Device-specific OCPP template improvements (evcc-io#8900)
Browse files Browse the repository at this point in the history
EVBOX Elvi and Wallbox Pulsar Plus / Commander
  • Loading branch information
premultiply authored Jul 13, 2023
1 parent 3b39f00 commit 28d78aa
Show file tree
Hide file tree
Showing 4 changed files with 46 additions and 2 deletions.
20 changes: 20 additions & 0 deletions templates/definition/charger/ocpp-elvi.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -5,5 +5,25 @@ products:
generic: Elvi
params:
- preset: ocpp
- name: meter
type: bool
default: true
description:
de: Hat die Wallbox einen integrierten Zähler verbaut?
en: The charger has an integrated metering device installed?
help:
de: Deaktiveren wenn die Wallbox keinen integrierten Zähler verbaut hat
en: Deactivate if the charger has no integrated metering device installed
- name: meterinterval
advanced: true
type: duration
description:
de: Zählerwerte im Intervall anfordern
en: Interval for requesting metering values
default: 4s
render: |
{{ include "ocpp" . }}
{{- if ne .meter "false" }}
metervalues: Current.Import.L1,Current.Import.L2,Current.Import.L3,Energy.Active.Import.Register,Power.Active.Import,Voltage.L1,Voltage.L2,Voltage.L3
meterinterval: {{ .meterinterval }}
{{- end }}
16 changes: 15 additions & 1 deletion templates/definition/charger/ocpp-pulsarplus.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -2,7 +2,21 @@ template: pulsarplus
products:
- brand: wallbox
description:
generic: Pulsar Plus/ Commander 2/ Copper SB
generic: Pulsar Plus / Commander 2 / Copper SB
requirements:
description:
de: |
Anleitung: https://support.wallbox.com/en/knowledge-base/ocpp-activation-and-setup-guide/
* “OCPP aktivieren” (myWallbox app) bzw. den “OCPP-WebSocket-Verbindung” Schalter (myWallbox Portal) aktivieren
* URL: ws://<evcc-IP-Adresse>:8887/ (Verbindung über das lokale Netzwerk)
* Ladepunktidentität: beliebiger Wert (z.B. die Seriennummer der Box), der als *stationid* verwendet wird
* Passwort: leer lassen
en: |
Setup Guide: https://support.wallbox.com/en/knowledge-base/ocpp-activation-and-setup-guide/
* Switch on “Enable OCPP” (myWallbox app) or enable the “OCPP WebSocket connection” switch (myWallbox Portal)
* URL: ws://<evcc-IP-address>:8887/ (local network connection)
* Charge Point Identity: Custom value (e.g. serial number of charger) which is reused in configuration as *stationid*
* Password: leave empty
params:
- preset: ocpp
render: |
Expand Down
3 changes: 3 additions & 0 deletions templates/docs/charger/elvi_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -5,6 +5,7 @@ render:
- default: |
type: template
template: elvi
meter: true # Deaktiveren wenn die Wallbox keinen integrierten Zähler verbaut hat (Optional)
advanced: |
type: template
template: elvi
Expand All @@ -13,3 +14,5 @@ render:
idtag: '04E6B78921BBA0' # Token-ID welche für die Freischaltung der Ladevorgänge an den Ladepunkt zurückgesendet wird (Optional)
connecttimeout: 5m # Optional
timeout: 2m # Optional
meter: true # Deaktiveren wenn die Wallbox keinen integrierten Zähler verbaut hat (Optional)
meterinterval: 4s # Optional
9 changes: 8 additions & 1 deletion templates/docs/charger/pulsarplus_0.yaml
Original file line number Diff line number Diff line change
@@ -1,6 +1,13 @@
product:
brand: wallbox
description: Pulsar Plus/ Commander 2/ Copper SB
description: Pulsar Plus / Commander 2 / Copper SB
description: |
Anleitung: https://support.wallbox.com/en/knowledge-base/ocpp-activation-and-setup-guide/
* “OCPP aktivieren” (myWallbox app) bzw. den “OCPP-WebSocket-Verbindung” Schalter (myWallbox Portal) aktivieren
* URL: ws://<evcc-IP-Adresse>:8887/ (Verbindung über das lokale Netzwerk)
* Ladepunktidentität: beliebiger Wert (z.B. die Seriennummer der Box), der als *stationid* verwendet wird
* Passwort: leer lassen
render:
- default: |
type: template
Expand Down