Notifications
You must be signed in to change notification settings - Fork 14
/
Copy pathENTITY-SENSOR-MIB
440 lines (376 loc) · 15.8 KB
/
ENTITY-SENSOR-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
ENTITY-SENSOR-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, Unsigned32, mib-2
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION, TimeStamp
FROM SNMPv2-TC
entPhysicalIndex, entityPhysicalGroup
FROM ENTITY-MIB
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB;
entitySensorMIB MODULE-IDENTITY
LAST-UPDATED "200212160000Z"
ORGANIZATION "IETF Entity MIB Working Group"
CONTACT-INFO
" Andy Bierman
Cisco Systems, Inc.
Tel: +1 408-527-3711
E-mail: abierman@cisco.com
Postal: 170 West Tasman Drive
San Jose, CA USA 95134
Dan Romascanu
Avaya Inc.
Tel: +972-3-645-8414
Email: dromasca@avaya.com
Postal: Atidim technology Park, Bldg. #3
Tel Aviv, Israel, 61131
K.C. Norseth
L-3 Communications
Tel: +1 801-594-2809
Email: kenyon.c.norseth@L-3com.com
Postal: 640 N. 2200 West.
Salt Lake City, Utah 84116-0850
Send comments to <entmib@ietf.org>
Mailing list subscription info:
http://www.ietf.org/mailman/listinfo/entmib "
DESCRIPTION
"This module defines Entity MIB extensions for physical
sensors.
Copyright (C) The Internet Society (2002). This version
of this MIB module is part of RFC 3433; see the RFC
itself for full legal notices."
REVISION "200212160000Z"
DESCRIPTION
"Initial version of the Entity Sensor MIB module, published
as RFC 3433."
::= { mib-2 99 }
entitySensorObjects OBJECT IDENTIFIER
::= { entitySensorMIB 1 }
-- entitySensorNotifications OBJECT IDENTIFIER
-- ::= { entitySensorMIB 2 }
entitySensorConformance OBJECT IDENTIFIER
::= { entitySensorMIB 3 }
--
-- Textual Conventions
--
EntitySensorDataType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An object using this data type represents the Entity Sensor
measurement data type associated with a physical sensor
value. The actual data units are determined by examining an
object of this type together with the associated
EntitySensorDataScale object.
An object of this type SHOULD be defined together with
objects of type EntitySensorDataScale and
EntitySensorPrecision. Together, associated objects of
these three types are used to identify the semantics of an
object of type EntitySensorValue.
Valid values are:
other(1): a measure other than those listed below
unknown(2): unknown measurement, or arbitrary,
relative numbers
voltsAC(3): electric potential
voltsDC(4): electric potential
amperes(5): electric current
watts(6): power
hertz(7): frequency
celsius(8): temperature
percentRH(9): percent relative humidity
rpm(10): shaft revolutions per minute
cmm(11),: cubic meters per minute (airflow)
truthvalue(12): value takes { true(1), false(2) }
"
SYNTAX INTEGER {
other(1),
unknown(2),
voltsAC(3),
voltsDC(4),
amperes(5),
watts(6),
hertz(7),
celsius(8),
percentRH(9),
rpm(10),
cmm(11),
truthvalue(12)
}
EntitySensorDataScale ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An object using this data type represents a data scaling
factor, represented with an International System of Units
(SI) prefix. The actual data units are determined by
examining an object of this type together with the
associated EntitySensorDataType object.
An object of this type SHOULD be defined together with
objects of type EntitySensorDataType and
EntitySensorPrecision. Together, associated objects of
these three types are used to identify the semantics of an
object of type EntitySensorValue."
REFERENCE
"The International System of Units (SI),
National Institute of Standards and Technology,
Spec. Publ. 330, August 1991."
