec2e88d . +_:6401c5f8f09e0cfe2dbcecfbdec2e88d "s223: A ConnectionPoint can be associated with at most one other ConnectionPoint using the inverse of relation mapsTo" . +_:6401c5f8f09e0cfe2dbcecfbdec2e88d _:5c356b80419b2eec751643315596108c . +_:6401c5f8f09e0cfe2dbcecfbdec2e88d "A ConnectionPoint can be associated with at most one other ConnectionPoint using the inverse of relation mapsTo" . +_:6401c5f8f09e0cfe2dbcecfbdec2e88d "1"^^ . +_:5ef140b2f3b63118de8db9408754403d . +_:5ef140b2f3b63118de8db9408754403d _:6b6bb7bd06df16720ac6f9b942c5c084 . +_:f469177d63d0be8315ea7380178c1f7b _:13e9301f028eb951dbc389d4d76ba1ec . +_:eb057ab8226ecfea2882af6de48ff9e5 _:e58f795cbc961b6baf989b84da78b522 . +_:498e492a215af6cb76fbc11069f7d55e "Water conc" . +_:498e492a215af6cb76fbc11069f7d55e . +_:498e492a215af6cb76fbc11069f7d55e . +_:498e492a215af6cb76fbc11069f7d55e . +_:498e492a215af6cb76fbc11069f7d55e . +_:498e492a215af6cb76fbc11069f7d55e "85"^^ . +_:b47b63dfccb019eb813769a282cc6b46 . +_:b47b63dfccb019eb813769a282cc6b46 . +_:b47b63dfccb019eb813769a282cc6b46 "If the relation hasRole is present it must associate the ConnectionPoint with an EnumerationKind-Role." . +_:64a1d56976bd07bb0dcc1826a61d508d . +_:64a1d56976bd07bb0dcc1826a61d508d _:26a31ddfcb00ef4aaf051012e960fe45 . +_:64a1d56976bd07bb0dcc1826a61d508d "A Pump shall have at least one outlet using the medium Water, Oil or Refrigerant." . +_:64a1d56976bd07bb0dcc1826a61d508d "1"^^ . +_:64a1d56976bd07bb0dcc1826a61d508d "1"^^ . +_:2270e649fce0d5a5877b8f30f3929759 _:fe638124251c4666edeb655dee22ee3c . +_:8233c4ec3e3faf9dd3a32113f1069dec . +_:8233c4ec3e3faf9dd3a32113f1069dec "s223: A Zone must be associated with exactly one EnumerationKind-Domain using the relation hasDomain." . +_:8233c4ec3e3faf9dd3a32113f1069dec . +_:8233c4ec3e3faf9dd3a32113f1069dec "A Zone must be associated with exactly one EnumerationKind-Domain using the relation hasDomain." . +_:8233c4ec3e3faf9dd3a32113f1069dec "1"^^ . +_:8233c4ec3e3faf9dd3a32113f1069dec "1"^^ . +_:2cd5917cf22ca8f12eb56b10d6dcab2f . +_:2cd5917cf22ca8f12eb56b10d6dcab2f . +_:46bc4ee0ca3c1ab71d0968925ced71eb "Unspecified" . +_:46bc4ee0ca3c1ab71d0968925ced71eb . +_:46bc4ee0ca3c1ab71d0968925ced71eb . +_:d30734b13830ec4d61641cb9890706b5 . +_:d30734b13830ec4d61641cb9890706b5 _:2de1b533e3ddfb3904a87944e514b6c9 . +_:51de263df76cc82ba99f94c6e2bd0615 . +_:51de263df76cc82ba99f94c6e2bd0615 _:c8dc541a26fe365ccf3161c7b994780d . +_:243b218e66e4b92119b04af8d01d20b _:2ffebd6c5239e8a2343b663ff752cb8a . +_:978377bbe56b757b9b5b376bab5fd5d2 "true"^^ . +_:978377bbe56b757b9b5b376bab5fd5d2 "s223: A ConnectionPoint must be associated with at most one Connectable using the cnx relation." . +_:978377bbe56b757b9b5b376bab5fd5d2 . +_:978377bbe56b757b9b5b376bab5fd5d2 _:5b11044d8c0c764475656a2302560024 . +_:978377bbe56b757b9b5b376bab5fd5d2 "A ConnectionPoint must be associated with at most one Connectable using the cnx relation." . +_:978377bbe56b757b9b5b376bab5fd5d2 "1"^^ . +_:1e7f4fd378689e508fa386218911397d . +_:1e7f4fd378689e508fa386218911397d "s223: A