Panasonic DKE/JKE/NKE heatpump control (DKE remote control P/N A75C2616 etc)
*/
#ifndef PanasonicHeatpumpIR_h
#define PanasonicHeatpumpIR_h
#include <HeatpumpIR.h>
// Panasonic DKE, JKE & NKE timing constants (DKE remote control P/N A75C2616)
#define PANASONIC_AIRCON2_HDR_MARK 3500
#define PANASONIC_AIRCON2_HDR_SPACE 1800
#define PANASONIC_AIRCON2_BIT_MARK 420
#define PANASONIC_AIRCON2_ONE_SPACE 1350
#define PANASONIC_AIRCON2_ZERO_SPACE 470
#define PANASONIC_AIRCON2_MSG_SPACE 10000
// Panasonic DKE, JNE & NKE codes
#define PANASONIC_AIRCON2_MODE_AUTO 0x00 // Operating mode
#define PANASONIC_AIRCON2_MODE_HEAT 0x40
#define PANASONIC_AIRCON2_MODE_COOL 0x30
#define PANASONIC_AIRCON2_MODE_DRY 0x20
#define PANASONIC_AIRCON2_MODE_FAN 0x60
#define PANASONIC_AIRCON2_MODE_OFF 0x00 // Power OFF
#define PANASONIC_AIRCON2_MODE_ON 0x01
#define PANASONIC_AIRCON2_TIMER_CNL 0x08
#define PANASONIC_AIRCON2_FAN_AUTO 0xA0 // Fan speed
#define PANASONIC_AIRCON2_FAN1 0x30
#define PANASONIC_AIRCON2_FAN2 0x40
#define PANASONIC_AIRCON2_FAN3 0x50
#define PANASONIC_AIRCON2_FAN4 0x60
#define PANASONIC_AIRCON2_FAN5 0x70
#define PANASONIC_AIRCON2_VS_AUTO 0x0F // Vertical swing
#define PANASONIC_AIRCON2_VS_UP 0x01
#define PANASONIC_AIRCON2_VS_MUP 0x02
#define PANASONIC_AIRCON2_VS_MIDDLE 0x03
#define PANASONIC_AIRCON2_VS_MDOWN 0x04
#define PANASONIC_AIRCON2_VS_DOWN 0x05
#define PANASONIC_AIRCON2_HS_AUTO 0x0D // Horizontal swing
#define PANASONIC_AIRCON2_HS_MIDDLE 0x06
#define PANASONIC_AIRCON2_HS_LEFT 0x09
#define PANASONIC_AIRCON2_HS_MLEFT 0x0A
#define PANASONIC_AIRCON2_HS_MRIGHT 0x0B
#define PANASONIC_AIRCON2_HS_RIGHT 0x0C
#define PANASONIC_AIRCON2_QUIET 0x01 // Quiet setting
#define PANASONIC_AIRCON2_POWERFUL 0x20 // Powerful setting
// Panasonic model codes
#define PANASONIC_DKE 0
#define PANASONIC_JKE 1
#define PANASONIC_NKE 2
#define PANASONIC_LKE 3
class PanasonicHeatpumpIR : public HeatpumpIR
{
protected: // Cannot create generic Panasonic heatpump instances
PanasonicHeatpumpIR();
uint8_t _panasonicModel; // Tells whether this is DKE, NKE or JKE (or other supported model...)
public:
void send(IRSender& IR, uint8_t powerModeCmd, uint8_t operatingModeCmd, uint8_t fanSpeedCmd, uint8_t temperatureCmd, uint8_t swingVCmd, uint8_t swingHCmd);
void send(IRSender& IR, uint8_t powerModeCmd, uint8_t operatingModeCmd, uint8_t fanSpeedCmd, uint8_t temperatureCmd, uint8_t swingVCmd, uint8_t swingHCmd, bool powerfulCmd, bool quietCmd);
private:
void sendPanasonic(IRSender& IR, uint8_t operatingMode, uint8_t fanSpeed, uint8_t temperature, uint8_t swingV, uint8_t swingH, uint8_t profile);
};
class PanasonicDKEHeatpumpIR : public PanasonicHeatpumpIR
{
public:
PanasonicDKEHeatpumpIR();
};
class PanasonicJKEHeatpumpIR : public PanasonicHeatpumpIR
{
public:
PanasonicJKEHeatpumpIR();
};
class PanasonicNKEHeatpumpIR : public PanasonicHeatpumpIR
{
public:
PanasonicNKEHeatpumpIR();
};
class PanasonicLKEHeatpumpIR : public PanasonicHeatpumpIR
{
public:
PanasonicLKEHeatpumpIR();
};
#endif