UPDATE: a patch has been released that fixes this issue on PC-DOS 7. See below.
An issue has been discovered with IBM DOS 7 / PC DOS 2000 involving compatibility with V20-based CPUs and INT 1Ah
(functions AH=3
and 5
) support, where due to a bug in the byte-to-BCD conversion code in this version of DOS, date and time are written incorrectly to the real-time clock. This only affects using DOS to set the clock - reading the clock is unaffected.
Possible workarounds are:
- Use the program for that RTC to set the clock initially. DOS 7 can read the clock correctly.
- Use any other version of PC or MS-DOS 3.3 or higher, or FreeDOS.
- Use the patched version of PC-DOS 7 that fixes the
AAD 16
issue: VCFed thread link.