Investigate the use of the DRV5053 sensor #17
Comments
The inverted polarity shouldn't be an issue, but I'm wondering about the response time. Do you have a rough idea of what the expected (reliable) sampling rate would be given the small measurement tolerance? |
The SS495A datasheets state a response time of 3 μs and the DRV state a typical of 13 μs and a max of 25 μs. I believe either one is appropriate. In terms of sampling rate I'm not sure, but the DRV sensor has a much more detailed application note around designing RC filters to achieve an appropriate bandwidth. Ultimately it comes down to the filament, it would be interesting to see what sort of frequencies the variations in filament occur at. Can you detect mains switching frequency in the diameter of filament? Of course it wouldn't be at the same frequency unless your feedrate is the same as the original extruder.... Something to keep me awake at night... |
The reduced response of the DRV5053 is certainly an issue. We're measuring very small differences in movements of the magnet and the chart makes it look like the SS495A has more than four times the full range. |
The sensors are closer to one another than you might think, in terms of linear range the DRV sensor beats the SS495 (only by 6 mT but there we are) Because we are going through a calibration routine I suspect it won't matter, and because we are in a fairly loosely coupled system (lets face it the extruder of a printer can't respond at the rates we are talking about here) I suspect it's all in the weeds.
|
The sensitivity value of the SS495A is more than three times that of the DRV5030A. That’s a lot. We won’t be affected by the limit, we’re working with a small magnet. Our interest is how much the signal changes for a small change in mT. |
I must admit that as a software guy, the physics and electrical engineering behind the final determination of whether this change will be a problem is increasingly beyond my expertise. However, I would like to offer two things. First, maybe it would be worth reaching out to Tom to see if he had considered using this alternative sensor, perhaps he has some knowledge or did some tests on this. Second, it might be worth considering this change in terms of the maximum sensitivity per time unit, rather than overall sensitivity or maximum frequency of a reliable sample in ideal conditions. If we take this approach, it would be more practical to be able to calculate the maximum detectable deviation for a given feedrate, and we can also determine whether this detectable deviation is within an acceptable spec over a number of observations. This is very much related to what I had in mind for #5. |
You say we are working with a small magnet, they are quite potent and are quite close to the sensor. Do you know for a fact that we are within the linear region for the sensor? |
There are also other SKUs of the DRV5053, including ones with significantly higher sensitivity, in the realm of 90 mV/mT, but they become saturated at much lower levels. |
It would be interesting to see what the raw values shake out to be during the calibration process. |
Maximum sensitivity per time unit would be a function of sensitivity and output delay time. In a device that A bigger cost saving might be to use a RPi pico ($4) instead of the custom PCB. Faster, on-board data storage, serial IO as well as I2C, available without custom manufacture. |
While this is true, this is both a substantial change to the hardware design and also a total redo of the firmware (including a shift to a different development environment and language). I'm not sure whether this is a good idea or not at this stage. There is also the potential for a shortfall in available volume of parts. All of this is a useful discussion, so let's keep hashing this out until we arrive at a practical answer. The goal is to keep the cost as low as possible, but there is an obvious multi-objective trade-off between cost, manufacturability/availability, and utility. It is totally unclear to me what the impact is on these objectives with each of these proposed changes right now. |
That's a fact. Probably better as a fork. It does work a treat, though 😁. |
In place of the SS495A sensor we could instead use a comparable TI part, namely the DRV5053. Pros of the DRV5053 are it is significantly less expensive (less than half the cost) for a similar spec part, they are pin compatible.
I have prototyped the circuit on a breadboard and tested side by side the SS495A sensor and the DRV5053, below is the waveform generated by the two sensors, the DRV is on the left and the SS495A is on the right, as you can see the output is much higher from the SS495.
The polarity is reversed between the sensors, but in theory you just have to install the magnet in the other way around.
I checked it using a magnet on which I marked a side and offered it up to the 2 sensors.
Do people think the lower response and reversal of polarity will be an issue?
Below is the breadboard set up for reference.