SYNTAX INTEGER {
yocto(1), -- 10^-24
zepto(2), -- 10^-21
atto(3), -- 10^-18
femto(4), -- 10^-15
pico(5), -- 10^-12
nano(6), -- 10^-9
micro(7), -- 10^-6
milli(8), -- 10^-3
units(9), -- 10^0
kilo(10), -- 10^3
mega(11), -- 10^6
giga(12), -- 10^9
tera(13), -- 10^12
exa(14), -- 10^15
peta(15), -- 10^18
zetta(16), -- 10^21
yotta(17) -- 10^24
}
EntitySensorPrecision ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An object using this data type represents a sensor
precision range.
An object of this type SHOULD be defined together with
objects of type EntitySensorDataType and
EntitySensorDataScale. Together, associated objects of
these three types are used to identify the semantics of an
object of type EntitySensorValue.
If an object of this type contains a value in the range 1 to
9, it represents the number of decimal places in the
fractional part of an associated EntitySensorValue fixed-
point number.
If an object of this type contains a value in the range -8
to -1, it represents the number of accurate digits in the
associated EntitySensorValue fixed-point number.
The value zero indicates the associated EntitySensorValue
object is not a fixed-point number.
Agent implementors must choose a value for the associated
EntitySensorPrecision object so that the precision and
accuracy of the associated EntitySensorValue object is
correctly indicated.
For example, a physical entity representing a temperature
sensor that can measure 0 degrees to 100 degrees C in 0.1
degree increments, +/- 0.05 degrees, would have an
EntitySensorPrecision value of '1', an EntitySensorDataScale
value of 'units(9)', and an EntitySensorValue ranging from
'0' to '1000'. The EntitySensorValue would be interpreted
as 'degrees C * 10'."
SYNTAX Integer32 (-8..9)
EntitySensorValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An object using this data type represents an Entity Sensor
value.
An object of this type SHOULD be defined together with
objects of type EntitySensorDataType, EntitySensorDataScale
and EntitySensorPrecision. Together, associated objects of
those three types are used to identify the semantics of an
object of this data type.
The semantics of an object using this data type are
determined by the value of the associated
EntitySensorDataType object.
If the associated EntitySensorDataType object is equal to
'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6),
'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of
this type MUST contain a fixed point number ranging from
-999,999,999 to +999,999,999. The value -1000000000
indicates an underflow error. The value +1000000000
indicates an overflow error. The EntitySensorPrecision
indicates how many fractional digits are represented in the
associated EntitySensorValue object.
If the associated EntitySensorDataType object is equal to
'percentRH(9)', then an object of this type MUST contain a
number ranging from 0 to 100.
If the associated EntitySensorDataType object is equal to
'rpm(10)', then an object of this type MUST contain a number
ranging from -999,999,999 to +999,999,999.
If the associated EntitySensorDataType object is equal to
'truthvalue(12)', then an object of this type MUST contain
either the value 'true(1)' or the value 'false(2)'.
If the associated EntitySensorDataType object is equal to
'other(1)' or unknown(2)', then an object of this type MUST
contain a number ranging from -1000000000 to 1000000000."
SYNTAX Integer32 (-1000000000..1000000000)
EntitySensorStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An object using this data type represents the operational
status of a physical sensor.
The value 'ok(1)' indicates that the agent can obtain the
sensor value.
The value 'unavailable(2)' indicates that the agent
presently cannot obtain the sensor value.
The value 'nonoperational(3)' indicates that the agent
believes the sensor is broken. The sensor could have a hard
failure (disconnected wire), or a soft failure such as out-
of-range, jittery, or wildly fluctuating readings."
SYNTAX INTEGER {
ok(1),
unavailable(2),
nonoperational(3)
}
--
-- Entity Sensor Table
--
entPhySensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF EntPhySensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per physical sensor represented
by an associated row in the entPhysicalTable."
::= { entitySensorObjects 1 }
entPhySensorEntry OBJECT-TYPE
SYNTAX EntPhySensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular physical sensor.
An entry in this table describes the present reading of a
sensor, the measurement units and scale, and sensor
operational status.
