Notifications
You must be signed in to change notification settings - Fork 1
/
devanoor_complete.m
146 lines (124 loc) · 4.29 KB
/
devanoor_complete.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
clear
clc
% Deleting pervious files
delete ('temp.inp','temp1.$$$','temp2.$$$','temp.txt','temp.out','hyd.out');
% Input Files
inpname='Devanoor_10DMA_new_pattern';
% Output file
outfile = 'hyd.out';
d=epanet([inpname,'.inp']);
% Setting Simulation duration and settings
d.setTimeSimulationDuration(86400);
d.setTimeHydraulicStep(600);
d.setTimeReportingStep(3600);
index = d.LinkIndex;
valves_index = d.LinkValveIndex;
tanks = d.NodeTankIndex;
% Setting the setting-read file
settings = xlsread('Settings-all_new_pattern.xls');
% Simulate all times
d.solveCompleteHydraulics;
%d.solveCompleteQuality;
% Report generation
d.saveHydraulicsOutputReportingFile
d.setReportFormatReset
d.setReport('FILE TestReport.txt');
d.setReport('PAGESIZE 0')
d.setReport('NODES ALL')%/ALL/node1 node2
d.setReport('LINKS ALL')%/ALL/link1 link2
%d.setReport('PRESSURE PRECISION 1')
%d.setReport('PRESSURE ABOVE 20')
d.setReport('STATUS YES')%YES/NO/FULL
d.setReport('SUMMARY YES')%YES/NO
d.setReport('MESSAGES YES')%YES/NO
d.setReport('ENERGY YES')%YES/NO
%Nodes parameters
%YES/NO/BELOW/ABOVE/PRECISION
d.setReport('ELEVATION YES')
d.setReport('DEMAND YES')
d.setReport('HEAD YES')
d.setReport('PRESSURE YES')
%d.setReport('QUALITY YES') % bug.
%Links parameters
%BELOW/ABOVE/PRECISION
% d.setReport('LENGTH YES')
% d.setReport('DIAMETER YES')
d.setReport('FLOW YES')
% d.setReport('LENGTH YES')
d.setReport('VELOCITY YES')
d.setReport('HEADLOSS YES')
% d.setReport('QUALITY PRECISION 1')
d.setReport('STATUS YES')
d.setReport('SETTING YES')
% d.setReport('REACTION YES')
% d.setReport('F-FACTOR YES')
%Write the report to file
% d.writeReport
% movefile('TestReport.txt',[pwd,'/RESULTS/','TestReport-8:00.txt']);
% Runs hydraulics Step-by-step
d.openHydraulicAnalysis;
d.initializeHydraulicAnalysis;
% Variable initialisation
tstep=1; P=[];T=[]; D=[]; H=[];F=[];E=[]; TM=[];TH=[];VF=[];temp=[];
hour_counter=1;
% Valve initialisation
[valves_setting] = d.getLinkInitialSetting;
valves_setting = repmat(valves_setting,[12,1]);
for counter = 1:size(settings,1)
% Valve values from settings are copied onto the valve_setting
valves_setting(counter,valves_index) =settings(counter,:);
end
%setting the valves for the 0th hour
d.setLinkSettings(valves_setting(hour_counter,:));
% %checking the valve settings before calculation
[temp] = d.getLinkSettings;
% Simulation loop
while (tstep>0) %&& hour_counter<12 )
t=d.runHydraulicAnalysis;
P=[P; d.getNodePressure]; %#ok<AGROW>
D=[D; d.getNodeActualDemand]; %#ok<AGROW>
H=[H; d.getNodeHydaulicHead];
TM = [TM; d.getNodeTankMinimumWaterLevel];
E=[E; d.getNodeElevations];
TH = [TH; H(end,48:end) - E(end,48:end) - TM(end,48:end)];
F=[F; d.getLinkFlows];
VF = [VF; F(end,48:end)];
T=[T; t];
tstep=d.nextHydraulicAnalysisStep;
if ((t > 0 && t < 86400) && ~rem(t,3600))
hour_counter = hour_counter+1;
% Setting valve values
d.setLinkSettings(valves_setting(hour_counter,:));
% checking the valve settings- for testing purpose
temp = [temp; d.getLinkSettings];
end
end
% Tank Percentages
Perc = [];
Perc(:,1) = fillperc(TH(:,1),14.5,1000000);
Perc(:,2) = fillperc(TH(:,2),14.5,1000000);
Perc(:,3) = fillperc(TH(:,3),17,1500000);
Perc(:,4) = fillperc(TH(:,4),10.3,500000);
Perc(:,5) = fillperc(TH(:,5),10.3,500000);
Perc(:,6) = fillperc(TH(:,6),14.5,1000000);
Perc(:,7) = fillperc(TH(:,7),10.3,500000);
Perc(:,8) = fillperc(TH(:,8),7.3,250000);
Perc(:,9) = fillperc(TH(:,9),14.5,1000000);
Perc(:,10) = fillperc(TH(:,10),17,1500000);
Perc(:,11) = fillperc(TH(:,11),14.5,1000000);
%createfigure(T/3600, Perc(:,1:11), VF(:,1:12));
% Plot the tank levels
figure(1)
subplot(2,1,1);
plot(T/3600,Perc(:,1:end),'DisplayName','Perc(:,1:11)','YDataSource','Perc(:,1:11)');
% Plot the Valve Flow
%figure(2)
subplot(2,1,2);
plot(T/3600,VF(:,1:end),'DisplayName','VF(:,1:12)','YDataSource','VF(:,1:12)');
% d.writeReport
% movefile('TestReport.txt',[pwd,'/RESULTS/','TestReport-devanoor.txt']);
d.closeHydraulicAnalysis;
% d.saveHydraulicFile(outfile);
% d.useHydraulicFile(outfile);
% d.saveInputFile([pwd,'/RESULTS/','hyd.inp']);
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%