CableCheck: allow 0 samples, option to disable wait below 60V at end … (
Browse files Browse the repository at this point in the history
#990)

* CableCheck: allow 0 samples, option to disable wait below 60V at end of cablecheck

Signed-off-by: Cornelius Claussen <cc@pionix.de>

---------

Signed-off-by: Cornelius Claussen <cc@pionix.de>
Co-authored-by: Kai Hermann <kai-uwe.hermann@pionix.de>
  • Loading branch information
corneliusclaussen and hikinggrass authored Dec 13, 2024
1 parent 48581e9 commit dee89f4
Show file tree
Hide file tree
Showing 3 changed files with 58 additions and 33 deletions.
72 changes: 39 additions & 33 deletions modules/EvseManager/EvseManager.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -1547,32 +1547,37 @@ void EvseManager::cable_check() {
// CC.4.1.4: Perform the insulation resistance check
imd_start();

// read out new isolation resistance value
isolation_measurement.clear();
types::isolation_monitor::IsolationMeasurement m;

EVLOG_info << "CableCheck: Waiting for " << config.cable_check_wait_number_of_imd_measurements
<< " isolation measurement sample(s)";
// Wait for N isolation measurement values
for (int i = 0; i < config.cable_check_wait_number_of_imd_measurements; i++) {
if (not isolation_measurement.wait_for(m, 5s) or cable_check_should_exit()) {
EVLOG_info << "Did not receive isolation measurement from IMD within 5 seconds.";
if (config.cable_check_wait_number_of_imd_measurements > 0) {
// read out new isolation resistance value
isolation_measurement.clear();
types::isolation_monitor::IsolationMeasurement m;

EVLOG_info << "CableCheck: Waiting for " << config.cable_check_wait_number_of_imd_measurements
<< " isolation measurement sample(s)";
// Wait for N isolation measurement values
for (int i = 0; i < config.cable_check_wait_number_of_imd_measurements; i++) {
if (not isolation_measurement.wait_for(m, 5s) or cable_check_should_exit()) {
EVLOG_info << "Did not receive isolation measurement from IMD within 5 seconds.";
imd_stop();
fail_cable_check();
return;
}
}

charger->get_stopwatch().mark("Measure");

// Now the value is valid and can be trusted.
// Verify it is within ranges. Fault is <100 kOhm
// Note that 2023 edition removed the warning level which was included in the 2014 edition.
// Refer to IEC 61851-23 (2023) 6.3.1.105 and CC.4.1.2 / CC.4.1.4
if (not check_isolation_resistance_in_range(m.resistance_F_Ohm)) {
imd_stop();
fail_cable_check();
return;
}
}

charger->get_stopwatch().mark("Measure");

// Now the value is valid and can be trusted.
// Verify it is within ranges. Fault is <100 kOhm
// Note that 2023 edition removed the warning level which was included in the 2014 edition.
// Refer to IEC 61851-23 (2023) 6.3.1.105 and CC.4.1.2 / CC.4.1.4
if (not check_isolation_resistance_in_range(m.resistance_F_Ohm)) {
imd_stop();
fail_cable_check();
return;
} else {
// If no measurements are needed after self test, report valid isolation status to ISO stack
r_hlc[0]->call_update_isolation_status(types::iso15118_charger::IsolationStatus::Valid);
}

// We are done with the isolation measurement and can now report success to the EV,
Expand All @@ -1592,18 +1597,20 @@ void EvseManager::cable_check() {
charger->get_stopwatch().mark("Sleep");
}

// CC.4.1.2: We need to wait until voltage is below 60V before sending a CableCheck Finished to the EV
powersupply_DC_off();
if (config.cable_check_wait_below_60V_before_finish) {
// CC.4.1.2: We need to wait until voltage is below 60V before sending a CableCheck Finished to the EV
powersupply_DC_off();

if (not wait_powersupply_DC_below_voltage(CABLECHECK_SAFE_VOLTAGE)) {
EVLOG_error << "Voltage did not drop below " << CABLECHECK_SAFE_VOLTAGE << "V within timeout.";
imd_stop();
fail_cable_check();
return;
}
charger->get_stopwatch().mark("VRampDown");
if (not wait_powersupply_DC_below_voltage(CABLECHECK_SAFE_VOLTAGE)) {
EVLOG_error << "Voltage did not drop below " << CABLECHECK_SAFE_VOLTAGE << "V within timeout.";
imd_stop();
fail_cable_check();
return;
}
charger->get_stopwatch().mark("VRampDown");

EVLOG_info << "CableCheck done, output is below " << CABLECHECK_SAFE_VOLTAGE << "V";
EVLOG_info << "CableCheck done, output is below " << CABLECHECK_SAFE_VOLTAGE << "V";
}

// Report CableCheck Finished with success to EV
r_hlc[0]->call_cable_check_finished(true);
Expand Down Expand Up @@ -1814,7 +1821,6 @@ void EvseManager::imd_start() {
// This returns our active local limits, which is either externally set limits
// or hardware capabilties
types::energy::ExternalLimits EvseManager::get_local_energy_limits() {

types::energy::ExternalLimits active_local_limits;

std::scoped_lock lock(external_local_limits_mutex);
Expand Down
1 change: 1 addition & 0 deletions modules/EvseManager/EvseManager.hpp
Original file line number Diff line number Diff line change
Expand Up @@ -76,6 +76,7 @@ struct Conf {
int hack_sleep_in_cable_check_volkswagen;
int cable_check_wait_number_of_imd_measurements;
bool cable_check_enable_imd_self_test;
bool cable_check_wait_below_60V_before_finish;
bool hack_skoda_enyaq;
int hack_present_current_offset;
bool hack_pause_imd_during_precharge;
Expand Down
18 changes: 18 additions & 0 deletions modules/EvseManager/manifest.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -119,6 +119,24 @@ config:
Enable self testing of IMD in cable check. This is required for IEC 61851-23 (2023) compliance.
type: boolean
default: true
cable_check_wait_below_60V_before_finish:
description: >-
Switch off power supply and wait until output voltage drops below 60V before cable check is finished.
Note: There are different versions of IEC 61851-23:2023 in the wild with the same version number but slightly different content.
The IEC was correcting mistakes _after_ releasing the document initially without tagging a new version number.
Some early versions require to wait for the output voltage to drop below 60V in CC.4.1.2 (last sentence).
Later versions do not have that requirement. The later versions are correct and should be used according to IEC.
Both settings (true and false) are compliant with the correct version of IEC 61851-23:2023.
Set to true when:
- the power supply has no active discharge, and lowering the voltage with no load takes a very long time. In this case
this option usually helps to ramp the voltage down quickly by switching it off. It will be switched on again in precharge.
Also, some EVs switch their internal relay on at a too high voltage when the voltage is ramped down directly from cablecheck voltage to precharge voltage,
so true is the recommended default.
Set to false when:
- the power supply has active discharge and can ramp down quickly without a switch off (by just setting a lower target voltage).
This may save a few seconds as it avoids unnecessary voltage down and up ramping.
type: boolean
default: true
hack_skoda_enyaq:
description: >-
Skoda Enyaq requests DC charging voltages below its battery level or even below 0 initially.
Expand Down