Connection must be associated with exactly one Substance-Medium using the relation hasMedium." . +_:1e7f4fd378689e508fa386218911397d . +_:1e7f4fd378689e508fa386218911397d "A Connection must be associated with exactly one Substance-Medium using the relation hasMedium." . +_:1e7f4fd378689e508fa386218911397d "Connection medium" . +_:1e7f4fd378689e508fa386218911397d "1"^^ . +_:1e7f4fd378689e508fa386218911397d "1"^^ . +_:f0753d2614467f1c6ef341dafdd0a48f . +_:f0753d2614467f1c6ef341dafdd0a48f _:2e2b461b88062b1edb991a241c132d31 . +_:37c2b264e5606e0102e078224eff02a3 . +_:ffc0d00dd61f654337d4e55ea6b3fb20 . +_:ffc0d00dd61f654337d4e55ea6b3fb20 _:ae87b6c4a2ba1139c796c933af79e23 . +_:ffc0d00dd61f654337d4e55ea6b3fb20 "An AirHandlingUnit shall have at least one outlet using the medium Air." . +_:ffc0d00dd61f654337d4e55ea6b3fb20 "1"^^ . +_:ffc0d00dd61f654337d4e55ea6b3fb20 "1"^^ . +_:dba040fbb1018caba907c2cc8bb65865 . +_:dba040fbb1018caba907c2cc8bb65865 _:387cdc595f8f479d8b1b444385bbf2f . +_:dba040fbb1018caba907c2cc8bb65865 "A FanCoilUnit must be associated with at least 1 Fan using the relation contains." . +_:dba040fbb1018caba907c2cc8bb65865 "1"^^ . +_:dba040fbb1018caba907c2cc8bb65865 "1"^^ . +_:a5ffb6a87f3ee8ca58ec615fff43b551 _:908a0ba1ec609e7248b97d7c5fce2abe . +_:917e51c837f1e479d76a4079541b65d4 . +_:e58f795cbc961b6baf989b84da78b522 . +_:e58f795cbc961b6baf989b84da78b522 . +_:c66e2c13a5c4f119d9efd20a8ac67bbe . +_:c66e2c13a5c4f119d9efd20a8ac67bbe _:ff2455033f89fa0891f48b239f9862bc . +_:c66e2c13a5c4f119d9efd20a8ac67bbe "A TerminalUnit shall have at least one outlet ConnectionPoint using the medium Air." . +_:c66e2c13a5c4f119d9efd20a8ac67bbe "1"^^ . +_:c66e2c13a5c4f119d9efd20a8ac67bbe "1"^^ . +_:55f2000eaab60457da36ffd0c3231da8 . +_:55f2000eaab60457da36ffd0c3231da8 "A Turbine must be associated with at least one ConnectionPoint using the relation hasConnectionPoint." . +_:55f2000eaab60457da36ffd0c3231da8 "1"^^ . +_:9614d22eb75aefc47f9df60333e0569c . +_:9614d22eb75aefc47f9df60333e0569c _:7a682678d5bcb8069a14533c6d2cb9db . +_:9614d22eb75aefc47f9df60333e0569c "A TerminalUnit shall have at least one inlet ConnectionPoint using the medium Air." . +_:9614d22eb75aefc47f9df60333e0569c "1"^^ . +_:9614d22eb75aefc47f9df60333e0569c "1"^^ . +_:ae87b6c4a2ba1139c796c933af79e23 . +_:ae87b6c4a2ba1139c796c933af79e23 _:e9f45fa42723dde6b5aec375efd03ba0 . +_:acf271b522b7f713d4920c33e9729e93 . +_:acf271b522b7f713d4920c33e9729e93 "s223: A System should be associated with at least two instances of Equipment or System using the relation hasMember" . +_:acf271b522b7f713d4920c33e9729e93 . +_:acf271b522b7f713d4920c33e9729e93 . +_:acf271b522b7f713d4920c33e9729e93 "A System should be associated with at least two instances of Equipment or System using the relation hasMember" . +_:acf271b522b7f713d4920c33e9729e93 _:e562bad29e14c68cbfd35696f6d99d13 . +_:acf271b522b7f713d4920c33e9729e93 "2"^^ . +_:9fcfe8651b217d03632c0a71d5dc83d0 . +_:9fcfe8651b217d03632c0a71d5dc83d0 "If the relation hasElectricalPhase is present it must associate the