Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathparameters_and_constants.py
161 lines (116 loc) · 6.31 KB
/
parameters_and_constants.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
# -*- coding: utf-8 -*-
"""
Created on Wed Feb 22 15:28:39 2023
@author: jkalanger
"""
import pandas as pd
import numpy as np
def parameters_and_constants(p_gross=-136000,cost_level='low_cost',data='CMEMS'):
if data == 'HYCOM':
## Setup for HYCOM seawater resource data download
glb = 'GLBu0.08'
horizontal_stride = 3
time_origin = '2000-01-01 00:00:00'
year = 2011
date_start = '2011-01-01 00:00:00'
date_end = '2011-12-31 21:00:00'
time_stride = 1
# depths = [0,2,4,6,8,10,12,15,20,25,30,35,40,45,50,60,70,80,90,100,125,150,200,250,300,350,400,500,600,700,800,900,1000,1250,1500,2000,2500,3000,4000,5000]
else:
## Setup for CMEMS data download using motu
time_origin = '1950-01-01 00:00:00'
year = 2020
date_start = '2020-01-01 00:00:00'
date_end = '2020-12-31 21:00:00'
t_resolution = '24H'
## Physical properties
rho_NH3 = 625 # density of ammonia in kg/m3
rho_WW = 1024 # density of warm seawater in kg/m3
rho_CW = 1027 # density of cold seawater in kg/m3
cp_water = 4.0 # specific heat capacity of seawater in kJ/kgK
fluid_properties = [rho_NH3,rho_WW,rho_CW,cp_water]
roughness_pipe = 0.03 #053 # roughness of pipe in m
if cost_level == 'low_cost':
rho_pipe = 995 # density of HDPE pipe in kg/m3
elif cost_level == 'high_cost':
rho_pipe = 1016 # density of FRP sandwich pipe in kg/m3
else:
raise ValueError('Invalid cost level. Valid inputs are "low_cost" and "high_cost"')
pipe_material = [rho_pipe,roughness_pipe]
min_depth = -600 # minimum depth in m
max_depth = -3000 # maximum depth in m (restricted by technical mooring limitations)
threshold_AC_DC = 50 # threshold in km at which DC cables are chosen over AC cables
## Temperatures and deltas
T_pinch_WW = 1 # pinch-point temperature difference evaporator in degree Celsius
T_pinch_CW = 1 # pinch-point temperature difference condenser in degree Celsius
# the following parameters have to be multiplied by factor 10 because python cannot loop with floats
del_T_WW_min = 2*10 # minimum temperature difference between warm seawater inlet and outlet
del_T_CW_min = 2*10 # minimum temperature difference between cold seawater inlet and outlet
del_T_WW_max = 5*10 # maximum temperature difference between warm seawater inlet and outlet
del_T_CW_max = 5*10 # maximum temperature difference between cold seawater inlet and outlet
interval_WW = int(0.5*10) # interval used to loop between minimum and maximum warm seawater temperature differences
interval_CW = int(0.5*10) # interval used to loop between minimum and maximum cold seawater temperature differences
del_T_for_looping = [del_T_WW_min,
del_T_CW_min,
del_T_WW_max,
del_T_CW_max,
interval_WW,
interval_CW]
temperatures = [T_pinch_WW,
T_pinch_CW,
del_T_for_looping]
## Heat exchange coefficients
U_evap = 4.5 # nominal overall heat tranfer coefficient evaporator in kW/m2K
U_cond = 3.5 # nominal overall heat tranfer coefficient condenser in kW/m2K
U = [U_evap,U_cond]
## Seawater pipes
length_WW_inlet = 21.598819732666016 # warm seawater inlet pipe length in m, according to Copernicus dataset depth
length_WW_outlet = 60 # warm seawater outlet pipe length in m
length_WW = length_WW_inlet + length_WW_outlet # total length of warm seawater pipe pair
length_CW_inlet = 1062.43994140625 # cold seawater inlet pipe length in m, according to Copernicus dataset depth
# [643.5667724609375,763.3331298828125,902.3392944335938,1062.43994140625] #check for different depth
length_CW_outlet = 60 # cold seawater outlet pipe length in m maybe
length_CW = length_CW_inlet + length_CW_outlet # total length of cold seawater pipe pair
SDR_ratio = 16 # ratio between diameter and thickness
K_L = 100 # pressure drop coefficient for both evaporator and condenser (unitless)
u_pipes = 2.1 # nominal flow velocity in seawater pipes in m/s
u_HX = u_pipes/2 # nominal flow velocity in heat exchangers in m/s
pressure_drop_nom = 100 # maximum pressure in
max_d = 8 # maximum inner seawater pipe diameter in m
max_p = 100 # maximum pressure drop in kPa
pipe_properties = [length_WW,
length_CW,
SDR_ratio,
K_L,
u_pipes,
u_HX,
pressure_drop_nom,
max_d,
max_p]
## Efficiencies (excluding seawater pumps)
eff_isen_turb = 0.82 # isentropic turbine efficiency
eff_isen_pump = 0.8 # isentropic ammonia pump efficiency
eff_pump_NH3_mech = 0.95 # mechanical ammonia pump efficiency
eff_turb_el = 0.95 # electric turbine efficiency
eff_turb_mech = 0.95 # mechanical turbine efficiency
eff_trans = 0 # dummy value and is updated in function "data_processing"
eff_hyd = 0.8 # hydraulic efficiency of seawater pumps
eff_el = 0.95 # electric efficiency of seawater pumps
efficiencies = [eff_isen_turb,
eff_isen_pump,
eff_pump_NH3_mech,
eff_turb_el,
eff_turb_mech,
eff_trans,
eff_hyd,
eff_el]
## Economic assumptions
lifetime = 30 #years
discount_rate = 0.1
crf = discount_rate*(1+discount_rate)**lifetime/((1+discount_rate)**lifetime-1)
availability_factor = 8000/8760
economic_inputs = [lifetime,
crf,
discount_rate,
availability_factor]
return locals()