import socket
import time
import can
import cantools
from pprint import pprint
import os
from enum import Enum
bus1 = can.Bus(channel="can0", interface='socketcan')
def main():
inverter_ready = False
inverter_hv_on = False # quit dc on
inverter_enabled = False # quit inverter on
db = cantools.database.load_file("hytech_dbc.dbc")
setpoint = db.get_message_by_name("MC1_SETPOINTS_COMMAND")
empty_msg = setpoint.encode({'negative_torque_limit': 0, 'positive_torque_limit': 0, 'speed_setpoint_rpm': 0, 'remove_error': 1, 'driver_enable': 0, 'hv_enable': 0, 'inverter_enable': 0})
reset_error_msg = setpoint.encode({'negative_torque_limit': 0, 'positive_torque_limit': 0, 'speed_setpoint_rpm': 0, 'remove_error': 1, 'driver_enable': 0, 'hv_enable': 0, 'inverter_enable': 0})
hv_on_msg = setpoint.encode({'negative_torque_limit': 0, 'positive_torque_limit': 0, 'speed_setpoint_rpm': 0, 'remove_error': 0, 'driver_enable': 0, 'hv_enable': 1, 'inverter_enable': 0})
inverter_on_msg = setpoint.encode({'negative_torque_limit': 0, 'positive_torque_limit': 0, 'speed_setpoint_rpm': 0, 'remove_error': 0, 'driver_enable': 1, 'hv_enable': 1, 'inverter_enable': 1})
rpm_msg = setpoint.encode({'negative_torque_limit': -2, 'positive_torque_limit': 2, 'speed_setpoint_rpm': 100, 'remove_error': 0, 'driver_enable': 1, 'hv_enable': 1, 'inverter_enable': 1})
current_rpm = 0
# torq_msg = setpoint.encode({'negative_torque_limit': -2, 'positive_torque_limit': 2, 'speed_setpoint_rpm': 100, 'remove_error': 0, 'driver_enable': 1, 'hv_enable': 1, 'inverter_enable': 1})
error_reset = False
while(1):
if(not error_reset):
try:
msg = can.Message(arbitration_id=setpoint.frame_id, is_extended_id=False, data = reset_error_msg)
bus1.send(msg)
except can.CanError:
print("Message NOT sent! Please verify can0 is working first")
error_reset = True
if(inverter_ready and inverter_hv_on and inverter_enabled):
print("inverter enabled yippee, attempting cmd")
try:
if(current_rpm < 2000):
msg = can.Message(arbitration_id=setpoint.frame_id, is_extended_id=False, data=rpm_msg)
else:
msg = can.Message(arbitration_id=setpoint.frame_id, is_extended_id=False, data=empty_msg)
bus1.send(msg)
except can.CanError:
print("Message NOT sent! Please verify can0 is working first")
elif((not inverter_hv_on) and (inverter_ready) and (not inverter_enabled)):
print(inverter_hv_on)
print(inverter_ready)
print(inverter_enabled)
print("inverter not ready, attempting hv init")
try:
msg = can.Message(arbitration_id=setpoint.frame_id, is_extended_id=False, data=hv_on_msg)
bus1.send(msg)
except can.CanError:
print("Message NOT sent! Please verify can0 is working first")
elif(inverter_hv_on and inverter_ready and (not inverter_enabled) ):
print("inverter ready and hv on but inverter not enabled")
try:
msg = can.Message(arbitration_id=setpoint.frame_id, is_extended_id=False, data=inverter_on_msg)
bus1.send(msg)
except can.CanError:
print("Message NOT sent! Please verify can0 is working first")
elif((not inverter_hv_on) and (not inverter_ready) and (not inverter_enabled)):
print("first msg")
try:
msg = can.Message(arbitration_id=setpoint.frame_id, is_extended_id=False, data=empty_msg)
bus1.send(msg)
except can.CanError:
print("Message NOT sent! Please verify can0 is working first")
rcvd_message = bus1.recv(timeout=0.1)
if(rcvd_message):
try:
decoded_message = db.decode_message(rcvd_message.arbitration_id, rcvd_message.data)
msg_info = db.get_message_by_frame_id(rcvd_message.arbitration_id)
# print(f"Decoded Message: {decoded_message}")
if( (msg_info.name.lower() == "mc1_status")):
inverter_ready = decoded_message["system_ready"]
inverter_hv_on = decoded_message["quit_dc_on"]
inverter_enabled = decoded_message["quit_inverter_on"]
current_rpm = abs(decoded_message["speed_rpm"])
except KeyError:
print(f"Message ID {rcvd_message.arbitration_id} not found in the DBC.")
except Exception as e:
print(f"Error decoding message: {e}")
time.sleep(0.02)
if __name__ == "__main__":
main()