ConnectionPoint with an ElectricalPhaseIdentifier or ElectricalVoltagePhases." . +_:9fcfe8651b217d03632c0a71d5dc83d0 _:8b9e613340cab2a7282079a2e20f8652 . +_:7a05d78d3854318d55a6af02e5d75362 _:f01077899fe376410cc4a07e5ff882c2 . +_:282431aa52007b83d1b2bfc5c4965982 . +_:282431aa52007b83d1b2bfc5c4965982 _:c3794b65b8c7871b0d82edadd210f994 . +_:282431aa52007b83d1b2bfc5c4965982 "Radiators must have the role Role-Heating." . +_:282431aa52007b83d1b2bfc5c4965982 "1"^^ . +_:282431aa52007b83d1b2bfc5c4965982 "1"^^ . +_:c28effc05f4c161db34d4d2fb6f44967 . +_:c28effc05f4c161db34d4d2fb6f44967 _:8a6a52713f87e45e449d4f5d963345bd . +_:c28effc05f4c161db34d4d2fb6f44967 "An EthernetSwitch shall have at least two BidirectionalConnectionPoints using the medium Signal-Ethernet." . +_:c28effc05f4c161db34d4d2fb6f44967 "2"^^ . +_:4c0348ab36904e46479589a86f9e0c64 . +_:66eb3f999e0f68946c18bc480d771dd5 . +_:d83615ca483e69a5cedb2cafbead31b2 . +_:d83615ca483e69a5cedb2cafbead31b2 . +_:d83615ca483e69a5cedb2cafbead31b2 _:6b8e6dc753e1bb2cfbc4a403fd6fc69b . +_:d83615ca483e69a5cedb2cafbead31b2 "A VariableFrequencyDrive shall have at least one inlet using the medium Electricity." . +_:d83615ca483e69a5cedb2cafbead31b2 "1"^^ . +_:d83615ca483e69a5cedb2cafbead31b2 "1"^^ . +_:49d08b7aba86edbcbcc6576d723500f7 . +_:49d08b7aba86edbcbcc6576d723500f7 . +_:49d08b7aba86edbcbcc6576d723500f7 "A Numerical-Frequency must have a unit of Hertz" . +_:fe7166b35c6b720555082502b1575e89 . +_:fe7166b35c6b720555082502b1575e89 _:a724e09a67cd607cc245c66e1932427f . +_:fe7166b35c6b720555082502b1575e89 "An AirHandlingUnit shall have at least one inlet using the medium Air." . +_:fe7166b35c6b720555082502b1575e89 "1"^^ . +_:fe7166b35c6b720555082502b1575e89 "1"^^ . +_:90167de3152c17f1c899809c4ac01651 _:ffa0f48380ae1625fdce34db7323dde8 . +_:f2c980d77abab96bb85c5ac404298ea9 . +_:f2c980d77abab96bb85c5ac404298ea9 . +_:f2c980d77abab96bb85c5ac404298ea9 "If the relation mapsTo is present it must associate the InletConnectionPoint with an InletConnectionPoint." . +_:d990352c73865e62b736b09bcd14eb9a _:12c7b3d01fedb258cd1004fab20d7214 . +_:ae8b3960252883f6ee134769ec9bef44 . +_:ae8b3960252883f6ee134769ec9bef44 _:bd0ca9e5db40b6ac7481af1a3f60043d . +_:f2e2312a8222db1335ed62684fe7d070 _:31ea85fec81383339c6a8bc32b394c38 . +_:4e5cdde94039ec9b269867e29fc848a6 _:e4ea2785e2693bdf93b78b256c5ea050 . +_:4e5cdde94039ec9b269867e29fc848a6 _:48583ebe8481b17bdc757c8d085ad412 . +_:1846be8a2d082f645ab7d5e3ddca6505 . +_:1846be8a2d082f645ab7d5e3ddca6505 _:e0afb8176b645e0787919040a91259c6 . +_:2bd319fce4652882f67c1f0c1f6608d6 . +_:2bd319fce4652882f67c1f0c1f6608d6 . +_:eb672900d92f5273b1f24407c88124a4 . +_:eb672900d92f5273b1f24407c88124a4 . +_:eb672900d92f5273b1f24407c88124a4 "s223: This ConnectionPoint must be associated with at most one Connection." . +_:eb672900d92f5273b1f24407c88124a4 . +_:eb672900d92f5273b1f24407c88124a4 "A ConnectionPoint must be associated with at most one Connection using the relation connectsThrough." . +_:eb672900d92f5273b1f24407c88124a4 "ConnectionPointToConnectionShape" . +_:eb672900d92f5273b1f24407c88124a4 "1"^^ . +_:8a6a52713f87e45e449d4f5d963345bd . +_:8a6a52713f87e45e449d4f5d963345bd _:a17ab4009e12878182c8631defba1119 . +_:78f3339dd3b49b6b4e52799e2486224 . +_:78f3339dd3b49b6b4e52799e2486224 . +_:78f3339dd3b49b6b4e52799e2486224 "If the relation hasInput is present it must associate a Function with a Property." . +_:db40279eebcb8282f63546802fdc5998 . +_:db40279eebcb8282f63546802fdc5998 . +_:391acaf117a9469339fb0e23a1d83ca7 _:da0ff443374babf86c84fe5277370923 . +_:391acaf117a9469339fb0e23a1d83ca7 _:6917cf95fc3df4640d55f0d6d29b1d42 . +_:9f6a31ce14ef231026f0744757616eeb _:1f2704e560ddcc85de8523b41bab6540 . +_:9f6a31ce14ef231026f0744757616eeb _:7b894eabb5f35fe673922ee16e5fb3bf . +_:89981df6ed1f3dfee047766481b4167d . +_:a63d0e545f4641fd0e26885d59bf7231 . +_:a63d0e545f4641fd0e26885d59bf7231 _:72aa6723f092566666a020c1f74b9113 . +_:315b9c3fd5f37c7ea685b8dd832e4191 . +_:315b9c3fd5f37c7ea685b8dd832e4191 . +_:315b9c3fd5f37c7ea685b8dd832e4191 "If the relation cnx is present it must associate the Connectable with a ConnectionPoint." . +_:1d630b704aa49026df640a762ff01dc1 . +_:1d630b704aa49026df640a762ff01dc1 _:77067067615d9e709317f18bb402d021 . +_:1d630b704aa49026df640a762ff01dc1 "A Coil shall have at least one inlet using the medium Air." . +_:1d630b704aa49026df640a762ff01dc1 "1"^^ . +_:1d630b704aa49026df640a762ff01dc1 "1"^^ . +_:dfe5e8bdfb3e2a78d754d4023229a6d1 . +_:dfe5e8bdfb3e2a78d754d4023229a6d1 _:d30734b13830ec4d61641cb9890706b5 . +_:dfe5e8bdfb3e2a78d754d4023229a6d1 "A CoolingTower shall have at least one outlet using the medium Water." . +_:dfe5e8bdfb3e2a78d754d4023229a6d1 "1"^^ . +_:dfe5e8bdfb3e2a78d754d4023229a6d1 "1"^^ . +_:b26ba634b5147f7631e4c6bdc6b0c1a7 . +_:b26ba634b5147f7631e4c6bdc6b0c1a7 . +_:b26ba634b5147f7631e4c6bdc6b0c1a7 "If the relation hasProperty is present, it must associate the concept with a Property." . +_:fc51b951887184991ca68635f10efde9 . +_:fc51b951887184991ca68635f10efde9 _:aa3d7f600c731f2598cc869d1255073b . +_:fc51b951887184991ca68635f10efde9 "A radiant panel must hasRole Role-Heating." . +_:fc51b951887184991ca68635f10efde9 "1"^^ . +_:fc51b951887184991ca68635f10efde9 "1"^^ . +_:119044564bb04f492f7c3eae52cf79af _:f9ef661fc5d94407792f69d006c2903 . +_:119044564bb04f492f7c3eae52cf79af _:79d2c172639ea183e9c175465e679f12 . +_:98751a5d4737bda38d40f8c1d5a5edd3 . +_:98751a5d4737bda38d40f8c1d5a5edd3 "s223: An EnumerableProperty must be associated with exactly one EnumerationKind using the relation hasEnumerationKind." . +_:98751a5d4737bda38d40f8c1d5a5edd3 . +_:98751a5d4737bda38d40f8c1d5a5edd3 "An EnumerableProperty must be associated with exactly one EnumerationKind using the relation hasEnumerationKind." . +_:98751a5d4737bda38d40f8c1d5a5edd3 "1"^^ . +_:98751a5d4737bda38d40f8c1d5a5edd3 "1"^^ . +_:7066e24d05741dc4013b7f5f6c929bda . +_:ee4ebe3316d652b0bf6b99b1f171c094 _:16c4dc01f6bca255b7d92234c12e447 . +_:7c83cd5aeb51607337f839bcba23943 _:c4b5c77a022e1e7acfa6ebddf5fc9b1 . +_:cc5482412827252a4345ebdd4691ecac . +_:cc5482412827252a4345ebdd4691ecac _:c49b2d3ff4831cf13884961e56a39ce9 . +_:cc5482412827252a4345ebdd4691ecac "An ElectricOutlet shall have exactly one inlet using the medium Electricity." . +_:cc5482412827252a4345ebdd4691ecac "1"^^ . +_:cc5482412827252a4345ebdd4691ecac "1"^^ . +_:cc5482412827252a4345ebdd4691ecac "1"^^ . +_:a39984eea61bab745adde9be490b4140 . +_:a39984eea61bab745adde9be490b4140 . +_:7d1869db5fb5be9eb41bb27f0f4d9d72 . +_:7d1869db5fb5be9eb41bb27f0f4d9d72 . +_:7d1869db5fb5be9eb41bb27f0f4d9d72 "A DC-Voltage must have a voltage" . +_:7d1869db5fb5be9eb41bb27f0f4d9d72 "1"^^ . +_:387cdc595f8f479d8b1b444385bbf2f . +_:1b27814b932b91e1e7322f0bd9b25f8 . +_:1b27814b932b91e1e7322f0bd9b25f8 . +_:890122351aab8f5bdf001683d63658a3 . +_:890122351aab8f5bdf001683d63658a3 . +_:890122351aab8f5bdf001683d63658a3 "An AC-Numerical-LineNeutralVoltage must have a voltage" . +_:890122351aab8f5bdf001683d63658a3 "1"^^ . +_:c9e4e4663c82b4060c4d94233734b460 _:df4bc6486690fb4aedc123459de77a94 . +_:871195daec5d6a53f7b1eac6fcadd922 . +_:871195daec5d6a53f7b1eac6fcadd922 . +_:871195daec5d6a53f7b1eac6fcadd922 "If the relation connectsTo is present it must associate the Connection with a Connectable." . +_:871195daec5d6a53f7b1eac6fcadd922 "ConnectionToDownstreamConnectableShape" . +_:b9142f83756c17e4a42f67d457c7abf1 . +_:b9142f83756c17e4a42f67d457c7abf1 . +_:b5b1f29dd65231264db614415327b112 . +_:b5b1f29dd65231264db614415327b112 . +_:282dbe68c0360b160ddf4e36b93795d4 . +_:282dbe68c0360b160ddf4e36b93795d4 _:4a6c14a5915338c79d51cb0d573ea3cf . +_:282dbe68c0360b160ddf4e36b93795d4 "A VariableFrequencyDrive shall have at least one outlet using the medium Electricity." . +_:282dbe68c0360b160ddf4e36b93795d4 "1"^^ . +_:282dbe68c0360b160ddf4e36b93795d4 "1"^^ . +_:3617ec7c7f850ace24ae62771f98c1f9 . +_:7c49476a07e135bf05529304bf0f0046 _:96a3ca395015cf4b21b35e2764010a11 . +_:ad69e14c6ae82acb4ab45651fb608dac . +_:ad69e14c6ae82acb4ab45651fb608dac . +_:ad69e14c6ae82acb4ab45651fb608dac "If the relation hasMeasurementResolution is present it must associate the AbstractSensor with a QuantifiableProperty." . +_:1543c07273c93fc67729bc52beeae6bb . +_:1543c07273c93fc67729bc52beeae6bb _:77ff7c01b56527c965cc2f9135de97be . +_:fbcc130cef713d84a3d95394e21ae6ad . +_:fbcc130cef713d84a3d95394e21ae6ad . +_:eee4fb4350adb47e3878ebe1fb980037 . +_:eee4fb4350adb47e3878ebe1fb980037 _:54dceda577190e4943006c5c2d33af9b . +_:c49b2d3ff4831cf13884961e56a39ce9 . +_:c49b2d3ff4831cf13884961e56a39ce9 _:d69df34daaae75473a27d0147b398250 . +_:84f62142f084f5b3878a6e7025c483e _:288edac29e8c6a717bb0e0b545dd597b . +_:ffa0f48380ae1625fdce34db7323dde8 . +_:ffa0f48380ae1625fdce34db7323dde8 . +_:76ddc1b8ad3394271f05d23b3e437f9 . +_:76ddc1b8ad3394271f05d23b3e437f9 . +_:76ddc1b8ad3394271f05d23b3e437f9 "An EnumerationKind-Numerical can be associated with a decimal value using the relation hasValue." . +_:1684ec59400f66c29cca19c63d4ddd44 _:a0e0e7d217bc1acc9c9ae241695aaf27 . +_:1684ec59400f66c29cca19c63d4ddd44 _:66eb3f999e0f68946c18bc480d771dd5 . +_:88b8f718c634fe9b69eb3d1e3ba4cd2 . +_:88b8f718c634fe9b69eb3d1e3ba4cd2 . +_:1162af531f24bd6fd5d8b8e2ae5b80fb . +_:1162af531f24bd6fd5d8b8e2ae5b80fb . +_:25b1700cb5fc47e1006c1aba3c714d11 . +_:25b1700cb5fc47e1006c1aba3c714d11 . +_:25b1700cb5fc47e1006c1aba3c714d11 "If the relation connectedThrough is present it must associate the Connectable with a Connection." . +_:25b1700cb5fc47e1006c1aba3c714d11 "EquipmentToConnectionShape" . +_:5baf2ba5ab97c565dfd971d8f0d25d1 . +_:5baf2ba5ab97c565dfd971d8f0d25d1 _:4080180b2636f557d12460afcd997aeb . +_:85cb6f45c193d67f2e8c20f6c724bdb6 . +_:85cb6f45c193d67f2e8c20f6c724bdb6 _:a855ac793627d2d83563a3b96fffc38a . +_:85cb6f45c193d67f2e8c20f6c724bdb6 "A SolarThermalCollector shall have at least one outlet using the medium Water." . +_:85cb6f45c193d67f2e8c20f6c724bdb6 "1"^^ . +_:85cb6f45c193d67f2e8c20f6c724bdb6 "1"^^ . +_:cc2b0acccb3b90185b994a5e1a6457d8 . +_:cc2b0acccb3b90185b994a5e1a6457d8 . +_:cc2b0acccb3b90185b994a5e1a6457d8 "If the relation connectedTo is present it must associate the VariableFrequencyDrive with a Equipment." . +_:3e84c32cc8d9c4c5b4d3734ceb95c07a _:98fdca6f66c6305c252efe70af3ecd30 . +_:36e7a18ce65cc04f24d4a67f6820a4c6 . +_:36e7a18ce65cc04f24d4a67f6820a4c6 "s223: A Property can be associated with at most one Function using the inverse relation hasOutput." . +_:36e7a18ce65cc04f24d4a67f6820a4c6 _:2dde4d69e6474ac841843946d942a22c . +_:36e7a18ce65cc04f24d4a67f6820a4c6 "A Property can be associated with at most one Function using the inverse relation hasOutput." . +_:36e7a18ce65cc04f24d4a67f6820a4c6 "1"^^ . +_:b9ffa77955bdd15854905fff5b8fb9f9 . +_:b9ffa77955bdd15854905fff5b8fb9f9 _:58891e0b0fa894b80ccb390305b4147b . +_:b9ffa77955bdd15854905fff5b8fb9f9 "A HeatPump shall have at least one inlet using the medium Air." . +_:b9ffa77955bdd15854905fff5b8fb9f9 "1"^^ . +_:b9ffa77955bdd15854905fff5b8fb9f9 "1"^^ . +_:bcbb80f3b4303e46d075ca4b4a3ea897 . +_:bcbb80f3b4303e46d075ca4b4a3ea897 _:5ef140b2f3b63118de8db9408754403d . +_:bcbb80f3b4303e46d075ca4b4a3ea897 "One of the constituents of a Water-GlycolSolution must be Medium-Glycol." . +_:bcbb80f3b4303e46d075ca4b4a3ea897 "1"^^ . +_:323b635d5d3193a8bc4a95abbff38b3f . +_:323b635d5d3193a8bc4a95abbff38b3f "An electricity DC medium must have two reference voltages." . +_:323b635d5d3193a8bc4a95abbff38b3f _:7432046153f89dcfc8e0a5ab047e9a5 . +_:323b635d5d3193a8bc4a95abbff38b3f "1"^^ . +_:43d9eecac85a3bedb97d80571d96fd4a . +_:43d9eecac85a3bedb97d80571d96fd4a . +_:43d9eecac85a3bedb97d80571d96fd4a "A Thermal Energy Storage Unit must have at least two connection points." . +_:43d9eecac85a3bedb97d80571d96fd4a "2"^^ . +_:4375abb21156f3ec40568e9f5c6200a1 _:e17a9c0100ba71a41fe04f89b8d305cf . +_:a47947f7c508dde3d1bdb57e5e3762a9 . +_:a47947f7c508dde3d1bdb57e5e3762a9 _:7c83cd5aeb51607337f839bcba23943 . +_:2dde4d69e6474ac841843946d942a22c . +_:29a3d60b4039dd939173c3f9ff92f409 . +_:3250e3df89b16ee3056dd73a8b3b22fc . +_:3250e3df89b16ee3056dd73a8b3b22fc _:e3869c16ca6cfb7ba9021c41b8423e0c . +_:3250e3df89b16ee3056dd73a8b3b22fc "A Window shall have at least one outlet using the medium Light." . +_:3250e3df89b16ee3056dd73a8b3b22fc "1"^^ . +_:3250e3df89b16ee3056dd73a8b3b22fc "1"^^ . +_:feae27801a522fd06eb92e99e1225c43 _:42902de475c49b823c68508cabe14349 . +_:f5cf8bc08a5c64ca7c023523b0d28d52 . +_:f5cf8bc08a5c64ca7c023523b0d28d52 _:daaad51b1c141b833f45c6246d075ccf . +_:11c3891175435ad2ec45e9fe12a45c5b . +_:11c3891175435ad2ec45e9fe12a45c5b . +_:6e3479cf2caf67ad840d852fd2a007a6 _:ba444d29daeef1bca023979960a4c969 . +_:bf101fdfdde1fbe9e6354db90d59a95f . +_:bf101fdfdde1fbe9e6354db90d59a95f _:2755b05cc3f99ef4fa0965334d7d8793 . +_:bf101fdfdde1fbe9e6354db90d59a95f "ResistanceHeaters must have the role Role-Heating." . +_:bf101fdfdde1fbe9e6354db90d59a95f "1"^^ . +_:bf101fdfdde1fbe9e6354db90d59a95f "1"^^ . +_:765da9cb0adf91cf37fddd0af4dbe240 . +_:765da9cb0adf91cf37fddd0af4dbe240 . +_:765da9cb0adf91cf37fddd0af4dbe240 "If the relation connectedTo is present it must associate the Connectable with a Connectable." . +_:765da9cb0adf91cf37fddd0af4dbe240 "ConnectableToConnectableShape" . +_:46812907fd0fa7541e988fa73b443666 . +_:46812907fd0fa7541e988fa73b443666 . +_:46812907fd0fa7541e988fa73b443666 "If the relation contains is present it must associate the Equipment with either Equipment or Junction." . +_:46812907fd0fa7541e988fa73b443666 _:3c86e61ef03ace1cbddfba43c0126d9c . +_:46812907fd0fa7541e988fa73b443666 "device contains shape" . +_:e3869c16ca6cfb7ba9021c41b8423e0c . +_:e3869c16ca6cfb7ba9021c41b8423e0c _:c6ea4a8f89ae6e117712b5ad34fbae24 . +_:204d21e0961486f298b55ac6cbfb88c2 . +_:204d21e0961486f298b55ac6cbfb88c2 _:65607bc361b8adebaef61f46dc5601f6 . +_:204d21e0961486f298b55ac6cbfb88c2 "An Inverter shall have at least one inlet using the medium Electricity-DC." . +_:204d21e0961486f298b55ac6cbfb88c2 "1"^^ . +_:204d21e0961486f298b55ac6cbfb88c2 "1"^^ . +_:d296b3209601f7994d769d34bfa76138 . +_:d296b3209601f7994d769d34bfa76138 . +_:7a5a77390394b6392fa07983e2fc2cd5 _:f1f1c2cbccd9a5570133b29b9664e8f4 . +_:406775bde1ee60f147fa1796a81ca46 . +_:203ca0c2a79b6ce7bb5f3e0be5c18e07 . +_:203ca0c2a79b6ce7bb5f3e0be5c18e07 . +_:203ca0c2a79b6ce7bb5f3e0be5c18e07 "A Sensor must be associated with exactly 1 of Connectable, Connection, or ConnectionPoint using the relation hasObservationLocation." . +_:203ca0c2a79b6ce7bb5f3e0be5c18e07 "1"^^ . +_:203ca0c2a79b6ce7bb5f3e0be5c18e07 "1"^^ . +_:7a682678d5bcb8069a14533c6d2cb9db . +_:7a682678d5bcb8069a14533c6d2cb9db _:b81743758ff9978924b3932cd554bb05 . +_:bce65c594669063d2855e16eed0c3be9 "Water conc" . +_:bce65c594669063d2855e16eed0c3be9 . +_:bce65c594669063d2855e16eed0c3be9 . +_:bce65c594669063d2855e16eed0c3be9 . +_:bce65c594669063d2855e16eed0c3be9 . +_:bce65c594669063d2855e16eed0c3be9 "70"^^ . +_:79f3f5249359e8a57ddad97fc708f9f3 "1"^^ . +_:cee8b7ad6f12c6f1e67bacbb18156453 . +_:cee8b7ad6f12c6f1e67bacbb18156453 _:2270e649fce0d5a5877b8f30f3929759 . +_:c2844109db8c8de4e55368b90bc553c6 . +_:c2844109db8c8de4e55368b90bc553c6 "s223: A Property can be associated with at most one EnumerationKind-Medium using the relation ofMedium." . +_:c2844109db8c8de4e55368b90bc553c6 . +_:c2844109db8c8de4e55368b90bc553c6 "A Property