Entries are created in this table by the agent. An entry
for each physical sensor SHOULD be created at the same time
as the associated entPhysicalEntry. An entry SHOULD be
destroyed if the associated entPhysicalEntry is destroyed."
INDEX { entPhysicalIndex } -- SPARSE-AUGMENTS
::= { entPhySensorTable 1 }
EntPhySensorEntry ::= SEQUENCE {
entPhySensorType EntitySensorDataType,
entPhySensorScale EntitySensorDataScale,
entPhySensorPrecision EntitySensorPrecision,
entPhySensorValue EntitySensorValue,
entPhySensorOperStatus EntitySensorStatus,
entPhySensorUnitsDisplay SnmpAdminString,
entPhySensorValueTimeStamp TimeStamp,
entPhySensorValueUpdateRate Unsigned32
}
entPhySensorType OBJECT-TYPE
SYNTAX EntitySensorDataType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of data returned by the associated
entPhySensorValue object.
This object SHOULD be set by the agent during entry
creation, and the value SHOULD NOT change during operation."
::= { entPhySensorEntry 1 }
entPhySensorScale OBJECT-TYPE
SYNTAX EntitySensorDataScale
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The exponent to apply to values returned by the associated
entPhySensorValue object.
This object SHOULD be set by the agent during entry
creation, and the value SHOULD NOT change during operation."
::= { entPhySensorEntry 2 }
entPhySensorPrecision OBJECT-TYPE
SYNTAX EntitySensorPrecision
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of decimal places of precision in fixed-point
sensor values returned by the associated entPhySensorValue
object.
This object SHOULD be set to '0' when the associated
entPhySensorType value is not a fixed-point type: e.g.,
'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.
This object SHOULD be set by the agent during entry
creation, and the value SHOULD NOT change during operation."
::= { entPhySensorEntry 3 }
entPhySensorValue OBJECT-TYPE
SYNTAX EntitySensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recent measurement obtained by the agent for this
sensor.
To correctly interpret the value of this object, the
associated entPhySensorType, entPhySensorScale, and
entPhySensorPrecision objects must also be examined."
::= { entPhySensorEntry 4 }
entPhySensorOperStatus OBJECT-TYPE
SYNTAX EntitySensorStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational status of the sensor."
::= { entPhySensorEntry 5 }
entPhySensorUnitsDisplay OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual description of the data units that should be used
in the display of entPhySensorValue."
::= { entPhySensorEntry 6 }
entPhySensorValueTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the status and/or value
of this sensor was last obtained by the agent."
::= { entPhySensorEntry 7 }
entPhySensorValueUpdateRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of the frequency that the agent updates the
associated entPhySensorValue object, representing in
milliseconds.
The value zero indicates:
- the sensor value is updated on demand (e.g.,
when polled by the agent for a get-request),
- the sensor value is updated when the sensor
value changes (event-driven),
- the agent does not know the update rate.
"
::= { entPhySensorEntry 8 }
--
-- Conformance Section
--
entitySensorCompliances OBJECT IDENTIFIER
::= { entitySensorConformance 1 }
entitySensorGroups OBJECT IDENTIFIER
::= { entitySensorConformance 2 }
entitySensorCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the Entity
Sensor MIB module."
MODULE -- this module
MANDATORY-GROUPS { entitySensorValueGroup }
MODULE ENTITY-MIB
MANDATORY-GROUPS { entityPhysicalGroup }
::= { entitySensorCompliances 1 }
-- Object Groups
entitySensorValueGroup OBJECT-GROUP
OBJECTS {
entPhySensorType,
entPhySensorScale,
entPhySensorPrecision,
entPhySensorValue,
entPhySensorOperStatus,
entPhySensorUnitsDisplay,
entPhySensorValueTimeStamp,
entPhySensorValueUpdateRate
}
STATUS current
DESCRIPTION
"A collection of objects representing physical entity sensor
information."
::= { entitySensorGroups 1 }