Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Fix pullup value for chamber thermistor #6

Open
wants to merge 1 commit into
base: main
Choose a base branch
from

Conversation

himanshugoel2797
Copy link

The documentation claims that the TB thermistor uses a pullup resistor of 4.7 kOhm. This results a highly erroneous reading. Looking at the schematic, a 10kOhm resistor is actually used. Setting the pullup resistor to 10000 in Klipper indeed fixes this reading, so I conclude that this is a documentation error and the pullup should be 10kOhm.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging this pull request may close these issues.

1 participant