can be associated with at most one EnumerationKind-Medium using the relation ofMedium." . +_:c2844109db8c8de4e55368b90bc553c6 "1"^^ . +_:a103f74164f4edc05d87afe301a0eba3 . +_:a103f74164f4edc05d87afe301a0eba3 . +_:a103f74164f4edc05d87afe301a0eba3 "If the relation hasRole is present, it must associate the System with an EnumerationKind-Role." . +_:4657d03dd1f55d64cffd056a1c018225 . +_:4657d03dd1f55d64cffd056a1c018225 _:eee4fb4350adb47e3878ebe1fb980037 . +_:4657d03dd1f55d64cffd056a1c018225 "A FumeHood shall have at least one inlet using the medium Air." . +_:4657d03dd1f55d64cffd056a1c018225 "1"^^ . +_:4657d03dd1f55d64cffd056a1c018225 "1"^^ . +_:f1f1c2cbccd9a5570133b29b9664e8f4 . +_:f1f1c2cbccd9a5570133b29b9664e8f4 . +_:97db336542db167405cd5153146eee1d . +_:97db336542db167405cd5153146eee1d . +_:d65a5d56f3822a1dbe8f073922a61c3e _:db40279eebcb8282f63546802fdc5998 . +_:beafdb1f2b27923f90a613548785a008 . +_:beafdb1f2b27923f90a613548785a008 . +_:beafdb1f2b27923f90a613548785a008 "There must be at least two QuantifiableProperties that characterize the constituents of a Water-GlycolSolution." . +_:beafdb1f2b27923f90a613548785a008 "2"^^ . +_:c3794b65b8c7871b0d82edadd210f994 . +_:fcac579569ab26f0d656cb966ebd4848 . +_:fcac579569ab26f0d656cb966ebd4848 . +_:b19c54017ec3cc6e8afc3c518579da40 . +_:b19c54017ec3cc6e8afc3c518579da40 _:ccd8b6720490240c84be9d5cde61efa7 . +_:c23a62c9e2c9c9594543d712bb4fd042 . +_:c23a62c9e2c9c9594543d712bb4fd042 _:362b6a303f1180c08b0124f7ef9f6b60 . +_:471ac808d07065ea3dca6e53e251bcce "s223: A Property can use at most one relation hasValue if it is required to provide a static value in the model. It is not meant for real-time value (see `s223:hasExternalReference`)." . +_:471ac808d07065ea3dca6e53e251bcce . +_:471ac808d07065ea3dca6e53e251bcce "A Property can use at most one relation hasValue if it is required to provide a static value in the model. It is not meant for real-time value (see `s223:hasExternalReference`)." . +_:471ac808d07065ea3dca6e53e251bcce "1"^^ . +_:eb8ccad4fd958c6f4dd86b719d014b4a . +_:eb8ccad4fd958c6f4dd86b719d014b4a _:db31657720e710779bf647f5b9fb465d . +_:eb8ccad4fd958c6f4dd86b719d014b4a "An ElectricOutlet shall have at least one outlet using the medium Electricity." . +_:eb8ccad4fd958c6f4dd86b719d014b4a "1"^^ . +_:eb8ccad4fd958c6f4dd86b719d014b4a "1"^^ . +_:7b894eabb5f35fe673922ee16e5fb3bf _:32aefca0c68e9dcc3cfe2807b444ab74 . +_:7b59e4fbc1fa4bd2030bd4cef5c08b92 "s223: An EnumerationKind must not use the generalized hasProperty relation. EnumerationKind is a controlled vocabulary which must not be modified within a model." . +_:7b59e4fbc1fa4bd2030bd4cef5c08b92 . +_:7b59e4fbc1fa4bd2030bd4cef5c08b92 "An EnumerationKind must not use the generalized hasProperty relation. Some EnumerationKinds have specifically-defined relations to Property." . +_:7b59e4fbc1fa4bd2030bd4cef5c08b92 "0"^^ . +_:6dc32855ccc2d33fe259e6d3cd417770 . +_:6dc32855ccc2d33fe259e6d3cd417770 . +_:aa3d7f600c731f2598cc869d1255073b . +_:93e730cdd7c302128e3b63f8479c4d6f _:252cc98a22db34128df832a79414e15c .