v1.13
Version 1.13 release notes
- Fixed bug in axially-aligned modular-beam forward projector which was causing incorrect values when the detector had a significantly large rotation around the optical axis
- Improvements to parameter_sweep algorithm
- Added "consistency_cost" function to help with geometric calibration
- Added more examples to demo script: d12_geometric_calibration.py including examples of using items 2 and 3, above
- Added more features to logging utility to control the amount of screen output from none, to detailed debugging logs
- Added a new demo struct, d33_reducingConeBeamArtifacts.py
- Relaxed required cmake minimum version and made some changes to the build process
- Fixed bug in makeAttenuationRadiographs
- Added to documentation