183 lines (146 loc) · 8.01 KB
/
Program.cs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
using System;
using System.Collections.Generic;
using System.Data;
using System.Linq;
using System.Text;
using System.Threading;
using System.Threading.Tasks;
namespace CopyTagsRawDataFromGEProficyToOsisoftPI
{
class Program
{
private static readonly HistDA histDA = new HistDA();
private static readonly PIDA piDA = new PIDA();
static void Main(string[] args)
{
Console.WriteLine(" +++ BorsodChem Zrt. +++ ");
Console.WriteLine("Copy Tag Raw values from GE Proficy MES to OSIsoft PI");
Console.WriteLine("At this point this project is for test purposes only!");
Console.WriteLine("");
StartDataProcessFromProficyHistorian();
//DeleteValuesFromPISystem();
Console.ReadKey();
}
private static void StartDataProcessFromProficyHistorian()
{
//string piTag = "BC.M.MANUAL_TEST.PV"; //Float32 test Tag in PI: BC.M.MANUAL_TEST.PV
//string piTag = "BC.M.MANUAL_TEST2.PV"; //String test Tag in PI: BC.M.MANUAL_TEST2.PV
//string piTag = "BC.M.MANUAL_TEST3.PV"; //Digital test Tag in PI: BC.M.MANUAL_TEST3.PV -> for motors/pumps/valves open-close positions
//string piTag = "BC.M.MANUAL_TEST4.PV"; //Int16 test Tag in PI: BC.M.MANUAL_TEST4.PV
//Data Type: GE Proficy -> Osisoft PI
//string tagName = "BC.TDI1.FIC3401.PV"; // Single Float -> Float32
//string tagName = "BC.TDI1.FIC3401.MODE"; // Variable String -> String
//string tagName = "BC.HCLCONV.FIC1020.MODE"; // (python script) -> String
//string tagName = "BC.TDI1.P3774BFUT.PV"; // Single Float -> Digital (running signal: 0;1)
//string tagName = "BC.TDI2.UP6901A.PV"; // Single Integer -> Digital (running signal: 0;2 -> 0 is not running always)
//string tagName = "BC.HCLCONV.XV1700B.PV"; // Single Float -> Digital (running signal: -1;0 -> 0 is not running always)
string[] tagNames = { "BC.M.PITEST1.PV", "BC.M.PITEST2.PV", "BC.M.PITEST3.PV" };
//string[] tagNames = { "BC.TDI1.FIC3401.PV" };
var startDate = new DateTime(2022, 01, 01, 00, 00, 00); // give a correct start date
//var startDate = DateTime.Now.AddHours(-12);
//var startDate = DateTime.Now.AddDays(-120);
//var endDate = new DateTime(2022, 01, 01, 00, 00, 00); // give a correct end date
var endDate = DateTime.Now;
foreach (string tagName in tagNames)
{
Console.WriteLine("");
Console.WriteLine("Tag: " + tagName);
Console.WriteLine("Query start date: " + startDate.ToString("yyyy.MM.dd. HH:mm:ss"));
var rawData = ProcessDataFromProficy(tagName, startDate, endDate);
var dataToImport = rawData.AsEnumerable()
.Where(r => r.Field<DateTime>("TimeStamp") <= endDate)
//.Where(r => r.Field<string>("Quality") == "Good")
.Select
(r => new
{
Value = r.Field<string>("Value"),
Quality = r.Field<string>("Quality"),
TimeStamp = r.Field<DateTime>("TimeStamp").ToLocalTime().IsDaylightSavingTime() ?
r.Field<DateTime>("TimeStamp").ToLocalTime() :
r.Field<DateTime>("TimeStamp").ToLocalTime().AddHours(-1) //UTC -> CET - CEST correction!!!
}).ToList();
if (dataToImport.Count > 0)
{
Console.WriteLine("Start inserting values into AF database!");
//bool result = piDA.UpdateTagValues(piTag, Extensions.ConvertToDataTable(dataToImport), true); //for TEST Tags, MUST BE added manually
//bool result = piDA.UpdateTagValues(tagName, Extensions.ConvertToDataTable(dataToImport), false);
//bool result = piDA.InsertTagValues(piTag, Extensions.ConvertToDataTable(dataToImport), false);
bool result = piDA.InsertTagValues(tagName, Extensions.ConvertToDataTable(dataToImport), false);
if (result)
{
Console.WriteLine("Insert is finished!");
}
}
else
{
Console.WriteLine("No data to be written! Check your query!");
}
}
Console.WriteLine("Finished all tags.");
}
private static DataTable ProcessDataFromProficy(string tagName, DateTime startDate, DateTime endDate)
{
int rowCount = 0;
var tagRawData = new DataTable();
Console.WriteLine();
Console.WriteLine("Start");
Console.WriteLine();
if (!histDA.IsConnected)
{
histDA.Connect();
do
{
var tagRawDataPart = histDA.QueryRawTagValues(startDate, tagName, out string dataType);
startDate = tagRawDataPart.AsEnumerable()
.Max(r => r.Field<DateTime>("TimeStamp"));
tagRawData.Merge(tagRawDataPart);
rowCount = tagRawData.Rows.Count;
Console.Write("\rQuery progress: {0} row(s)", rowCount);
//Thread.Sleep(5000);
}
while (rowCount % 500000 == 0 && rowCount > 0 && rowCount < 16500000 && startDate < endDate);
var badValuesCount = tagRawData.AsEnumerable()
.Count(r => r.Field<string>("Quality") != "Good");
var minDate = tagRawData.AsEnumerable()
.Min(r => r.Field<DateTime>("TimeStamp"));
var maxDate = tagRawData.AsEnumerable()
.Max(r => r.Field<DateTime>("TimeStamp"));
Console.WriteLine();
Console.WriteLine();
Console.WriteLine("Done!");
Console.WriteLine("Out of this BAD quality values: " + badValuesCount);
Console.WriteLine("Min date (UTC): " + minDate.ToString("yyyy.MM.dd. HH:mm:ss"));
Console.WriteLine("Max date (UTC): " + maxDate.ToString("yyyy.MM.dd. HH:mm:ss"));
Console.WriteLine("!!! TimeStamp is in UTC time, just like how GE Proficy stores values in its own database! Date is converted to local during the next step!");
}
return tagRawData;
}
private static void DeleteValuesFromPISystem()
{
string piTag = "BC.M.MANUAL_TEST3.PV"; //Float32 test Tag in PI: BC.M.MANUAL_TEST.PV
Console.WriteLine("Delete method started for tag: " + piTag);
var startDate = new DateTime(2021, 01, 18, 12, 52, 50, DateTimeKind.Local); // give a correct start date
var endDate = new DateTime(2022, 01, 19, 13, 52, 50, DateTimeKind.Local); // give a correct end date
Console.WriteLine("Delete start: " + startDate.ToString("yyyy.MM.dd. HH:mm:ss"));
Console.WriteLine("Delete end: " + endDate.ToString("yyyy.MM.dd. HH:mm:ss"));
var values = piDA.QueryTagRawValues(piTag, startDate, endDate);
//var values = piDA.QueryTagRawValues(piTag, startDate, 1, true);
if (values.Count != 0)
{
var result = piDA.DeleteTagValues(values);
if (result)
{
Console.WriteLine(values.Count + " value(s) are deleted!");
}
else
{
Console.WriteLine("No values are deleted!");
}
}
else
{
Console.WriteLine("No data can be deleted for the selected interval!");
}
}
}
}